iberLinX TX/FX

iberLinX TX/FX

I n s t a l l a t i o n   G u i d e

About FiberLinX TX/FX

FiberLinX TX/FX™

from IMC Networks is a

SNMP-manageable networking device for provi-
sioning point-to-point fiber optic connections
between two locations. The primary advantage
of FiberLinX TX/FX is End-to-End management,
which allows the device administrator to moni-
tor the fiber run between the head-end and
remote site as a single entity, not as two sepa-
rate locations.  FiberLinX allows the device
administrator to manage the remote unit without having access to the
remote site, allowing the administrator to remain isolated and completely
transparent to the customer network and data traffic.

FiberLinX TX/FX Module

Installation Instructions

Installing a FiberLinX TX/FX Module involves the following steps: 1) con-

figuring the FiberLinX TX/FX Module via its eight-position DIP switches for
SNMP-Management and mode configuraiton, 2) designation of the man-
agement traffic port, 3) configuration of host/remote or standalone opera-
tion and auto-negotiation; along with the installation of the FiberLinX
TX/FX 
module into a PowerChassis/101 or /113 (not for use with
PowerChassis/1/2 or /12).

D I P   S

W I T C H

S

E T T I N G S

Before installing FiberLinX TX/FX into a PowerChassis, you must config-

ure the eight-position DIP switch, located at positions S1 and S3 (shown
on the following page), for configuring the module.

Q U I C K   S T A R T

Introduction

1

DIP Switch Settings

2

FiberAlert

3

Assigning IP Information

4

Using iView

8

If Not Using iView

9

Application Examples

10

LED Indicators

13

Tech Support

14

DIP Switch Location on FiberLinX TX/FX (default settings shown)

The following table shows the function for each of the eight DIP switch-

es on FiberLinX TX/FX.  Refer to the following pages for specific configura-
tion information for each function.

C

O N F I G U R I N G

F

I B E R

L

I N

X   T X / F X  

A S A

H

O S T

,  

R

E M O T E O R

S

TA N D A L O N E

U

N I T

When two FiberLinX TX/FX units are paired with one another, each

FiberLinX TX/FX unit can be configured to be either a 

Host

unit or a

Remote

unit.

As a HostFiberLinX TX/FX requests management information from any

attached remote unit and displays that information, along with its own,
upon SNMP query.  As a RemoteFiberLinX TX/FX will not respond to
requests for management information from an attached unit.  In single
installation, the sole FiberLinX TX/FX should be configured as standalone 
unit (factory default).  The table on the following page shows the possible
DIP switch settings.  Please see page 10 of this guide for possible installa-
tions and their related HostRemote and standalone DIP switch settings.

ON

8

7

6

5

4

3

2

1

Remote Configuration

Host Configuration

SNMP Management on Ext. Mgmt P

ort

SNMP Management on FX Data P

ort

SNMP Management on TX Data P

ort

2

S

WITCH

/P

OSITION

F

UNCTION

D

EFAULT

Switch S1

1 - 6

Factory Configured — DO NOT CHANGE

Varies

7

Remote Configuration

OFF

8

Host Configuration

OFF

Switch S3

1

SNMP Management Traffic  for the TX Mgmt. Port

OFF

2

SNMP Management Traffic  for the TX Data Port

ON

3

SNMP Management Traffic  for the FX Data Port

OFF

4 - 8

Factory Configured — DO NOT CHANGE

Varies

Содержание FiberLInX TX/FX

Страница 1: ...Assigning IP Information 4 Using iView 8 If Not Using iView 9 Application Examples 10 LED Indicators 13 Tech Support 14 DIP Switch Location on FiberLinX TX FX default settings shown The following tab...

Страница 2: ...ber loop FiberAlert Cable Break XMT RCV LED Remote Site Local Site LED OFF Broken Link LED XMT RCV a fiber link FiberAlert disables its fiber transmitter thus mirroring the link status of the opposite...

Страница 3: ...serial port on the computer terminal should be set for 38 4K baud 8 data bits 1 stop bit no parity and no flow control 5 D B 9 P I N C O N N E C T I O N Pin 2 3 5 7 8 1 4 6 9 Function Transmit OUT Re...

Страница 4: ...main configuration screen You will be asked to enter a pass word NOTE Passwords are case sensitive Enter your password spaces are NOT allowed and press Enter You will then be asked for your pass word...

Страница 5: ...opriately Packets not addressed for management ports are sent through to the network Similarly management packets are forwarded internally to the manage ment engine and are not forwarded More informat...

Страница 6: ...R E C T F I B E R S W I T C H C O N N E C T I O N F R O M C E N T R A L T O R E M O T E S I T E To achieve remote management and monitoring capabilities directly con nect a FiberLinX TX FX to a fiber...

Страница 7: ...condensing Electrical Module 5V 5 2 0 Amp Heat Generation 50 BTU hr F I B E R O P T I C C L E A N I N G G U I D E L I N E S Fiber Optic transmitters and receivers are extremely susceptible to contami...

Страница 8: ...ER WARRANTIES WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THIS IMC NETWORKS PRODUCT INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSO CIATED OR INCLUDED IMC NETWORKS SHALL DISREGARD AND NOT BE BOUND BY AN...

Отзывы: