Max. 45
%
MAX. LENGTH 14400 mm)
The Kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric flange (2)
N° 1 - Wall sealing plate (3)
N° 1 - Aluminium tile (4)
N° 1 - Int./exhaust concentric pipe Ø 60/100 (5)
N° 1 - Fixed half-shell (6)
N° 1 - Mobile half-shell (7)
Vertical kit with aluminium tile
Ø
6
0/100.
Kit assembly
(
Fig. 1
8)
:
install the concentric
fl
ange (2) on the central hole of the boiler,
positioning gasket (1) with the circular projections downwards
in contact with the boiler
fl
ange, and tighten using the screws
contained in the kit.
Installation of the fake aluminium tile: replace the tiles with the
aluminium sheet (4), shaping it to ensure that rainwater runs off.
Position the fixed half-shell (6) on the aluminium tile and insert
the intake-exhaust pipe (5). Fit the
Ø
60/100 concentric terminal
pipe with the male side (5) (smooth) into the
fl
ange (2) up to the
end stop; making sure that the wall sealing plate has been fitted
(3), this will ensure sealing and joining of the elements making
up the kit.
NOTE:
when the boiler is installed in areas where very cold tem-
peratures can be reached, a special anti-freeze kit is available that
can be installed as an alternative to the standard kit.
•
Extensions for vertical kit
Ø
6
0/100
(
Fig. 19
)
.
Th
e kit with this configuration can be extended to a max. straight
vertical length of 14.4 m, including the terminal.
Th
is configura-
tion corresponds to a resistance factor of 100. In this case specific
extensions must be requested.
•
Extensions for
Ø
8
0/125 horizontal kit
(
Fig. 1
7)
.
Th
e kit with this configuration can be extended up to a max.
length of 32 m, including the terminal with grid and excluding
the concentric bend leaving the boiler. If additional components
are assembled, the length equivalent to the maximum allowed
must be subtracted. In this case the special extensions must be
requested.
1.15 CONCENTRIC VERTICAL KIT INSTALLATION.
•
Type C configuration, sealed chamber and fan assisted.
Concentric vertical intake and exhaust kit.
Th
is vertical terminal
is connected directly to the outside of the building for air intake
and
fl
ue gas exhaust.
N.B.:
the vertical kit with aluminium tile enables installation on terraces
and roofs with a maximum slope of 45
%
(approx 25°) and the height
between the terminal cap and half-shell (374 mm for
Ø
60/100 and 260
mm for
Ø
80/125) must always be observed.