Wall Mount Installation Detail:
4. Bring wires down and feed through 7/8” hole on top of the hood, at least 8” to 10” long.
5. Remove junction box. (Be sure to comply with all local electrical and safety codes) Remove
Black Tape that holds the Damper Blades in closed position. Attach special length of vent
pipe to the vent opening on top of hood.
6. Hook up electrical wires and secure electrical cover.
7. Install lights and replace filters. For Baffle Filters, install grease tray towards the back of
liner. Take one baffle, slide between steel strips towards the front of the liner and push back
into grease tray grooves, then slide to one side. Insert second baffle the same way and slide
to opposite side. (Grease holes, on bottom of baffle must be inserted into grease tray) Take
Center Panel and slide in towards the front of the liner and push back into grease tray.
TWIN UNITS ONLY—
Transitioning two pipes into one is NOT
recommended. CFMs are reduced by 25% and the Performance warranty will be void.
Содержание WH2000
Страница 17: ......