1.10 SOLAR COLLECTORS.

The installation of a heating solar collector 

requires analysis of a range of issues (installa-

tion area, positioning, inclination angle, etc.), of 

which depend on the performances the collector 

will be able to supply once started.

It is therefore important to contact a an author-

ised company to check the various parameters 

installation.

Installation precautions:

-  Before installing the collector, proceed with an 

installation area check, ensure the installation 

of the collector can withstand atmospheric 

agents: wind and snow.

- The collector can be positioned based on the 

roofs conditions (flat or leaning) or in a predis-

posed adjustable structure. Under no circum-

stances can the collector be positioned with the 

collector glass facing downwards which is the 

cause of the malfunctions and damages. 

- before starting the operating system, the solar 

collector must be covered to protect the ab-

sorber from overheating and the operator from 

scalding. The system must only be filled when 

the hydraulic system of the collector has been 

assembled and cannot be started before it has 

been possible to eliminate the heat generated 

from the solar collector. 

- Be careful to not force or put the connection 

fittings under excessive traction to avoid 

damaging them and the internal parts of the 

collector.

-  During handling use appropriate personal pro-

tective equipment (e.g. gloves etc.) and avoid 

transporting the collector from the connection 

fittings.

- Provide an appropriate earthing system con-

nection and any lightning and surge protection 

systems to safeguard any electric devices. In 

the event these systems are already present, 

the Immergas solar system must be connected 

to the existing lightning protection system by 

a qualified firm, in compliance with the legisla-

tion in force, which must issue a declaration of 

conformity.

HEAD LOSSES GRAPHICS.

FLAT COLLECTOR

VACUUM COLLECTOR

Mass flow rate [kg/h]

Mass flow rate [kg/h]

Pr

es

su

re d

ro

p [m

ba

r]

Pr

es

su

re d

ro

p [m

ba

r]

Содержание 3.027832

Страница 1: ...V2 HEATING SOLAR PANELS PACKS IE Instruction booklet and warning 1 041485ENG...

Страница 2: ......

Страница 3: ...ls within the dimensional limits established by the Law Installation and maintenance must be performed in compliance with the regulations in force according to the manufacturer s instructions and by a...

Страница 4: ...Inox Sol 500 V2 12 1 9 Inox Sol 500 Lux V2 13 1 10 Solar collectors 14 1 11 Control devices unit 16 1 12 Circulation unit 17 1 13 Hydraulic connection CP4XL flat collectors 18 1 14 Hydraulic connectio...

Страница 5: ...ti legionella heat treatment of the Immergas storage tank activated by the specific function present on the predisposed thermoregulatory systems during this stage the temperature of the water inside t...

Страница 6: ...it 2 N 1 individual solar circulation unit 3 N 1 18 l expansion vessel 4 N 1 6 bar safety valve 5 N 1 system probe and venting unit 6 N 1 mixing valve 7 frame and brackets for roof installation Key A...

Страница 7: ...l unit 2 N 1 double circulation solar unit 3 N 1 35 l expansion vessel 4 N 1 6 bar safety valve 5 N 1 probe unit and system venting 6 N 1 mixer valve 7 frame and brackets for roof installation Key A H...

Страница 8: ...1 electronic control unit 2 N 1 single circulation solar unit 3 N 1 18 l expansion vessel 4 N 1 6 bar safety valve 5 N 1 probe unit and system venting 6 N 1 mixer valve 7 N 1 200 litre storage tank i...

Страница 9: ...tor CSV14 1 N 1 electronic control unit 2 N 1 double circulation solar unit 3 N 1 35 l expansion vessel 4 N 1 6 bar safety valve 5 N 1 probe unit and system venting 6 N 1 mixer valve 7 N 1 200 litre s...

Страница 10: ...N 1 electronic control unit 2 N 1 single circulation solar unit 3 N 1 18 l expansion vessel 4 N 1 6 bar safety valve 5 N 1 probe unit and system venting 6 N 1 mixer valve 7 N 1 300 litre storage tank...

Страница 11: ...ctors CSV14 1 N 1 electronic control unit 2 N 1 double circulation solar unit 3 N 1 35 l expansion vessel 4 N 1 6 bar safety valve 5 N 1 probe unit and system venting 6 N 1 mixer valve 7 N 1 300 litre...

Страница 12: ...electronic control unit 2 N 1 single circulation solar unit 3 N 1 35 l expansion vessel 4 N 1 6 bar safety valve 5 N 1 probe unit and system venting 6 N 1 mixer valve 7 N 1 500 litre storage tank in s...

Страница 13: ...CSV14 1 N 1 electronic control unit 2 N 1 double circulation solar unit 3 N 1 80 l expansion vessel 4 N 1 6 bar safety valve 5 N 1 probe unit and system venting 6 N 1 mixer valve 7 N 1 500 litre stora...

Страница 14: ...the solar collector must be covered to protect the ab sorber from overheating and the operator from scalding The system must only be filled when the hydraulic system of the collector has been assembl...

Страница 15: ...ef Opening surface W m2 K2 0 0161 K angle incidence 50 0 95 Heating capacity ceff 5 72 Maximum working pressure bar 10 Average flow l min 1 25 TECHNICAL FEATURES CSV Name Vacuum collector Dimensions m...

Страница 16: ...installation ensure that the connection cable to the electric network and the probe cables remain separated The control unit is equipped with 3 relay to which to connect users such as pumps valves etc...

Страница 17: ...for flow rate reading 15 Non return valve thermometer and cock 16 Degasser 17 Solar collector inlet 18 Boiler towards output 1 12 CIRCULATION UNIT The pump unit allows to connect the storage tank to...

Страница 18: ...six collectors in series using the connection kits additional collectors N B when mounting the fittings including the air vent valve apply teflon or other material with similar characteristics N B bef...

Страница 19: ...s supplied by Immergas The following can be connected to maximum six collectors in series using the connection kits additional collectors N B when mounting the fittings including the air vent valve ap...

Страница 20: ...front and rear halves b drill two holes 8 on the wall in correspond ence with the holes on the supporting plate c fix the supporting plate to the wall by placing the rear half of the insulation casing...

Страница 21: ...he liquid contained in the solar circuit 1 20 FILLING SYSTEM The system can only be filled when the system is completely assembled any working residues have been eliminated that cause obstructions and...

Страница 22: ...tive operations ensuring among other things that water supply is disconnected and the solar collector is covered At the end of its service life the appliance must not be disposed of like normal househ...

Страница 23: ...ing checks and maintenance should be performed at least once a year Visually check for water leaks or oxidation from on connections Check visually that the safety and control devices have not been tam...

Страница 24: ...mmergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 041485ENG rev ST 003408 000 11...

Отзывы: