33
462
S e c t i o n 1 . 8
T r o u b l e s h o o t i n g
S e c t i o n O v e r v i e w
This section will cover the following:
Basic troubleshooting.
Common problems/solutions.
Contacting application support.
Product return procedure.
B a s i c Tr o u b l e s h o o t i n g
In the event that your IB462H doesn’t operate properly the first step is to
identify whether the problem is electrical or mechanical in nature. The next
step is to isolate the system component that is causing the problem. As part of
this process you may have to disconnect the individual components that make
up your system and verify that they operate independently. It is important to
document each step in the troubleshooting process. You may need this
documentation to refer back to at a later date, or these details will greatly
assist one of our application engineers in determining the problem should you
need assistance.
Many of the problems that effect motion control systems can be traced to
electrical noise, software errors, or mistakes in wiring.
P r o b l e m S y m p t o m s a n d P o s s i b l e C a u s e s
S y m p t o m
Motor does not move
P o s s i b l e P r o b l e m
No power.
Step Clock is not grounded to opto supply ground.
Unit is in a reset condition.
Current adjust voltage is incorrect or not applied.
Fault condition exists.
Unit is disabled.