14
English
4.3 Operation without DMX controller
The following operating modes are available:
1. Static light: user-defined colour
Select the menu item
: The spotlight will
radiate light in the colour most recently set via
this menu item (mixed colour from red, green
and blue) .
To set the colour, call up
and adjust
the submenu items
(red),
(green)
and
(blue) one after another (
= off,
= maximum brightness) until you obtain
the desired colour .
2. Static light: preset colour
Select the menu item
: The spotlight will
radiate light in the colour most recently selected .
To select the colour, call up
and select
one of the 25 colours available .
3. Light program
Select the menu item
: The light program
most recently selected will start .
To select a program, call up
and select
the desired program from the four submenu
items:
stroboscope in the colour set in
cross-fading between colours
change of colour
sound-activated mode (sound-activated
change of colour)
To set the program, call up the correspond-
ing submenu item and set the desired value
…
(slow … fast speed for
,
,
; low … high sound sensitivity for
) .
Master/slave mode (refer to chapter 3.2.2)
Select the desired operating mode (
,
or
) for the master unit only .
On all slave units, select the menu item
or
(the setting of these menu items is irrelevant
in this case) .
4.4 Additional menu functions
After setting these functions, select the desired
operating mode again .
Temperature-controlled power limitation
The spotlight is equipped with a power limitation .
It will protect the spotlight against overheating
when the internal temperature is too high . When
this function has been activated (
), the power
consumption of the LED will be reduced to 50 %
when the temperature reaches 80 °C . The power
consumption will rise to 100 % again when the
temperature has dropped to 58 °C .
In the 10-channel DMX mode, the function can be
deactivated or activated via channel 10 (
☞
table,
page 13) .
Note:
The power limitation function is independent of
the temperature-controlled ventilation system .
LED response time
When
has been selected, the LED will imme-
diately respond when the brightness setting has
been changed . To simulate the slow response of a
conventional lamp, select the desired setting from
the four settings
(slightly slow response) …
(slowest response) .
In the 10-channel DMX mode, the response
time is adjusted via channel 10 (
☞
table, page 13) .
Default settings
To reset the menu to the default settings, select
the setting
and press ENTER to confirm .
After the reset, the menu item
is called up
(setting
) .
5 Specifications
Data protocol: . . . . . . . . . . DMX 512
Number of
DMX channels: . . . . . . . . . 5 or 10 (selectable)
Light source: . . . . . . . . . . . RGB COB LED
Power consumption: . . . . 100 W
Beam angle: . . . . . . . . . . 60°
Stroboscope frequency: . . 20 Hz max .
DMX connections: . . . . . . XLR, 3 poles
Pin configuration: . . . . . . pin 1 = ground
pin 2 = DMX−
pin 3 = DMX+
Ambient temperature: . . . 0 – 40 °C
Power supply: . . . . . . . . . . 230 V/ 50 Hz
Power consumption: . . . . . 160 VA
Dimensions (W × H × D): . 150 × 220 × 245 mm
(without bracket)
Weight: . . . . . . . . . . . . . . 1 .5 kg
Subject to technical modification .
All rights reserved by MONACOR
®
INTERNATIONAL GmbH
& Co. KG. No part of this instruction manual may be repro-
duced in any form or by any means for any commercial use.