4. Installation recommendation 

 

Access Station Micro has been developed for indoor and outdoor operation.  
 
For temporary location, the base station is perfectly stable sitting on a table, a desk 
or a shelf. For permanent  installation,  we recommend  using  the mounting kits for 
long-term fixation. 

 

For  outdoor  operation,  the  adjunction  of  sealing  cover  is  mandatory  to  ensure 
waterproofness (see §4.4).  

4.1. 

Coexistence with another RF equipment 

 
As  any  radio  equipment,  Access  station  micro  should  be  installed  with  proper 
decoupling  precaution  versus  other  radio  transmitters.  Should  the  quantified 
decoupling  recommendation  listed  below  be  infringed,  the  access  station  micro 
would enter degraded operation, including coverage reduction. 
Decoupling protection is usually expressed in dB, however for practical reasons, 
this guide presents decoupling recommendation in terms of physical separation. 

 

Co-location  of  access  station  micro  on  Telco  site

  or 

with  third  party  SRD/ISM 

systems operating on the same band is forbidden. 

 

Regardless the type of installation, the base station must be installed away from 
obstacles possibly altering the reception, and so that it must not receive more 
than -20dBm signals from 0 to 821MHz and from 925MHz to 2.5GHz.  

 

General recommendation for outdoor installation would be to not place the 
Access Station Micro in direct line of sight of broadcasting equipment or cellular 
station. 
 
For indoor installation, place the station in a different room as other RF 
equipment, when possible install the station on a different floor. 
 
Use of cell phones in direct vicinity of the Access Station Micro will not affect 
neither its range, nor its quality of service. 
 
In case of third party equipment in close proximity, with line of sight visibility and 
horizontal alignment, following physical separation is recommended: 
 

System type 

Minimum physical separation 

indoor 

outdoor 

100KW Broadcast (FM or digital TV DBV-T)

 

1000m

 

3000m 

Cellular macrocell (N x 2kW panel)

 

100m

 

300m 

Cellular pico station 

2m 

N/A 

868-925 MHz SRD / ISM equipment

 

100m

 

1000m 

Wi-Fi 

1m 

1m 

www.ime.de

19-10-20

Содержание SBMS-T4

Страница 1: ...system documentation is official and applicable This document is confidential and is the property of Sigfox It shall not be copied and or disclosed to third parties in any form without Sigfox written...

Страница 2: ...e length 10 5 2 3 Power consumption 11 5 3 Connectivity 12 5 3 1 Ethernet connectivity 12 5 3 2 Cellular connectivity 13 5 4 Commissioning 13 5 5 LED status 14 6 Annexes 15 6 1 Labels 15 6 1 1 Product...

Страница 3: ...x Access Station Micro series are ultra wide range high linearity transceivers units and feature first class performance radio and innovative software defined radio processing for use in Ultra Narrow...

Страница 4: ...Accessories available separately Sealing cover USB cellular dongle containing a specific firmware compatible with Sigfox Access Station Cellular Type Model Firmware Zone 3G MS2131i 8 SIG 21 751 11 00...

Страница 5: ...with third party SRD ISM systems operating on the same band is forbidden Regardless the type of installation the base station must be installed away from obstacles possibly altering the reception and...

Страница 6: ...side 4 2 Access Station Mounting The following table describes the different mounting options offered with the kit included in the package Wall Mounting Pole Mounting Kit 2 screws 4 5x30mm anchors for...

Страница 7: ...4 Site selection Radio performance will depend on site configuration Whatever the type of installation the station should be clear of massive obstacles or metallic surface within 1m since possibly al...

Страница 8: ...the last floor in case of cellular BS on the roof and away from windows to reduce RF interferers from cellular broadcasters Note When installed vertically on a wall the connector must be facing downw...

Страница 9: ...9 4 4 2 Outdoor For outdoor deployment it is recommended to place the Access Station Micro above facing and in the periphery of the connected devices for best result www ime de 19 10 20...

Страница 10: ...age range 11V DC to 26V DC from the supplied PoE injector Station minimum input voltage 10V DC Max input current 1A Injector DC connector 5 5mm x 2 1mm Note The station cannot be powered with IEEE 802...

Страница 11: ...atures Typical 2 3W RX mode or 4W TX mode with Ethernet connection Average power consumption with warm up mode 4 8W Peak consumption 7 5W with heating mode Heating mode 6 3W temperature 0 C Use of cel...

Страница 12: ...ivate LAN or direct Backhaul connection the host network should receive proper configuration to allow the IP communication between Sigfox Access station and Sigfox Cloud Performance requirement Minimu...

Страница 13: ...g Commissioning of the station is done online by the Sigfox Operator via the Backend interface Pre commissioning modification of network settings and registering site location can be done with the Acc...

Страница 14: ...upport Orange Flashing Establishing connectivity IP not allocated If the light remains flashing orange after 1 minute check network connection Check DHCP server and IT configuration Orange Establishin...

Страница 15: ...as been validated for a country the product will be compliant and the label will be updated if necessary Check the lasted version of the Safety notice Product certifications available online for up to...

Страница 16: ...latory groups for SMBS T4 REGULATORY GROUP RADIO ACCESS MODE OPERATING BAND MAX OUTPUT RADIATED POWER EIRP COUNTRY A FH 915 928MHz 23dBm AUSTRALIA B FH 902 907 5 915 928MHz 23dBm BRAZIL C FH 915 928MH...

Страница 17: ...NVIRONMENTAL Product weight 450g 1 lb Operating temperatures 20 C to 55 C Storage temperatures 30 C to 85 C Robustness MTBF 92 000 hours Casing material Plastic ASA PC Dimensions in mm Sealing cover w...

Отзывы: