32
3-1
3
INSTALLATION
3.1 CHOICE OF THE
INSTALLATION PLACE.
Floor strength
• Withstands a load of 400 kg at least (surface below water heater)
The installation area shall be suitable for protection index IP 24, as per provision CEI 64-8
Non-ducted or semi-ducted configuration
Ducted configuration
Type of installation room
Examples of rooms
Volume of room where air is extracted
Temperature of water heater installation
room
Air intake temperature
Ceiling height
Surface area required
• Unheated room, characterised by temperature
exceeding 5°C and preferably insulated from
the home's heated rooms.
• Recommended room= basement or semi-base-
ment, room where the temperature is higher
than 10°C all year round.
• garage, boiler room ( with the exception of
rooms where type B generators are installed),
basement floor, ironing room, etc.
• Volume > 20 m
3
• 5°C to 43°C except for water heater operation.
• 5°C – 43°C.
• > 2.00 m.
• (625+400) x 700 (L x P) (Fig. 3-1).
• Essential for surface to be level.
•
Room at least frost-free.
Recommended room = living space (heat loss
from the water heater is not wasted), close to
outside walls.
• Do not install close to sleeping areas, because
of the noise produced.
• laundry room, cellar, cupboard in entrance hall,
etc.
• /
• 5°C – 43°C.
• 5°C – 43°C.
• > 2.00 m.
• 680 x 700 (L x P) (Fig. 3-1).
• Essential for surface to be level.
"Non ducted" configuration
"Non ducted" configuration
"Non ducted" configuration
"Ducted" configuration
Caution:
failure to comply with recommended installation procedures, especially a room volume below the 20
3
minimum, may significantly reduce
system performance.