background image

7.3.2 Changing the program password

To change the password for starting the

program:
1) Call up the menu item “Tools

±

Change

Software Password”.

2) A new window will be displayed. In the

field “Enter Old Password:”, enter the

current password (the factory-set pass-

word is “monacor”).

3) A new window will be displayed. In the

field “Enter New Password:”, enter the

new password.

4) A new window will be displayed. In the

field “Confirm New Password:”, enter

the new password again to confirm it.

Make sure to remember the password!

7.3.3 Demo mode

Even when no unit is connected to the com-

puter, it is possible to create a virtual unit

for demonstration purposes. To do so, call

up the menu item “Tools

±

Enter Demo

Mode”.

Various virtual units with the additional

designation “DEMO…” will be added to the

list. As for real units, the button

can be

used to call up the configuration window

(

fig. 7).

To remove the virtual units from the list,

call up the menu item “Tools

±

Leave Demo

Mode”.

7.3.4 Firmware update

The control program and the unit must be

equipped with matching firmware versions

to ensure smooth communication. If the

version of the control program is newer, the

firmware (operating system) of the units

may be updated via the control program.

With this update, all settings saved on the

units will be lost. To keep the settings, save

them on the computer (

chapter 8.11)

before starting the update.

Note:

Firmware updates are performed at your

own risk. After the update, the functions of the unit

may differ from those described in the instruction

manual.

CAUTION:

Switch off the signal sources or

reduce their output level to avoid an unex-

pectedly high volume after the settings

have been reset.
To update the firmware of a unit, call up the

menu item “Tools

±

Enable Update”. In the

list, the symbol

will appear after the

units. Units with a grey symbol cannot be

updated (e. g. because the units are

already equipped with the current firmware

version or because the access rights do not

allow for an update).

Note:

Units connected via the USB interface can-

not be updated. To update these units, connect

them via the Ethernet interface.

Units with an orange symbol can be up-

dated:
1) Click the button

in the row of the cor-

responding unit.

2) A message will appear which informs

you that it is not allowed to switch off the

unit or to interrupt the connection during

the multi-step update process. If the

update fails, it must be started again.

Click [OK] to start the update, or click

[Cancel] to cancel it.

3) Upon completion of the update, another

message will appear. Confirm this mes-

sage.

To hide the update symbols in the list

again, call up the menu item “Tools

±

Dis-

able Update”.

Note:

Resetting to the factory settings will also

affect the network settings and the passwords of

the unit, i. e. it may initially not be possible to

access the unit via the computer.

When the unit is in the access level “Devel-

opment”, the firmware may also be up-

dated via the menu of the configuration

window (Hardware

±

Firmware Update).

7.3.5 Exiting the program

To exit the program, call up the menu item

“File

±

Quit” or close the program window.

8 Configuring the DSP

To configure the signal processor of a unit,

click the button

(

figs. 4, 5) in the

appropriate row of the list.

The configuration window (fig. 7) with

the view MAIN for the unit selected will

appear. The colour field on the left-hand

side, next to LINK

, will indicate the con-

nection status of the unit. When the colour

field is green, a data connection has been

established. A red field will indicate that the

connection has been interrupted and that it

is not possible to modify settings. If the user

tries to make changes, an error message

will appear.

Any settings changed on the screen will

be instantly transferred to the unit provided

that a data connection exists. The settings

can be saved as presets on the computer

and in the unit (

chapter 8.2). In addition,

it will be possible to define if the subwoofer

system, when being switched on, is to load

a specific preset or the state it was in when

switched off (

chapter 8.10).

If allowed by the access rights of the

current preset (

chapter 8.7.3.), the

buttons on the left side bar can be used to

go to the other views (X-OVER, IN 1/2,

OUT 1/2/3) [figs. 8 – 10]. To return to the

main view, click the button MAIN.

8.1 Signal path

Figure 6 shows a block diagram of the path

a signal takes through the subwoofer sys-

tem. Starting at the two inputs, the signals,

after analog/digital conversion, pass the in-

put amplifier (GAIN), a high pass filter

(HPF), a low pass filter (LPF), the 10-band

sound adjustment (PEQ), the signal delay

(DELAY), a dynamic range compressor

(COMPRESSOR) and the level limiter

(LIMITER). For each of the three output

channels, an individual mixed signal can be

created from the two input signals

processed. The mixed signal will have the

same processing options as the signals of

the input channels and additionally the

phase inversion option (PHASE INVERT);

after processing, the mixed signal will be

routed to digital/analog conversion. The

output channel OUT 1 will be routed to the

internal low-frequency speakers via two

class D power amplifiers. The output chan-

nels OUT 2 and OUT 3 will lead to the line

level outputs “OUT-2” and “OUT-3”.

The parameters of the blocks shown

can be set in the views MAIN, X-OVER,

IN 1/2 and OUT 1/2/3. Some of the pa-

rameters can be accessed via several

views.

Note:

The setting options available depend on the

access rights of the current access level (

chap-

ter 6.1). To be able to make all settings, go to the

access level “Development” when calling up the

control program for the first time. This level allows

you to define the access rights and passwords for

the other access levels as required by the users

who will operate the unit (

chapter 8.7).

Attention!

Combined with the control program, the

signal processor is an effective tool for

making very detailed but also major

changes to the transmission properties of

the PA system.

Therefore, each modification to the

parameters should be performed with

care and expertise. At the worst, extreme

changes to the settings may damage the

speakers.

18

E

n

g

li

sh

Содержание MEGA-215DSP

Страница 1: ...mmer 09 0110 ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS BEDIENUNGSANLEITUNG INSTRUCTION MANUAL Aktiver PA Subwoofer mit DSP Active...

Страница 2: ...2 1 2 3 4 5 6 7 8 9 10 11 12 Beispielkonstellation Example constellation...

Страница 3: ...ndby 12 8 10 Einschalt Preset festlegen 12 8 11 Sichern Zur ckladen aller Presets 12 9 Steuerung ber einen Tabletcomputer 12 10 Technische Daten 13 Stereo PA Amplifier with DSP These instructions are...

Страница 4: ...ann keine Haftung f r durch Fehlbedienung oder durch einen Defekt entstandene Datenverluste und deren Fol gesch den bernommen werden 3 Einsatzm glichkeiten Diese aktive Subwoofer Lautsprecherbox ist g...

Страница 5: ...nter Password oder ber das Steuerprogramm Men punkt Hardware Enter Password Kap 8 7 1 Die folgende Tabelle zeigt die Zugriffsebe nen in absteigender Rangfolge und die zugeh rigen Passw rter Passwortvo...

Страница 6: ...Netzwerktechnik Kenntnisse erforderlich Hinweis Bei einer direkten Verbindung der Sub wooferbox mit einem Computer kann die Verwen dung eines Crossover Kabels oder eines entspre chenden Adapters erfo...

Страница 7: ...ools Change Soft ware Password aufrufen 2 Im angezeigten Fenster in das Feld Enter Old Password das bisherige Passwort eingeben vom Werk vorein gestellt ist monacor Verbindung mit dem Computer stehen...

Страница 8: ...lopment befindet 7 3 5 Programm beenden Zum Beenden des Programms den Men punkt File Quit aufrufen oder das Pro grammfenster schlie en 8 DSP konfigurieren Zur Konfiguration des Signalprozessors in de...

Страница 9: ...verbunden Rot nicht verbunden F r den Wechsel zu einem anderen Ger t dieses im Listenfeld w hlen UNIT NAME Name des Ger ts kann durch berschreiben ge ndert werden GAIN Regler zur Lautst rkeeinstellung...

Страница 10: ...zeigefelder f r den Verst rkungswert Kurvendarstellung des Amplituden Fre quenzgangs Beschreibung Kap 8 3 GAIN Regler zur Lautst rkeeinstellung f r den entsprechenden Ausgang daneben Pegel Anzeige dar...

Страница 11: ...ner Kopplung der Ausg nge 2 und 3 werden nur zwei Filterkurven angezeigt Die Grenzfrequenzen der Filter wer den durch dreieckige Marken oberhalb der Kurve dargestellt Durch Verschie ben einer Marke mi...

Страница 12: ...ungen ber das jeweilige Men Preset Access Rights Locked Access Rights User Access Rights und Admin Access Rights vorgenommen werden 8 8 Locked State Um in die unterste Zugriffsebene Locked State zu ge...

Страница 13: ...1 m Max Nennschalldruck 133 dB Nenneingangsspannung 1 2 V Max Eingangsspannung 11 V Eingangsimpedanz 24 k Ausg nge OUT 2 3 3 5 V 1 k symmetrisch Stromversorgung 230 V 50 Hz Leistungsaufnahme max 2400...

Страница 14: ...woofer speaker system is equally designed for fixed installations and for mobile applications e g on stage or in discotheques It is used as a low frequency complement to an existing amplification syst...

Страница 15: ...sword or via the control program menu item Hard ware Enter Password chapter 8 7 1 The following table shows the access levels in descending order and the corre sponding passwords Factory set passwords...

Страница 16: ...to larger computer networks Internet Network technology expertise is indispensable for the correct connection setup Note A direct connection of the subwoofer sys tem to a computer may require the use...

Страница 17: ...e symbol to change the mode of the unit The symbol will be grey when the connection is interrupted When a unit is switched on and a new connection is being established an additional row Startup with t...

Страница 18: ...ation window Hardware Firmware Update 7 3 5 Exiting the program To exit the program call up the menu item File Quit or close the program window 8 Configuring the DSP To configure the signal processor...

Страница 19: ...nnected Red not connected To change to a different unit select the unit from the list UNIT NAME name of the unit over write the name to change it Controls GAIN to adjust the volume of the two inputs t...

Страница 20: ...n quality factor and band width Input Indication field GAIN for filter boost attenuation High pass filter HPF input indication field for the cut off frequency enter values in Hz Off 20 Hz High pass fi...

Страница 21: ...ossovers are easy to identify When the outputs 2 and 3 are linked only two filter curves are shown The cut off frequencies of the filters are represented by triangular markings above the curve To chan...

Страница 22: ...t make the settings desired via the cor responding menu Preset Access Rights Locked Access Rights User Access Rights and Admin Access Rights 8 8 Locked State Call up the menu item Hardware Lock Unit t...

Страница 23: ...2400 W Speakers Number 2 Size 38 cm 15 Type CELESTION FTR15 4080FD Frequency range 28 300 Hz typical application range can be modified via DSP configuration SPL 98 dB 1 W 1 m Max SPL 133 dB Rated inpu...

Страница 24: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1714 98 01 11 2015...

Отзывы: