![Imagine Platinum IP3 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/imagine/platinum-ip3/platinum-ip3_installation-and-operation-manual_2045405048.webp)
Platinum™ IP3
Installation and Operation Manual
Resource Module (PX-RES)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 48
For user configurable references, 4 discrete syncs or 2 syncs with redundant inputs are supported
Sync triggering supported based on reference detection
If no sync signals present, switches occur asynchronously after a reasonable time-out period (<0.1
seconds from reception of command)
For Sync references that are present but then removed or lost, the router maintains relative vertical
interval switching until a reference is detected
Also See Switch Triggering (on page 54).
Alarm Port
Reserved for future use.
LTC Bi-Directional Port
Reserved for future use.
LEDs
The following LEDs are present on the module:
Power
Active Card
ENET 1 LED
ENET 2 LED
2 Alarm LEDs
Table 12:
LEDs on the PX-RES Resource Module
LED
DESCRIPTION
POWER
Power Supply Indicator
Green
Indicates that 24V is enabled on this board
ENET1
Flashing Green
Indicates there is an active connection on Ethernet Port #1 *
ENET2
Flashing Green
Indicates there is an active connection on Ethernet Port #2 *
ALARM1
ALARM2
Off
No alarm
Red
ALARM2 LED turns red if the synchronization process fails
Amber
ALARM1 is lit amber when the PX-RES is in fail-safe mode
Flashing Red
Flashing Amber
ALARM2 LED flashes amber when synchronization between the active and standby
PX-RES is in progress.
ALARM1 LED flashes amber when a user sets the frame identifying LLDC parameter
ACTRES
Green
On for the active PX-RES module