background image

 

MDR300-0-0-GB-08 

July 2015 

Page 4 

 

INSTALLATION INFORMATION 

Accessories 

Find the following when unpacking the Multi-discipline Reader: 

  Either an Impro (MDR) Multi-discipline Reader (MDR901-5-0-GB-XX/HRW900-5-0-

GB-XX) housed in an ABS Plastic and 304 Stainless Steel housing.  The Multi-

discipline Reader consists of a Front Cover assembly and a Backing Plate (the 

Backing Plate is attached with a Hexagonal Screw (M3 x 8 mm)).   

  Or an Impro (MDK) Multi-discipline Keypad Reader (MDK901-5-0-GB-XX/ 

HRW901-5-0-GB-XX) housed in an ABS Plastic and 304 Stainless Steel housing.  

  OR a Multi-discipline Junction Box Reader ((HRK900-0-5-GB-XX) / Multi-discipline 

Junction Box Keypad Reader ((HRK901-0-5-GB-XX) housed in a Black, ABS 

Plastic housing.   

 

The Multi-discipline Reader consists of a Front Cover assembly and a Backing 

Plate (the Backing Plate is attached with a Hexagonal Screw (M3 x 8 mm)).   

  One 2-Way Programming Pin. 

  An Allen Key (2 mm). 

  An extra Hexagonal Screw (M3 x 8 mm). 

  An extra Serial Number Label. 

 

The Junction Box Reader consists of a Front Cover and a Backing Plate Assembly 

(the Front Cover is attached with a Combi Screw (6 mm x 2.2 mm)).  The Backing 

Plate Assembly includes 1 m (3.28 ft) of 10-core, 6.2 mm cable.   

  One 2-way Programming Pin. 

  An extra Serial Number Label. 

 

General 

Remember the following when installing the Multi-discipline Readers: 

Maximum Data Communications Distance 

Install the Multi-discipline Readers no further than 150 m (164 yd) from the Host unit.  

The cable individual conductor may be AWG 20 to AWG 22 cross-sectional area should 

not be less than 0.644 mm

2

 (0.0253 in

2

).      

NOTE: 

You can expect a drop in read range on 13.56 MHz Tags if noise exists on 

the Reader’s input supply.  The following good wiring practices lessen noise 

introduction:  Use a well shielded cable with a drain wire, ensure connection 

of the drain wire to a clean Earth point.  Also, install cables away from high 

voltage cabling and other noise (that is wireless equipment, machinery and 

so on) sources. 

Содержание HRK900-0-5-GB Series

Страница 1: ...FARE Tags NOTE HID FeliCa and MIFARE are registered trademarks of HID Global Corporation an ASSA ABLOY Group Brand The Sony Corporation and Koninklijke Phillips Electronics N V respectively Working En...

Страница 2: ...all Indicators on 100 1 2 Wiegand Bus Electrical Interface 0 and 1 Data streams Data Format Tag information 44 bit or 26 bit Wiegand Key information 26 bit Wiegand only Inputs Quantity 4 Type Dry Con...

Страница 3: ...amper HRK900 HRK901 Open Collector Output on Purple Line GND reference on Grey Line NOTE In OEM applications connect the Purple and Grey wires to a Dry Contact Input In Access Portal Systems connectin...

Страница 4: ...amming Pin An Allen Key 2 mm An extra Hexagonal Screw M3 x 8 mm An extra Serial Number Label The Junction Box Reader consists of a Front Cover and a Backing Plate Assembly the Front Cover is attached...

Страница 5: ...face CAUTION You may install Multi discipline Readers in an open environment To do this apply a slanted strip of general purpose black silicone based sealant between the mounting surface and the Backi...

Страница 6: ...015 Page 6 ELECTRICAL CONNECTIONS Connecting the Multi discipline Reader Figure 2 to Figure 7 show typical connections for the Multi discipline Reader Figure 1 Multi Discipline Reader connected to the...

Страница 7: ...MDR300 0 0 GB 08 July 2015 Page 7 Figure 2 Multi discipline Reader Connected to the Impro iTRT...

Страница 8: ...MDR300 0 0 GB 08 July 2015 Page 8 Figure 3 Multi discipline Reader Connected to the IXP20 Controller...

Страница 9: ...MDR300 0 0 GB 08 July 2015 Page 9 Figure 4 Multi discipline Reader Connected to the IXP220 Controller...

Страница 10: ...MDR300 0 0 GB 08 July 2015 Page 10 Figure 5 Multi discipline Reader Connected to the Impro MfT...

Страница 11: ...MDR300 0 0 GB 08 July 2015 Page 11 Figure 6 Multi discipline Reader Connected to the Impro TA or Impro iTA...

Страница 12: ...MDR300 0 0 GB 08 July 2015 Page 12 Figure 7 Multi discipline Reader Connected to the Impro RS or Impro RH...

Страница 13: ...eaders offer four different Output Mode Combinations Select the Output Mode by doing the following 1 On the back of the Multi discipline Reader locate and bridge the two stand alone Pins using the 2 W...

Страница 14: ...e range 00000 to 65535 Wiegand protocol constraints disallow PIN codes from 65536 to 99999 In this case the Status LED turns Red and the Buzzer activates for 2 seconds The Reader can accept 1 to 4 dig...

Страница 15: ...where parity is added NOTE If 00 is entered for the key buffer length then the Key Mode reverts to PIN Mode 3 On acceptance of the setting the Status LED changes to Green 4 If the settings are reject...

Страница 16: ...t The Power on Self test tests the RAM and Flash Checksums If any parameter in the Self test fails the Multi discipline Reader emits a continuous beep for 2 seconds When the Multi discipline Reader pa...

Страница 17: ...2015 Page 17 GUARANTEE OR WARRANTY This product conforms to our Guarantee or Warranty details placed on our Web Site to read further please go to www impro net CE STATUS Models Status MDK901 HRW900 MD...

Страница 18: ...MDR300 0 0 GB 08 July 2015 Page 18 User Notes...

Страница 19: ...MDR300 0 0 GB 08 July 2015 Page 19 User Notes...

Страница 20: ...03 5 0 GB XX HRW902 5 0 GB XX MDR901 5 0 GB XX HRW900 5 0 GB XX MDK900 5 0 GB XX HRW901 5 0 GB XX HRK900 0 5 GB XX HRK901 0 5 GB XX The last two digits of the Impro stock code indicate the issue statu...

Отзывы: