SINGLE PHASE MICRO-VERTER 0.2 - 2.2KW

Guarantee

Year

Содержание JAGUAR CUB CM Series

Страница 1: ...SINGLEPHASEMICRO VERTER0 2 2 2KW Guarantee Year...

Страница 2: ...lease refer to inside back cover for further details Index 2 FeaturesandConformities 4 Applications 5 SpecificationsandCharacteristics 6 CommonSpecifications 7 TerminalDesignation 8 BasicElectricalCon...

Страница 3: ...0 30 40 50 60 Frequency Hz 20 30 40 50 60 70 0 10 20 30 40 50 60 Frequency Hz PID control function for fans and pumps Complete with a PID control function which can optimise the flow rate of fans and...

Страница 4: ...inverter for confusion free connections Easy to wire control inputs outputs Serial communication RS485 Serial data communication conforming to RS485 through the optional personal computer interface ca...

Страница 5: ...ntrol function lets the inverter optimally control air conditioning systems and various types of fans The CUBCM can also accurately control pump speeds Proportional Integral Derivative Conveyors Adjus...

Страница 6: ...pplied motors Rated with DCR 2 0 3 5 6 5 11 8 17 7 current 4 without DCR 3 9 6 4 11 4 19 8 28 5 Required power supply capacity 5 kVA 0 4 0 7 1 3 2 4 3 6 Braking Torque standard 6 150 100 50 30 DC inje...

Страница 7: ...to 20mA DC Indication Operation mode Output frequency output current PID reference value PID feedback value running or stopping Setting frequency Program mode Function code data code Trip mode Display...

Страница 8: ...selectable 0 frequency All SS1 and SS2 signals are OFF C05 to SS2 select SS1 SS2 0 to 3 different frequencies can be selectable is set by F01 C07 BX Coast to stop BX ON Motor will coast to stop The m...

Страница 9: ...ard direction as set in factory Notes 1 This wiring diagram shows the connection for stopping the inverter or setting frequency through external signals When 1 is set at F01 you can set a frequency by...

Страница 10: ...is set to external operation Frequency setting potentiometer Increases or decreases the frequency Active only when the function code is set to inverter on board pot 1 Turn on the power supply The mon...

Страница 11: ...ing operation stop mode Changes the display between function code Switches the digital display Invalid and data code stores data code and updates then function code Selects the function Selects the fu...

Страница 12: ...to 10 0 min min 0 1 5 0 0 Inactive Trip and alarm when power failure occurs Restart mode after 1 Inactive Trip and alarm when power recovers momentary power failure 2 Active Momentarily stops and rest...

Страница 13: ...frequency Freq 2 Hz 0 1 0 0 setting Freq 3 Hz 0 1 0 0 Control functions of frequency Function Setting range Unit Min Factory Code Name unit setting High Operation time Display the inverter accumulated...

Страница 14: ...running at An alarm remains until constant speed RESET command is issued 1 2 Heat sink over When an abnormal temperature rise is detected in the heat sink the inverter heating protection stops Electr...

Страница 15: ...ions 5 Fig 2 CUB CM220 STOP CUB CM WARNING CAUTION FREQ SET 168 180 6 140 128 6 6 2 5 5 6 TERMINAL 3 M4 TERMINAL 1 M2 5 TERMINAL 2 M4 137 D 2 17 2 72 12 39 6 12 89 2 125 5 128 2 5 168 105 2 6 6 8 66 3...

Страница 16: ...Suppresses radial noise or inductive coupling from output side wiring Effective noise suppression device for long wiring applications such as plant Note When connecting this filter set the carrier fr...

Страница 17: ...65 45 5 2x8 94 M4 1 6 CUB CM150 CMLC150 86 71 80 100 60 40 6x9 110 M4 1 8 CUB CM220 CMLC220 86 71 80 100 70 50 6x9 110 M4 2 6 B A C D H G installation hole 4 places E F EMC filter Inverter mount 4XM4...

Страница 18: ...length 1 bit 2 bit selection possible Frame length Standard frame 16 byte fixed compressed frame 8 or 12 byte Parity None even odd selection possible Error check system Checksum parity framing error W...

Страница 19: ...and user to ensure that the installation of the equipment and the way in which it is operated and maintained complies with the requirements of the Health Safety at Work Act in the United Kingdom and o...

Страница 20: ...range of nominal applied motors shown in the inverter standard specifications table When large starting torque is required or acceleration or deceleration is required in a short time select an inverte...