Fan Module Replacement
The front fan modules are individually mounted and connected. An additional fan is located
next to the right power supply.
Follow these steps to remove and replace a fan:
1
Remove the X50 cover, as described on page 106, ensuring
both
power supplies are
disconnected
2
Snip and remove the plastic ties wraps holding the fan wires.
Figure C-10.
Fan Wires
3
Carefully unplug the power connector for the failed fan.
4
Remove the two mounting screws for the failed fan, and then remove the fan.
5
Attach the new fan using the screws provided.
6
Attach the connector to the circuit board.
7
Carefully bundle and re-wrap the wires through the metal holders, ensuring that no wires
contact the blades of the fans.
8
Replace the cover as described earlier, and then re-attach the two power cords.
Snip and remove these
tie wraps
Front fan
connectors
Power supply
fan connector