I-Control manual

 

    

                                                                       

page 11 

 

 

This menu concerns the starting times at breakpoint 0 (see text in the screen heading). By pressing the 

 or 

 key, you can browse through the 6 breakpoints. This explanation describes only one break point. The 

remaining breakpoints can be set in the same manner. 

 

Curve mode

 (off – on) 

Using this setting, the operation of the curve is turned on or off. 

OFF

 = The curve control is turned off and the start times are manually set in the menu “Time control”.

  

ON

  = The curve control is turned on and the start times in the menu “time-based control” are set automatically by 

the curve. Manually setting of the start times are no longer possible. 

Note:

 This function is only in the breakpoint 0 menu. 

 

Day number

 (0 to 1000) 

This is the day number on which the breakpoint is to start. From this day number the start times will be set as they 

are selected in the corresponding menu. 

Note:

  This function is only displayed in the breakpoint 1-5 menu. This 

feature is not in the menu of breakpoint 0 as breakpoint 0 is always on day 1, the initial curve. 

 

 

Start time 1

 (00:00 to 23:59 hours)   

At a set time a flush will  start. If you do not wish to use this set start time, set at 00:00. 

 

Repeat day 1

 (1 to 14) 

Flushing can be set on a daily basis or on a given number of days. There are 4 start times. When set at 1, the start 

time is every day; 2 = every 2 days; 3 = every 3 days, etc. The start settings 2 to 4 can be set the same way. 

 

Time/Date 

Select this menu by pressing the 

 key in the main menu. Select “Time/Date” and press the 

 key. The 

functions in this menu are the time and date settings. 

 

Time

 (00:00 to 23:59 hours) 

This is the current time. The I-Control offers a real time clock with backup; the clock functions during power failure. 

With power failure longer than 3-5 days, the backup becomes empty; the clock is to be manually set at the correct 

time when the power is restored. 

 

Date 

(01-01 to 31-12)   

This is the current date.

 

This function has no additional use in the flushing process. 

  

Year

 (2000 to 3000) 

This is the current year. This function has no additional use in the flushing process. 

 

Day counter

 (1 to 1000) 

This is the day number when the curve will be carried out. There is a daily update at 00:00 hours.

 

Note

: At the start 

of a new round this day counter is automatically set at 1. 

 

Medicine calculation 

Select this menu by pressing the 

 key in the main menu. Select “Medicine calculation” and press the 

 

key. Using this menu, the required amount of medicine is calculated. To do this, a various parameters must be 
entered, and the I-Control immediately calculates the amount of medication is to be added to the drinking water. 

 
Nbr animals

 (0 to 999,999) 

Enter the number of birds present in the house. 

 

 

Содержание I-Control

Страница 1: ...IMPEX BARNEVELD BV I Control Manual Edition 1 01 N 13 00 60000...

Страница 2: ...derived from this manual In the context of continuous development and improvement Impex Barneveld BV retains the right to modify this manual without prior notice Any reproduction is prohibited without...

Страница 3: ...ooling Do not turn the power off even when the poultry house is empty Do not use water to clean the I Control The I Control is splash proof not water proof A damaged or defective I Control is dangerou...

Страница 4: ...nding installer program 18 Connection diagrams 19 Electrical connection diagram 19 Flush valve connection diagram 24V internal power supply 20 Flush valve connection diagram External power supply 21 1...

Страница 5: ...ead all settings The main screen gives a summary of the I Control status such as which flushing group is active flushing times etc To change the settings the I Control has a keyboard The numeric keys...

Страница 6: ...ushing starts by the temperature control when the temperature of the water becomes too high Dirt on Flushing dirt The flushing starts by the pollution control when the drinking water becomes too pollu...

Страница 7: ...tcut 5 STOP The following screen is displayed You can choose to stop the I Control completely house is empty or stop temporarily I Control compete stop Press the ENTER key and the I Control will stop...

Страница 8: ...Note 1 Functions showing a measurement such as a measured temperature can neither be selected nor adjusted Note 2 Dependent on the settings of the installer s program some menus and or functions are n...

Страница 9: ...ally starts flushing at the programmed time or when drinking water pollution is detected Te Dir Temperature dirt The I Control automatically starts flushing based on temperature or pollution detection...

Страница 10: ...start time set the timer to 00 00 hours The start time will then be ignored Note When the I Control is still in the waiting time after the last flushing a start time will be skipped over Rep day st 1...

Страница 11: ...menu Start flushing 1 to 100 If pollution exceeds a preset value flushing will start automatically Note Dependent on the settings set by the installer this function may not be displayed Max flushing 1...

Страница 12: ...given number of days There are 4 start times When set at 1 the start time is every day 2 every 2 days 3 every 3 days etc The start settings 2 to 4 can be set the same way Time Date Select this menu by...

Страница 13: ...the amount of water in which the specified amount of medicine is to be dissolved This will be added to the drinking water by the medicine pump Filling water pipes Select this menu by pressing the key...

Страница 14: ...options are English and Dutch with additional languages to be added in the future No of valves 1 to 10 valves This function specifies how many flush groups will be are used The main screen for the use...

Страница 15: ...omputer Determine whether a NO or NC relay is used The main solenoid valve voltage must be originate from the main computer 0 remains connected Note the same transformer or phase is necessary When usi...

Страница 16: ...s the voltage coming from the pollution sensor where 100 pollution must be indicated The reading is divided linearly between the two set input voltages Note This function is only meaningful if the ana...

Страница 17: ...ater system is defective ALARM This alarm activates an external alarm device when water sensor failure occurs WARN This alarm is displayed only as information Supply sens alarm warn With this function...

Страница 18: ...connected to GND therefore no is water detected Water press off on This is the status of the digital input for water pressure detection by a pressure switch OFF The digital input is not connected to G...

Страница 19: ...rd curves are pre set the default setting is 2 minutes Standard curve 1 LAYING HENS Standard curve 2 REARING Standard curve 3 BROILERS LAYING HENS Every morning at 4 30 hours 2 minutes of flushing wit...

Страница 20: ...66 Zero supply voltage Note It is possible to use 115VAC as well as 230VAC voltage Set the switch to the desired voltage Caution If the incorrect voltage is selected the I Control can be irreparably...

Страница 21: ...50 Flush valve 6 51 52 Flush valve 7 53 54 Flush valve 8 55 56 Flush valve 9 57 58 Flush valve 10 Note The flush valves must be 24VAC with a maximal 6VA electric load Important The 4 jumpers with the...

Страница 22: ...be in EXT position See diagram Note An external power supply may be needed if the internal power supply has insufficient power or if another valve voltage other than 24VAC is desired Note The maximum...

Страница 23: ...15V 230V main valve connection diagram I Control 63 64 Main valve relay Potential free max 230VAC 2 Amp Note The relay is potential free A 230V connection has to be made See diagram Note The maximum r...

Страница 24: ...ntial free maximum 230VAC 2 Amp 23 37 24VAC Main valve power supply 24VAC maximum 18VA Note The relay is potential free A 230V connection has to be made See diagram Note The maximum relay load is 230V...

Страница 25: ...ion diagram N o relay external computer 63 64 Main valve relay Potential free maximum 230VAC 2Amp Note The relay is potential free and must be connected parallel to the relay of the external computer...

Страница 26: ...ion diagram N c relay external computer 63 64 Main valve relay Potential free maximum 230VAC 2Amp Note The relay is potential free and must be series connected with the relay of the external computer...

Страница 27: ...nking water circuit temperature sensor 33 GND 20 34 Water supply temperature sensor 34 GND Important The corresponding jumpers must be in TEMP position See diagram Note Always use shielded cable with...

Страница 28: ...to external climate computer Potential free maximum 24VAC DC 100 mA Note Always use shielded cable with a minimum diameter of 0 8 mm for the liter counter and connect the shield to the GND terminal No...

Страница 29: ...imum 50 mA 13 27 GND power supply Note Always use shielded cable with a minimum diameter of 0 8 mm for the dirty water sensor and connect the shield to the GND terminal Note The 12V or 24V power suppl...

Страница 30: ...mportant The jumper of the 0 10V input must be in VOLT position See diagram Note Always use shielded cable with a minimum diameter of 0 8 mm for the dirty water sensor and connect the shield to the GN...

Страница 31: ...50 mA 13 27 GND power supply Note Always use shielded cable with a minimum diameter of 0 8 mm for the pressure switch sensor and connect the shield to the GND terminal Note The 12V or 24V power supply...

Страница 32: ...50 mA 13 27 GND power supply Note Always use shielded cable with a minimum diameter of 0 8 mm for the water detection sensor and connect the shield to the GND terminal Note The 12V or 24V power supply...

Страница 33: ...free maximum 24VAC DC 2 Amp Note Contacts 59 60 are closed when there is no alarm relay is active When there is an alarm contacts 59 60 will be disconnected relay is inactive Note The alarm has a watc...

Страница 34: ...01217 Primabel tubing 5 mtr 7 Drain pipe minimal 50 mm 8 Connection Primabel tubing and drain pipe The installation of the drain pipe and the connection of the Primabel tubing to the drain pipe has to...

Страница 35: ...I Control See lower picture 5 The I control writes all the set functions on the Sd card which is indicated by the flashing ADDR led 6 Thereafter the I control starts the boot program and the update i...

Страница 36: ...z Power consumption Max 30 VA Primary fuse T2A Power supply for sensors 24V DC max 50 mA 12V DC max 50 mA Temperature inputs 2 Measuring range temperature inputs 70 0 C to 130 0 C Alarm relay with wat...

Отзывы: