The drinking water temperature can be adjusted between approx. 5°C and 12°C.
The adjustment is done by turning the knob underneath the unit cover.
ATTENTION ! Before opening the unit unplug the power supply !
Turning the knob clockwise will lower the water temperature
Turing it counterclockwise all the way will turn the cooling compressor off.
A new temperature setting will not show immediatly. Leave the unit some time
to respond.
Remark :
the best carbonation values (approx. 6 gr. CO
2
per liter, depending on mains water pressure)
is achieved, when setting the unit to lowest temperature (knob position = 7)
12.
12.
Adjustment of water temperature
Adjustment of water temperature
Page 35
13.
13.
Daily Checks
Daily Checks
It is recommended to discharge the first 0,5 liters every morning upon the start of unit use. This has a positive effect on
the carbonisation and temperature of the following drinks.
Check on a daily basis :
- that the CO
2
empty LED indication is not illuminated, otherwise replace the empty CO
2
bottle with a new one
- if external damages or defects are visible, e.g. water or gas leaks.
In case you notice defects, immediatly turn off the water, power and gas supply and contact your local service technician !
Содержание Pearlmax3
Страница 17: ...15 15 Dokumentation Betriebsbuch Seite 1 Dokumentation Betriebsbuch Seite 1 Seite 16...
Страница 18: ...Seite 17 15 15 Dokumentation Betriebsbuch Seite 2 Dokumentation Betriebsbuch Seite 2...
Страница 19: ...Seite 18 15 15 Dokumentation Betriebsbuch Seite 3 Dokumentation Betriebsbuch Seite 3...
Страница 40: ...Page 39 17 17 Sanitization Logbook Sanitization Logbook...
Страница 41: ...18 Konformit 18 Konformit tserkl tserkl rung Declaration of conformity rung Declaration of conformity Page 40...