![Imagine Platinum VX Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/imagine/platinum-vx/platinum-vx_installation-and-operation-manual_2045406023.webp)
Platinum™ VX
Installation and Operation Manual
Platinum VX Installation
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 1.2 | Page 23
Setting IP and Subnet Mask Addresses
To allow devices to communicate on a network, you need to set all Platinum VX devices to the same
subnet (network location). When shipped, Platinum VX units are configured with the same default IP
(device identifier) and subnet addresses. These addresses need to be changed so that each unit is
uniquely identified and the network location of all units is accurately reflected.
The default (factory-configured) ENET 1 IP address for every Platinum VX unit is
192.168.100.250.
For a
class C network, you must change the first three items in the octet to identify the location (address) of
the unit on your network, and also change the last item in the octet to uniquely identify the device from
other Platinum VX units. The default subnet mask address for every Platinum VX is 255.255.255.0.
See System and Network Requirements (on page 80).