BPGS PNEUMATIC GRIPPER SYSTEM
User Manual
BIM-BPGSM-0519 Rev 1 | For Technical Assistance: 800-442-4622
9
2. Double Blank
1) To program the sensor for a particular material thickness, apply air to the gripper and grip on the material
thickness which is to be used for the particular job. With an object such as a small Allen wrench, press the
button until the Red LED(s) corresponding to the material range of the job lights as shown on the label.
2) Verify calibration:
(a.) Close the gripper with no material between the pads. The LED(s) should be off.
(b.) Close the gripper on a single blank of material. The Red LED(s) corresponding to you material range should
be on.
INSTALLING AN IN-PAD SENSOR
1. If an In-Pad Sensor is to be installed, it goes on top of the side plate assembly. Wrap sensor cable through
holder and align holes on side plate. Clean and apply Red Loctite 262 or equivalent to 2X M5 X 10mm SHCS
and thread thru sensor into side plate. Tighten both SHCS to 36in-lb.
2. Shim is only used for part numbers listed. If a shim is to be used on an angle pad, smaller tabs go on the
narrow side of the pads.
Small Tabs
BPGS10RXXXXX1XXX
BPGS10FXXXXX1XXX
BPGS10CXXXXX1XXX
BPGS10DXXXXX4XXX
BPGS10EXXXXX7XXX
BPGS10SXXXXX1XXX
BPGS10TXXXXX4XXX
BPGS10UXXXXX7XXX
BPGS10VXXXXX1XXX
BPGS10WXXXXX4XXX
BPGS10YXXXXX7XXX