1.7  ELECTRIC CONNECTION. 

The appliance has an IPX5D protection degree, 

electrical safety of the appliance is reached only 

when it is connected properly to an efficient 

earthing system as specified by current safety 

standards.

Attention:

 Immergas S.p.A. declines any respon-

sibility for damage or physical injury caused by 

failure to connect the boiler to an efficient earth 

system or failure to comply with the reference 

standards.

•  Open the control panel connections compart-

ment (Fig. 1-4).

  To carry out electrical connections, all you have 

to do is open the connections compartment as 

follows.

- Remove the front panel (Fig. 3-15b).
- Remove the cover (b fig. 1-4).
  1)  Loosen the two screws (a).
  2)  Press the two hooks on the cover (b).
  3)  Remove the cover (b) from the control 

panel (c).

-  At this point, it is possible to access the terminal 

board (d).

Also ensure that the electrical installation cor-

responds to maximum absorbed power specifi-

cations as shown on the boiler data nameplate. 

Boilers are supplied complete with an “X” type 

power cable without plug. The power supply 

cable must be connected to a 230V ±10% / 

50Hz mains supply respecting L-N polarity and 

earth connection; 

, this network must also 

have a multi-pole circuit breaker with class III 

over-voltage category.

To protect from possible dispersions of DC 

voltage one must provide a type A differential 

safety device.

When replacing the power supply cable, contact 

a qualified company (e.g. the the Authorised 

After-Sales Technical Assistance Service). The 

power cable must be laid as shown (Fig. 1-3).

In the event of mains fuse replacement on the 

P.C.B., use a 3.15A quick-blow fuse. For the 

main power supply to the appliance, never use 

adapters, multiple sockets or extension leads.

Installation with system operating at direct 

low temperature.

 The boiler can directly supply 

a low-temperature system by setting the flow 

temperature adjustment range “t0” and “t1” 

(Par. 3.12). In this situation it is good practice 

to insert a relevant safety kit (optional) made up 

from a thermostat (with adjustable temperature). 

Execute connection to terminal boards 14 and 15, 

eliminating jumper X70 (Fig. 3-2). The thermo-

stat must be positioned on the system flow pipe 

at a distance of at least 2 metres from the boiler.

1.8  REMOTE CONTROLS AND 

ROOM CHRONO-THERMOSTATS 

(OPTIONAL).

The boiler is prepared for the application of room 

chrono-thermostats or remote controls, which 

are available as optional kits (Fig. 1-5).

All Immergas chrono-thermostats are connected 

with 2 wires only. Carefully read the user and 

assembly instructions contained in the acces-

sory kit.
• On/Off Immergas digital chrono-thermostat. 

The chrono-thermostat allows:

  - set two room temperature value: one for 

daytime (comfort temperature) and one for 

nighttime (reduced temperature);

  - set a weekly program with four daily switch 

on and switch off times;

  -  select the required operating mode from the 

various possible alternatives:

  • manual operation (with adjustable tempera-

ture).

  • automatic operation (with set programme).

  • forced automatic operation (momentarily 

changing the temperature of the automatic 

programme).

  The chrono-thermostat is powered by two 1.5V 

LR 6 type alkaline batteries.

•  Comando Amico Remoto Remote Control De-

vice 

V2

 (CAR

V2

) with climate chrono-thermostat 

function. In addition to the functions described 

in the previous point, the CAR

V2

 panel enables 

the user to control all the important informa-

tion regarding operation of the appliance and 

the heating system with the opportunity to 

easily intervene on the previously set parame-

ters, without having to go to where the appli-

ance is installed. The panel is provided with 

self-diagnosis to display any boiler functioning 

anomalies. The climate chrono-thermostat 

incorporated into the remote panel enables 

the system flow temperature to be adjusted to 

the actual needs of the room being heated, in 

order to obtain the desired room temperature 

with extreme precision and therefore with 

evident saving in running costs. The CAR

V2

 is 

fed directly by the boiler by means of the same 2 

wires used for the transmission of data between 

the boiler and device.

Important:

 if the system is subdivided into zones 

using the relevant kit, the CAR

V2

 must be used 

with its climate thermostat function disabled, i.e. 

it must be set to On/Off mode.

Comando Amico Remoto Remote Control 

V2

 

or On/Off chrono-thermostat electrical con-

nections (Optional)

The operations described 

below must be performed after having removed 

the voltage from the appliance.

 Any thermostat 

or On/Off environment chrono-thermostat must 

be connected to clamps 40 and 41 eliminating 

jumper X40 (Fig. 3-2). Make sure that the On/

Off thermostat contact is of the “clean” type, i.e. 

independent of the mains voltage, otherwise the 

P.C.B. would be damaged. Any Comando Amico 

Remoto Remote Control 

V2

 must be connected to 

clamps 44 and 41 eliminating jumper X40 on the 

P.C:B., paying attention not to invert the polarity 

in the connections (Fig. 3-2).

Important:

 if the Comando Amico Remo-

to Remote Control 

V2

 or any other On/Off 

chrono-thermostat is used, arrange two separate 

lines in compliance with current regulations 

regarding electrical systems. No boiler pipes 

must ever be used to earth the electric system or 

telephone lines. Ensure elimination of this risk 

before making the boiler electrical connections.

Содержание VICTRIX 24 TT 2 ERP

Страница 1: ...VICTRIX 24 TT 2 ERP IE Instruction and warning book 1 039151ENG ...

Страница 2: ......

Страница 3: ...ons specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits established by the Law Installation and maintenance must be performed in compliance with the regulations in force according to the manufacturer s instructions and by an authorised company which has sp...

Страница 4: ...enance 21 2 2 General warnings 21 2 3 Control panel 21 2 4 Using the boiler 22 2 5 Troubleshooting 23 2 6 Information menu 25 2 7 Boiler shutdown 25 2 8 Restoring central heating system pressure 25 2 9 System draining 25 2 10 Anti freeze protection 25 2 11 Case cleaning 25 2 12 Decommissioning 25 3 Boiler commissioning initial check 26 3 1 Boiler Hydraulic diagram 26 3 2 Wiring diagram 27 3 3 Remo...

Страница 5: ...ssiblewater and flue removal connections Keep all flamma ble objects away from the appliance paper rags plastic polystyrene etc Do not place household appliances underneath the boiler as they could be damaged if the safety valve intervenes if the drain trap is blocked or if there are leaks from the hydraulic connec tions otherwise the manufacturer cannot be held responsible for any damage caused t...

Страница 6: ...lowed scrupulously regarding the percentage neces sary with respect to the minimum temperature at which the system must be kept An aqueous solution must be made with potential pollution class of water 2 EN 1717 2002 or local regula tions in force The materials used for the central heating circuit of Immergas boilers withstand ethylene and propylene glycol based antifreeze liquids if the mixtures a...

Страница 7: ... condensa tion module warranty before making the boiler connections carefully wash the heating system pipes radiators etc with special pickling or descaling products to remove any deposits that could compromise correct boiler operation A treatment of the heating and water system water is required in compliance with the tech nical standards in force in order to protect the system and the appliance ...

Страница 8: ... and assembly instructions contained in the acces sory kit On Off Immergas digital chrono thermostat The chrono thermostat allows set two room temperature value one for daytime comfort temperature and one for nighttime reduced temperature set a weekly program with four daily switch on and switch off times select the required operating mode from the various possible alternatives manual operation wi...

Страница 9: ...l temperature increases in order to adjust the heat supplied to the system according to the change in external temperature The ex ternal probe always operates when connected regardless of the presence or type of room chrono thermostat used and can work in combi nation with Immergas chrono thermostats The correlation between system flow temperature and external temperature is determined by the posi...

Страница 10: ...owed corresponds to the resistance encountered with the maximum allowed pipe length for each type of Terminal Kit This information allows calculations to be made to verify the possibility of setting up various flue configurations Positioning the gaskets black for green range flue systems Position the gasket cor rectly for bends and extensions Fig 1 8 gasket A with notches to use for bends gasket B...

Страница 11: ...0 Intake and Exhaust 16 3 m 2 5 Intake m 18 7 Exhaust m 4 9 m 7 7 Exhaust m 13 6 Concentric vertical intake exhaust terminal Ø 60 100 Intake and Exhaust 9 m 1 4 Intake m 10 3 Exhaust m 2 7 m 4 3 Exhaust m 7 5 Pipe Ø 80 m 1 Intake 0 87 m 0 1 Intake m 1 0 Exhaust m 0 4 m 0 4 m 0 5 Exhaust 1 2 m 0 2 Exhaust m 1 0 Complete intake terminal Ø 80 m 1 Intake 3 m 0 5 Intake m 3 4 Exhaust m 0 9 m 1 4 Intake...

Страница 12: ...esent in the kit positioning the relevant gaskets Engage the 90 Ø 80 bend with the male end smooth in the female end with lip seal of the Ø 80 flange unit until it stops Introduce the gasket making it run along the bend Fix it using the sheet steel plate and tighten by means of the straps present in the kit making sure to block the 4 gasket flaps Fit the male end smooth of the exhaust terminal int...

Страница 13: ...nd external wall sealing plate have been fitted this will ensure sealing and joining of the elements making up the kit Extensions for Ø 60 100 horizontal kit Fig 1 13 The kit with this configuration can be extended up to a max 12 9 horizontal m in cluding the terminal with grid and excluding the concentric bend leaving the boiler This configurationcorrespondstoaresistancefactor of 100 In this case...

Страница 14: ...smooth into the flange 2 up to the stop making sure that the wall sealing plate has been fitted 3 this will ensure sealing and joining of the elements making up the kit NOTE when the boiler is installed in areas where very cold temperatures can be reached a special anti freeze kit is available that can be installed as an alternative to the standard kit Extensions for vertical kit Ø 60 100 Fig 1 17...

Страница 15: ...to needs and replace it with the flange 3 positioning the gasket 2 already present in the boiler and tighten using the supplied self threading screws Fit the male end smooth to the bends 5 in the female end of the flanges 3 and 4 Fit the intake terminal 6 with the male side smooth in the female side of the bend 5 up to the end stop ensuring that the internal and external wall sealing plates are fi...

Страница 16: ...while the external pipe must be fitted on the adaptor until it stops 1 N B to encourage the removal of possible condensate forming in the exhaust pipe tilt the pipes towards the boiler with a minimum slope of 1 5 Mount the cover A complete with adaptor 1 and caps 6 on the wall and assemble the flue system to the ducting system N B version Ø 125 only before assembly check the gaskets are in the rig...

Страница 17: ...e can be installed inside buildings in 23 or B53 mode in this case all technical rules and national and local regulations in force must be complied with type B open chamber boilers must not be installed in places where commercial artisan or industrial activities take place which use products that may develop volatile vapours or substances e g acid vapours glues paints sol vents combustibles etc as...

Страница 18: ...d be between 6 5 and 8 5 Check the maximum content of chlorides which should be less than 250 mg l N B for quantities and methods of use of wa ter treatment products refer to the instructions provided by their manufacturer 1 22 SYSTEM FILLING Once the boiler is connected proceed with system filling via the filling cock Fig 1 29 and 1 3 Filling is performed at low speed to ensure release of air bub...

Страница 19: ...is kit is very useful for maintenance because it allows to empty just the boiler without having to empty the entire system Moreover the version with filter preserves the functioning characteristics of the boiler thanks to its inspectionable filter System zone control unit kit on request If the heating system is to be divided into several zones max three in order to interlock them with separate adj...

Страница 20: ...c hot water flow switch 8 System expansion vessel 9 Air gas mixer 10 Flow probe 11 Manual air vent valve 12 Ignition detection electrode 13 Sample points air A flue gas F 14 Flue probe 15 Burner cover 16 Safety flow probe 17 Condensation module 18 Fan 19 System pressure switch 20 Vent valve 21 Boiler circulator pump 22 3 bar safety valve 23 3 way valve motorised 24 By pass 25 3 bar safety valve dr...

Страница 21: ...es some fundamental rules to be observed do not touch the appliance with wet or moist parts of the body do not touch when bare foot never pull electrical cables or leave the appli ance exposed to weathering rain sunlight etc the appliance power cable must not be re placed by the user if the cable is damaged switch off the ap pliance and solely contact an authorised company to replace it if the app...

Страница 22: ... the outlet water is hot enough or if there is Solar ignition delay time the boiler does not switch on the D H W with drawal symbol appears on the display along with the flashing solar function symbol When the water supplied by the solar system is at a temperature lower than what is set or if the Solar ignition delay time has elapsed the boiler switches on At this point the solar function symbol w...

Страница 23: ...t Press the Reset button 1 20 Parasite flame block This occurs in the event of a leak on the detection circuit or anomaly in the flame control unit Press the Reset button 1 24 Push button control panel anomaly The board detects an anomaly on the pushbutton panel If normal conditions are restored the boil er restarts without having to be reset 1 29 Flue probe anomaly The board detects an anomaly on...

Страница 24: ...urrent on the gas valve is detected The boiler does not start 1 80 P C B malfunction block This occurs in the event of malfunctions of the P C B that controls the valve Press the Reset button 1 84 Combustion anomaly power reduction in progress A low supply pressure is detected on the gas line As a result the appliance power is limited and the anomaly is reported If normal conditions are restored t...

Страница 25: ... frequently filling must be car ried out with suitably treated water to eliminate hardness that can cause lime scale 2 11 CASE CLEANING Use damp cloths and neutral detergent to clean the boiler casing Never use abrasive or powder detergents 2 12 DECOMMISSIONING In the event of permanent shutdown of the boiler contact an authorised company for the suitable procedures and also ensure the electri cal...

Страница 26: ...er check that the intake and or exhaust terminals are not blocked ensure activation of all adjustment devices check the production of domestic hot water check sealing efficiency of water circuits check ventilation and or aeration of the instal lation room where provided If even only a single safety check offers a negative result do not commission the system 3 1 BOILER HYDRAULIC DIAGRAM Key 1 Gas v...

Страница 27: ... Flue probe B24 Safety flow probe CAR V2 Comando Amico Remoto remote control V2 optional E3 Ignition and detection electrode M1 Boiler circulator pump M20 Fan M30 Three way valve R5 Domestic hot water temperature trim mer R6 Central heating temperature trimmer S4 Domestic hot water flow switch S5 System pressure switch S20 Room thermostat optional T1 Boiler PCB transformer T2 Ignition transformer ...

Страница 28: ...s of material blocking the flow of condensate Heat exchanger clogged This may be caused by the drain trap being blocked Check that there are no residues of material blocking the flow of condensate Noise due to air in the system Check opening of the special air vent valve cap Part 20 Fig 1 29 Make sure the system pressure and expansion vessel pre charge values are within the set limits The factory ...

Страница 29: ... position Fig 3 5 and press the Reset button for about 8 seconds until the chimney sweep function is activated then press the summer winter button within 3 seconds Nominalheatoutput with the function active the boiler carries out the procedures required to calibrate the appliance at the nominal heat output At this stage the display features flashing icons summer winter stand by and the operating t...

Страница 30: ... fast calibration is used after having set the type of flue in menu F which once altered causes anomaly 72 N B before carrying out complete calibration ensure that all the requirements indicated in paragraphs 1 21 and 1 22 have been fulfilled N B to access this function it is crucial that there are no active requests for central heating or DHW production In the event of anomaly 62 or 72 see parag ...

Страница 31: ...heck that there are no obstructions in the flue system Different values to those indicated in the previous tables indicate a flue system malfunction especially a flue system with excessive load losses or ob structed system 3 12 PROGRAMMING THE P C B The boiler is prepared for possible programming of several operation parameters By modifying these parameters as described below the boiler can be ada...

Страница 32: ...can be configured 0 Off 1 Main zone control 2 General alarm 3 CH phase active 4 External gas valve power supply 5 Do not use on this boiler model 6 Do not use on this boiler model 7 Do not use on this boiler model 0 7 1 P4 Relay 2 optional The boiler is set up for functioning with the relay P C B optional which can be configured 0 Off 1 General alarm 2 CH phase active 3 External gas valve power su...

Страница 33: ... changing the operating mode in order to quickly and comfortably satisfy an additional request for domestic hot water 0 100 sec onds step 10 sec 2 t5 Central heating ignitions timer The boiler has electronic timing which prevents the burner from ignit ing too often in central heating mode 0 600 sec onds step 10 sec 18 t6 Central heating ramp timer In the heating stage the boiler performs an igniti...

Страница 34: ... water is the same or greater than that set by the DHW selector switch the boiler does not switch on 3 14 CHIMNEY SWEEP FUNCTION When activated this function forces the boiler to variable output for 15 minutes In this state all adjustments are excluded and only the safety thermostat and the limit ther mostat remain active To activate the chimney sweep function press the Reset button 2 until activa...

Страница 35: ... boiler pressure gauge the expansion vessel pressure is at 1 0 bar Check that the system static pressure with system cold and after refilling the system by means of the filling valve is between 1 and 1 2 bar Visually check that the safety and control devices have not been tampered with and or short circuited Check the condition and integrity of the elec trical system and in particular supply volta...

Страница 36: ...d Fig 3 15a 1 Loosen the two screws a 2 Press the hooks inwards which block the lower grid b 3 Remove the grid b Front panel Fig 3 15b 4 Remove the cover caps c and loosen screws d 5 Pull the front panel e towards you and release it from its lower seat Front Fig 3 15c 6 Loosen the two screws g 7 Pull the front f slightly towards you 8 Release front f from pins h pulling it towards you while pushin...

Страница 37: ... INSTALLER USER MAINTENANCE TECHNICIAN Control panel Fig 3 15d 9 Press the hooks on the side of the control panel i 10 Tilt the control panel i towards you Sides Fig 3 15e 11 Loosen screws k of side fastening j 12 Remove the sides by extracting them from their rear seat Rif X Ref X ...

Страница 38: ... 63 1 20 14 0 12040 54 1 52 1 12 13 0 11180 50 1 41 1 04 12 0 10320 45 1 30 0 96 11 0 9460 40 1 19 0 88 10 0 8600 35 1 08 0 80 9 0 7740 31 0 97 0 72 8 0 6880 26 0 87 0 64 7 0 6020 21 0 76 0 56 6 0 5160 16 0 65 0 48 5 0 4300 11 0 54 0 40 4 0 3440 6 0 43 0 32 3 0 2580 1 0 32 0 24 3 23 COMBUSTION PARAMETERS G20 G31 Supply pressure mbar mm H2 O 20 204 37 377 Gas nozzle diameter mm 5 15 5 15 Flue flow ...

Страница 39: ...Off 80 60 C 0 01 2 4 Central heating circuit max operating pressure bar 3 Maximum heating temperature C 90 Adjustable heating temperature max operation field C 20 85 System expansion vessel total volume l 5 8 Expansion vessel factory set pressure bar 1 0 Appliance water content l 1 9 Head available with 1000 l h flow rate kPa m H2 O 37 2 3 8 Hot water production useful heat output kW kcal h 23 6 2...

Страница 40: ...Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat input Qn max CH maximum heat input Pn min Minimum heat output Pn max Maximum heat output PMS Maximum system pressure PMW Maximum domestic hot water pressure D Specific flow rate TM Maximum operating temperature NOx Class NOx Cl...

Страница 41: ... load elmin 0 012 kW Ignition burner energy consumption Pign 0 000 kW In standby mode PSB 0 005 kW Emissions of nitrogen oxides NOX 25 mg kWh For mixed central heating appliances Stated load profile XL Domestic hot water production efficiency ηWH 85 Daily electrical power consumption Qelec 0 220 kWh Daily gas consumption Qfuel 22 677 kWh Contact information IMMERGAS S p A VIA CISA LIGURE 95 42041 ...

Страница 42: ...he of boiler Supplementary heat pump From fiche of heat pump Solar contribution and Supplementary heat pump Select smaller value Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C From fiche of heat pump The energy efficiency of the package of products provided far in this fiche may not correspond to its actual energy efficiency once installed in a building as ...

Страница 43: ...The energy efficiency of the package of products provided far in this fiche may not correspond to its actual energy efficiency once installed in a building as the efficiency is influenced by fur ther factors such as heal loss in the distribution system and the dimensioning of the products in relation to building size and characteristics Seasonal space heating energy efficiency of package Seasonal ...

Страница 44: ...r contribution From fiche of solar device 1 I 2 1 1 x I 10 x II III I Auxiliary electricity 3 G F E D C B A A A A 27 27 27 28 27 27 27 28 30 30 30 32 33 34 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL 3 2 3 2 The energy efficiency of the package of products provided far in this fiche may not correspond to its actual energy efficiency once ins...

Страница 45: ...ency under colder and warmer climate conditions Colder 0 2 x Warmer 0 4 x Declared load profile Solar contribution From fiche of solar device 1 ___ 2 1 1 x ___ 10 x ___ ____ ____ Auxiliary electricity 3 G F E D C B A A A A 27 27 27 28 27 27 27 28 30 30 30 32 33 34 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL 3 2 3 2 The energy efficiency of t...

Страница 46: ...46 ...

Страница 47: ...47 ...

Страница 48: ...immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 039151ENG rev ST 002102 003 10 16 Inglese per IRLANDA IE ...

Отзывы: