background image

 

Monitoring Box  

IMA-BOX 

 

 

 

 

 

 

 

1

 

 

FR 

FR 

EN 

Installation_Manual_Monitoring_Box_

IMA-BOX

_VA.4 

 

 

 

Monitoring Box 

 

IMA-BOX 

 

 

 

 

Version externe / External version 

 

 

 

 

 

Содержание IMA-BOX

Страница 1: ...Monitoring Box IMA BOX 1 FR FR EN Installation_Manual_Monitoring_Box_IMA BOX_VA 4 Monitoring Box IMA BOX Version externe External version...

Страница 2: ...ages Description de la modification Modification description Auteur Author A 1 A 2 A 3 A 4 08 12 16 12 12 16 24 02 17 20 04 17 X All All All R daction initiale Initial Drafting Navigation firmware 1 5...

Страница 3: ...Monitoring Box IMA BOX 3 FR FR EN Installation_Manual_Monitoring_Box_IMA BOX_VA 4 Monitoring Box installation...

Страница 4: ...ication IMEON Manager 11 6 3 1 Home Accueil 11 6 3 2 Manager Gestion des flux Onglet flow 13 6 3 3 Manager Gestion du stockage Onglet Battery 15 6 3 4 Manager Enregistrement onglet SCAN 16 6 3 5 Manag...

Страница 5: ...ff rents connecteurs disponibles sur la Monitoring Box garantie son volution dans le temps Cette documentation d crit l installation de la Monitoring Box en version boitier externe ATTENTION Le d bran...

Страница 6: ...vec les accessoires suivants Accessoires Nom Photo Alimentation 12V C ble de communication USB RS232 Communication Monitoring Box USB vers onduleur RS232 Antenne WiFi Connecteur Relais RS485 Gigabit E...

Страница 7: ...nitoring_Box_IMA BOX_VA 4 4 Sch ma g n ral d installation Ce sch ma d crit une installation standard avec une Monitoring Box externe IMEON Batteries USB RS232 CAN Communication CAN pour batteries auli...

Страница 8: ...s rez le c ble de communication batterie sur le port CAN de la Monitoring Box et le port appropri de la batterie Cas du lithium uniquement 2 Ins rez le c ble USB RS232 sur un des ports USB de la Monit...

Страница 9: ...er l interface Web de l IMEON MANAGER Cette interface est accessible par r seau filaire ou sans fil Proc dez de la mani re suivante 6 1 1 Par ETHERNET 1 Dans votre r seau local s lectionnez le p riph...

Страница 10: ...2 S lection du SSID IMEON et connexion avec la cl BonjourImeon 3 Une fois connect allez dans votre navigateur WEB et saisissez l adresse http 192 168 3 6 6 2 Acc s l interface 6 2 1 CONNEXION avec le...

Страница 11: ...ur dans votre pays Seul le logiciel IMEON MANAGER doit tre utilis pour le param trage de l onduleur Toute autre application n est pas compatible et peut nuire au fonctionnement de l onduleur Quatre li...

Страница 12: ...e graphique interactif d autoconsommation sur une heure Etat du parc batterie tat de chargement instantan de la batterie SOC Tension Battery voltage Courant Battery current Consommation et stockage jo...

Страница 13: ...ion sur le connecteur GRID CONNECTION L utilisation de la batterie n est pas possible avec ce mode Autoriser l injection vers le r seau Allow to feed in to the grid Permet d interdire ou d autoriser l...

Страница 14: ...ence il faut indiquer 00 00 00 00 Mode veille LCD LCD standby mode Permet de r gler la temporisation pour la mise en veille du r tro clairage de l IMEON Possibilit s 0 30 60 300 600 en secondes ou kee...

Страница 15: ...ce du r seau public doit obligatoirement tre inf rieur ou gal celui avec le r seau Le SOC a un impact important sur la dur e de vie du stockage SOC faible dur e de vie r duite mais quantit d nergie ut...

Страница 16: ...rie en fonctionnement Battery Off Battery disconnected c ble d croch ou batterie teinte Error Communication IMEON erreur de communication avec l IMEON 6 3 4 Manager Enregistrement onglet SCAN Permet d...

Страница 17: ...Box_IMA BOX_VA 4 6 3 5 Manager Erreur onglet ERRORS Permet d enregistrer dans un fichier les erreurs actuelles et anciennes enregistr es par l IMEON export possible au format Excel ou CSV 6 3 6 Timeli...

Страница 18: ...Si le WiFi est sur OFF seul l Ethernet permet de se connecter l onduleur Appuyez sur List connection pour scanner la liste des r seaux disponibles puis appuyez sur Select pour s lectionner le r seau c...

Страница 19: ...ologie de batteries utilis e Plomb ou Lithium Proc dez de la mani re suivante 6 4 1 Batterie Lithium R f rez vous la documentation de la batterie du fabricant si n cessaire 1 En mode Installateur alle...

Страница 20: ...la batterie de OFF ON 5 D s que le message Battery ready to start s affiche appuyez sur le bouton ON de l interface WEB 6 D s l apparition du message Battery operating le syst me est op rationnel et l...

Страница 21: ...ns de consommation d lectricit du b timent communiqu es par le compteur associ Ces informations ainsi que des algorithmes internes l IMEON optimiseront l utilisation des diff rentes sources d nergie d...

Страница 22: ...igurer l onduleur via le logiciel IMEON MANAGER WEB onglet gestion des flux Manager Flow 1 S lectionner le mode de fonctionnement Smart Grid Function mode 2 Appuyer sur le bouton OK correspondant 3 L...

Страница 23: ...pression successive sur le bouton affiche successivement 1 Puissance active instantan e en kW 2 Puissance r active instantan e en kVAr 3 Volt amps instantan s en KVA 4 Total kW kVArh kVA 5 Fr quence...

Страница 24: ...soci Quitter permet de fermer l application IMEON Manager Permet d activer la batterie Permet de lancer l enregistrement des v nements Permet d arr ter l enregistrement des v nements Copie les donn es...

Страница 25: ...Monitoring Box IM2015 EBO1A Installation_Manual_Monitoring_Box_IMA BOX_VA 4...

Страница 26: ...Monitoring Box IMA BOX 26 Installation_Manual_Monitoring_Box_IMA BOX_VA 4 Monitoring Box Installation...

Страница 27: ...in 33 6 2 2 User login 33 6 3 Using the IMEON Manager Web 34 6 3 1 Home 34 6 3 2 Manager flow 36 6 3 3 Manager Battery 37 6 3 4 Manager SCAN 39 6 3 5 Manager ERRORS 40 6 3 6 Timeline 40 6 3 7 Local in...

Страница 28: ...calability insurance for the future This documentation describes the Monitoring Box installed as an external module CAUTION Un plugging the Battery to Monitoring Box communication cable so interruptin...

Страница 29: ...ded with the following accessories Accessories Name Photo Power supply 12V Communication cable USB RS232 Communication cable Monitoring Box USB to inverter RS232 WiFi antenna Relay Connector RS485 Gig...

Страница 30: ...al_Monitoring_Box_IMA BOX_VA 4 4 Installation overview This scheme describes a standard installation with an external Monitoring Box IMEON Batteries USB RS232 CAN CAN communication for IMEON compatibl...

Страница 31: ...wired as follows on the IMEON side 1 Plug the communication battery cable on port CAN of the Monitoring Box and plug the other part on the correct port of the battery For lithium battery only 2 Plug...

Страница 32: ...tem is up and running you may access the web based interface of the system using wireless or wired connection Proceed as follows 6 1 1 Wired Ethernet connection 1 In your home network find IMEON IP ad...

Страница 33: ...ID and connect using BonjourImeon password 3 In your Web browser go to the URL address http 192 168 3 6 6 2 Login 6 2 1 Installer login Login installer local Password Installer_P4SS 6 2 2 User login A...

Страница 34: ...y software other than IMEON MANAGER WEB is not authorized by IMEON ENERGY and may cause irreversible damage affecting the operation of IMEON inverter There are four main tabs Home Manager Flow Battery...

Страница 35: ...IMA BOX_VA 4 Self use Interactive one hour self consumption chart Battery condition Battery charging status in real time SOC Battery voltage Battery current Daily Consumption and energy stored Interac...

Страница 36: ...out grid On Grid Inject the totality of the solar production in the GRID CONNECTION connector Using batteries is not possible with this mode Allow feed in to the grid Allow to block or authorize injec...

Страница 37: ...00 00 LCD stand by mode Allows setting the timing of the screen light of the IMEON Possibilities 0 30 60 300 600 seconds or keep alight Date Time Allows adjusting the internal clock of IMEON Date form...

Страница 38: ...unt of energy Note for lead batteries only In order to secure the DC BUS stability in case of a high grid voltage the cut off voltage of the end of discharge may be not reached See below values of cut...

Страница 39: ...ed for AC GRID phases 1 2 and 3 Smart Meter if present AC OUTPUT phases 1 2 and 3 BATTERY and PV INPUT PV 1 and PV 2 AC GRID Voltage V BATTERY Voltage V Power W State of charge Current A Current A Fre...

Страница 40: ...lation_Manual_Monitoring_Box_IMA BOX_VA 4 6 3 5 Manager ERRORS Log of errors detected by the inverter during operation Possible to export Excel and CSV format 6 3 6 Timeline Timeline allows to record...

Страница 41: ...Intelligence reboot restore the factory settings Default settings or log out from the manager Logout 1 WiFi Press List connection to scan the list of available SSID and press Select to connect If you...

Страница 42: ...out Press Logout to exit from manager 6 4 Battery configuration The settings may vary depending on the battery technology that is in use Lead or Lithium Proceed as follows 6 4 1 Lithium Batteries Refe...

Страница 43: ...tery State OFF then ON 5 As soon as the Battery ready to start message appears switch the Battery State to ON position 6 A soon as the Battery operating message appears the system is operational and a...

Страница 44: ...ns and IMEON internal algorithms will optimize the use of the different energy sources PV production battery bank in order to increase the total efficiency of the PV system There is a monophase smart...

Страница 45: ...e inverter 6 5 3 Inverter configuration Configure the inverter via IMEON MANAGER WEB tab Manager Flow 1 Select the function mode Smart Grid 2 Press the button OK 3 The symbol should be displayed on th...

Страница 46: ...sing of the button selects a new range 1 Instantaneous Active Power in kW 2 Instantaneous Reactive Power in kVAr 3 Instantaneous Volt amps in KVA 4 Total kW kVArh kVA 5 Frequency and Power Factor tota...

Страница 47: ...ut the parameter Allows to exit the Web Manager Allows to activate and deactivate the battery Allows to record the faults and events Allows to stop the recording of the faults and events Allows to cop...

Страница 48: ...x IMA BOX 48 Installation_Manual_Monitoring_Box_IMA BOX_VA 4 Adresse Address 10 rue Amiral Romain Desfoss s 29200 BREST FRANCE Tel 33 1 84 17 51 15 www imeon energy com IMEON ENERGY FRANCE Votre nergi...

Отзывы: