background image

 

 

 

 

International Manufacturing & Design LLC 

 

 

 

 

Owner’s Manual 

 

 

 

 

 

 

PTO10/2S  -   PTO15/2S 

 

(Photo is not representative for all model types) 

 

 

 

 

 

 

Содержание PTO10/2S

Страница 1: ...International Manufacturing Design LLC Owner s Manual PTO10 2S PTO15 2S Photo is not representative for all model types ...

Страница 2: ...ARNING symbol That information is intended to help you avoid damage to your unit other property the environment or your safety We suggest you read the warranty policy to fully understand its coverage and your responsibilities of ownership When your PTO generator needs scheduled maintenance keep in mind that your servicing dealer is specially trained in servicing the unit Your servicing dealer is d...

Страница 3: ...uipment powered by the PTO generator 4 Operation Starting the PTO generator How to power tools or electrical items Shutting off the PTO generator PTO alignment 5 Servicing your PTO generator The importance of maintenance Warranty 6 Helpful Suggestions Storage Transportation 7 Technical Information IMD LLC Customer Service 2607 Woodruff Rd Suite E 310 Simpsonville SC 29681 USA Tel 864 295 6773 ...

Страница 4: ...HURT IF YOU DON T FOLLOW INSTRUCTIONS You will find safety information in a variety of forms including Safety Messages preceded by a safety alert symbol and one signal word WARNING or DANGER Contents a Important Safety Information b Electric Shock Prevention c Connection d Fire Hazard e Deadly Exhaust Gas f Noise Hazard g Operation h Explanation of The Different Safety Labels ...

Страница 5: ...efore the PTO generator can be connected to a building s electrical system a licensed electrician must install an isolation transfer switch in the building s main fuse box The switch is the connection point for PTO generator power and allows selection of PTO generator or main line power to the building This will prevent the PTO generator from charging the main power line backfeeding when the main ...

Страница 6: ...zard of possible explosion and or fire Keep a fire extinguisher nearby and know its proper use Fire extinguisher rated ABC by NFPA is appropriate e Deadly exhaust gas Exhaust fumes from any engine contain carbon monoxide an invisible odorless and deadly gas that must be mixed with fresh air Operate your PTO generator only in well ventilated areas Never operate indoors ...

Страница 7: ...rive shaft when it is in operation Keep all safety guards and shields in place and securely tightened do not operate without shaft safety cover Never operate a drive shaft that has been damaged or had safety shield removed Never step over a drive shaft while it is running Never wear a necktie loose articles of clothing or anything else that can be caught in moving parts Never try to stop a turning...

Страница 8: ...s possibly lethal electric shock Do not open the flap and touch the modular connector receptacle when the PTO generator PTO 15 2S only is in operation or switched on Use extreme caution Never handle any kind of electrical device while standing on water while barefooted or while hands or feet are wet Dangerous electric shock that can cause severe personal injuries or death will result ...

Страница 9: ...e power take off PTO shaft represents extreme danger Fatal injuries may result if protective devices are not used properly and at all times Never stand near the PTO shaft if it is in operation Always make sure that all safety devices are correctly in place Replace any damaged safety devices immediately and do not operate the equipment until such replacement is made The PTO shaft safety guard must ...

Страница 10: ...Page 10 2 Controls Panel Always verify that the PTO generator is properly grounded before use Voltmeter 50 Amp receptacle 20 Amp duplex receptacle Main circuit breaker ...

Страница 11: ...d in before starting the PTO generator Make sure the tool is turned off before plugging it in PTO alignment Position the PTO generator in such a manner that the power take off shaft is as near to direct line in all directions as possible This will increase the life of the power take off shaft reduce ware on bearings of both the power take off and the alternator and reduce vibration The maximum ang...

Страница 12: ...tor does not exceed the PTO generator s ampere and voltage capacity Before plugging in the electrical apparatus make sure that the circuit breakers and protectors are in the off position and that the electrical unit or tool will not start during connection with your PTO generator or during controlling the circuit breakers and protectors Plug your apparatus in the fitting NEMA Socket of the PTO gen...

Страница 13: ...SOW90 140 Kendal Three Star BSW 140 Amoco 85W140 or equivalent The PTO generator bearings are factory lubricated and sealed and require no further lubrication The splinted PTO generator input shaft should be cleaned and lubricated with a thin film of grease before and after each use of the PTO generator The drive shaft tumbling bar requires greasing See the following picture for lubrication schedu...

Страница 14: ...age caused by any chemicals other than the ones authorized to be used in connection with the operation of the product unauthorized repair or modification use of non proprietary or aftermarket spare parts or failure to follow the manufacturer s instructions with respect to the proper handling operations installation service and maintenance of the product 3 Normal wear and tear are not covered by th...

Страница 15: ...RODUCT BEYOND THE 6 MONTHS PERIOD HOWEVER SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO IN SUCH STATES THE ABOVE LIMITATION MAY NOT APPLY TO YOU IF THIS PRODUCT IS DEFECTIVE YOUR ONLY REMEDY IS REPAIR OR REPLACEMENT AS DESCRIBED ABOVE UNDER NO CIRCUMSTANCES WILL THE MANUFACTURER ITS DISTRIBUTORS DEALERS OR AGENTS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INC...

Страница 16: ...te length and fitted with a safety circuit breaker Before starting rotation of the propeller shaft place the PTO generator on the ground Storage Proper Storage preparation is essential for keeping your PTO generator trouble free and looking good The following information will keep rust and other corrosion from impairing your machine s function and appearance and will make the unit easier to start ...

Страница 17: ... Off Shaft Power 20 HP 29 HP Shaft Speed Standard 540 rpm Standard 540 rpm Receptacles b h b h I Dimensions LxWxH 29x35x38 35x35x38 Dry Weight 209 lbs 284 lbs Receptacles I 125V 250V 175A b Duplex 125V 5 20 h 50A 125V 250V L14 50 Options Simultaneous 120V 240V Use X X Full Power 240V Outlet X X Voltmeter X X Magnetic Circuit Breaker X X PTO 3 Point Hitch for Traktor O PTO Base for Trailer or Stand...

Страница 18: ...Page 18 Wiring Diagrams Wiring Diagram PTO10 2S ...

Страница 19: ...Page 19 Wiring Diagram PTO15 2S ...

Отзывы: