11
English
2 . The wire which is coloured blue must be con-
nected to the terminal which is marked with
the letter N or coloured black .
3 . The wire which is coloured brown must be
connected to the terminal which is marked
with the letter L or coloured red .
Warning – This appliance must be earthed.
If the unit is to be put out of operation
definitively, take it to a local recycling
plant for a disposal which is not harmful
to the environment .
3 Installation
3.1 Mounting / Setting up the spotlight
•
To prevent heat accumulation inside the unit,
always position the unit so that sufficient air cir-
culation will be ensured during operation . Never
cover the air vents of the housing .
•
Always keep a minimum distance of 50 cm to
the illuminated surface .
Mounting the spotlight:
Use the double bracket
to mount the spotlight, e . g . by means of a solid
mounting screw or a suitable support (e . g . C hook)
on a crossbar . To align the spotlight, release the
two locking screws of the bracket, incline the spot-
light as desired and fasten the screws again .
WARNING
Install the spotlight safely and ex-
pertly . When the spotlight is installed
at a place where people may walk
or sit under it, additionally secure it
(e . g . by means of a safety rope on
the bracket; attach the safety rope
so that the maximum falling distance
of the unit will not exceed 20 cm) .
Setting up the spotlight:
Release the two lock-
ing screws of the double bracket so that it can be
adjusted . Fold out the two parts of the bracket
underneath the spotlight and use them as a stand .
Then fasten the screws again .
3.2 Control connections
The spotlight is equipped with two 3-pole XLR
control connections:
a DMX input (DMX IN), a DMX output (DMX OUT) .
For operation with a DMX controller or in the
master / slave mode, the XLR connections are used
to interconnect the units . For connection, use spe-
cial cables for DMX signal transmission (e . g . cables
of the CDMXN series) . For cable lengths exceeding
150 m or when controlling more than 32 units, it
is generally recommended to insert a DMX level
matching amplifier (e . g . SR-103DMX) .
3.2.1 Connection to a DMX controller
To connect multiple DMX-controlled units to a DMX
controller, proceed as follows (also refer to fig . 1):
1) Connect the DMX output of the controller to
the DMX input of the first DMX-controlled unit .
2) Connect the DMX output of the first DMX-con-
trolled unit to the DMX input of the second
DMX-controlled unit . Proceed in the same way
to connect the output of the second unit to the
input of the third unit etc . until all DMX-con-
trolled units have been connected in a chain .
3) To prevent interference in signal transmission,
in case of long cables or a multitude of units
connected in series, terminate the DMX output
of the last unit in the chain with a 120 Ω resistor
(> 0,3 W): Connect a DMX terminating plug
(e . g . DLT-123) to the output jack .
3.2.2 Master/slave mode
Synchronous operation of multiple PARC-100E / RGB
spotlights is also possible without a DMX control-
ler . One unit (master) will control the other units
(slaves) . Connect the units in a chain according to
chapter 3 .2 .1 (also refer to fig . 2) .
➀
➁
DMX-controlled
unit
DMX-controlled
unit
DMX-controlled
unit
DMX-controlled
unit
DMX controller
DMX
output
DMX
output
DMX
output
DMX
output
DMX
output
DMX
input
DMX
input
DMX
input
DMX
input
DMX terminating plug
(if required)
DMX
output
DMX
output
DMX
output
DMX
output
DMX
output
DMX
input
DMX
input
DMX
input
DMX
input
DMX terminating plug
(if required)
Slave unit
Slave unit
Slave unit
Slave unit
Master unit