INSTRUMENTATION WITH QUALITY ENGINEERING
INSTRUMENTATION WITH QUALITY ENGINEERING
INSTRUMENTS, INC.
INSTRUMENTS, INC.
®
FREZE-PMP->ON
LOWTEMP-PMP>OF
COL=174.1 STO= 1 10 . 4
PKH =18 0.4 PKL= 6 0 . 1
DI F=0 8 . 0 H IL= 17 5 . 3
PMP= O N UPL=ON
COL=174.1 STO= 1 10 . 4
PKH =18 0.4 PKL= 6 0 . 1
DI F=0 8 . 0 H IL= 17 5 . 3
PMP= O N UPL=ON
SYSTEM OVERRIDE MESSAGES
on the LOWER LCD LINE as follows:
FLASH
PG 4
PG 3
PG 2
PG 1
SUN CONTROL
DIFFERENTIAL TEMPERATURE CONTROLLER
SUN CONTROL
EAGLE 2
IMC’S LCD MASTER DIGITAL DISPLAY PANEL
FOR REMOTE INDICATION
P# SOLR-2ELC-10
LCD DISPLAY
The LCD display has 2 lines of 20 characters each. The first line permanently displays the COLLECTOR and the
STORAGE temperatures. The second line can be paged by pressing the button located just below the LCD
display. The following 4 pages display all system information including OVERRIDE messages.
- Two industrial 400°F (204°C) rated 10 K thermistors
with +/- 1°F accuracy are included.
- Two auxiliary thermistor inputs
for optional sensors that can be located up to 1000’ away.
- Selectable overrides
for
low temperature shut down
or
freeze protection
modes for
safe operation.
MAIN FEATURES
- Microprocessor
accuracy and
dependability with ambient
operation from -10 to 120 F
- Large easy-to-read 40 character
(20x2) backlit LCD
display showing every parameter measured and
Controlled by the microprocessor.
- PC DATA PORT
with built-in transmitter allows optional
adapter and up to 500 ft. cable to interface with computers
for ease in startup and remote diagnostics. Or, for adding
an
Optional large 80 character
(4x20) backlit LCD display.
Remote-mount up to 150 ft. distances with a CAT-5 cable.
- Long-term diagnostics
and data logging is possible using
communications software that is included in Windows’ OS.
- Fault LED indicators
for quick servicing and diagnostics
- Features for fast installation
and wiring
- Electrostatic
discharge protected
- One HP or 20 AMP
high reliability relay
- Polyester coated 16 gage
rugged steel enclosure
- Model available
with receptacle & power cord or with 1/2”
conduit holes for higher current permanent wiring
°
SERVICE AND INSTALLATION INSTRUCTIONS
Tel
:
715- 253-2801 Ver.11-01-2008
Fax
:
715- 253-2811
Web
:
www.solar.imcinstruments.com
468 Liberty Drive
Wittenberg, WI 54499
U.S.A.
Содержание EAGLE 2 SOLR-2ELC-10