INSTALLATION
BOILER
1.1 INSTALLATION
RECOMMENDATIONS.
The Mini Eolo 24 3E boiler has been designed
for wall mounted installation only; for heating
environments and production of domestic hot
water for domestic use and similar purposes.
The place of installation of the appliance and
relative Immergas accessories must have suitable
features (technical and structural) such to allow
(always in safety, efficiency and easy conditions):
- installation (according to the provisions of
technical legislation and technical regulations);
- maintenance operations (including scheduled,
periodic, routine, special);
- removal (to outdoors in the place for
loading and transporting the appliances
and components) as well as the eventual
replacement of those with appliances and/or
equivalent components.
The wall surface must be smooth, without any
protrusions or recesses enabling access to the
rear part. They are NOT designed to be installed
on plinths or floors (Fig. 1-1).
By varying the type of installation the
classification of the boiler also varies, precisely:
-
Boiler type B22,
if installed without the 2
intake caps and with the top cover kit.
-
Boiler type C,
if installed using concentric
pipes or other types of pipes envisioned for
the sealed chamber boiler for intake of air and
expulsion of fumes.
Only professionally enabled heating/plumbing
technicians are authorised to install Immergas
gas appliances. Installation must be carried
out according to regulation standards, current
legislation and in compliance with local
technical regulations and the required technical
procedures. Installation of the Mini Eolo 24 3E
boiler when powered by LPG must comply with
the rules regarding gases with a greater density
than air (remember, as an example, that it is
prohibited to install plants powered with the
above-mentioned gas in rooms where the floor
is at a lower quota than the average external
country one). Before installing the appliance,
ensure that it is delivered in perfect condition;
if in doubt, contact the supplier immediately.
Packing materials (staples, nails, plastic bags,
polystyrene foam, etc.) constitute a hazard and
must be kept out of the reach of children. If the
appliance is installed inside or between cabinets,
ensure sufficient space for normal servicing;
therefore it is advisable to leave clearance of at
least 3 cm between the boiler casing and the
vertical sides of the cabinet. Leave adequate
space above the boiler for possible water and flue
removal connections.
Keep all flammable objects away from the
appliance (paper, rags, plastic, polystyrene, etc.).
Do not place household appliances underneath
the boiler as they could be damaged if the safety
valve intervenes with obstructed conveying
system (the safety valve must be conveyed away
by a draining funnel), or if there are leaks from
the hydraulic connections; on the contrary, the
manufacturer cannot be held responsible for any
damage caused to the household appliances. For
the aforementioned reasons, we recommend not
placing furnishes, furniture, etc.under the boiler.
In the event of malfunctions, faults or incorrect
operation, turn the appliance off immediately
and contact a qualified technician (e.g. the
Immergas Technical After-Sales Centre, which
has specifically trained staff and original spare
parts) Do not attempt to modify or repair the
appliance alone. Failure to comply with the above
implies personal responsibility and invalidates
the warranty.
• Installation Standards:
- This boiler can be installed outdoors in a
partially protected area. A partially protected
area is one in which the appliance is not
exposed to the direct action of the weather
(rain, snow, hail, etc..).
N.B.:
a partially protected location is one in
which the appliance is not exposed to the direct
action of the weather (rain, snow, hail, etc..).
- Installation in places with a fire risk is
prohibited (for example: garages, closed
parking stalls), gas appliances and relative flue
ducts, flue exhaust pipes and combustion air
intake pipes.
- Installation is prohibited on the vertical
projection of the cooking surface.
- Installation is also prohibited in places/
environments that constitute common parts
of office condominiums such as stairs, cellars,
entrance halls, attics, lofts, escape routes,
etc. if they are not located inside technical
compartments under the responsibility of
each individual building and only accessible
to the user (for the features of the technical
rooms, see the regulation in force.
Attention
: wall mounting of the boiler must
guarantee stable and efficient support for the
generator.
The plugs (standard supply) are to be used only in
conjunction with the mounting brackets or fixing
template to fix the appliance to the wall
; they only
ensure adequate support if inserted correctly
(according to technical standards) in walls made
of solid or semi-hollow brick or block. In the
case of walls made from hollow brick or block,
partitions with limited static properties, or in any
case walls other than those indicated, a static test
must be carried out to ensure adequate support.
N.B.: the hex head screws supplied in the blister
pack are to be used exclusively to fix the relative
mounting bracket to the wall.
These boilers are used to heat water to below
boiling temperature in atmospheric pressure.
They must be attached to a heating system
suitable for their capacity and voltage.
YES
NO