HUC6800
+
Installation and Operation Manual
33
Chapter 3: Operation
Changing Parameter Settings
Follow these steps to change the HUC6800
+
and HUC6800
+
C
parameter settings:
1. Rotate the mode select rotary switch (hex switch) to “0.”
2. Once the hex switch is set to “0,” toggle the navigation switch up or
down to select a bank.
View the three control LEDs next to the navigation toggle switch to
see which bank is currently selected.
3. Rotate the hex switch to the parameter number (1 to 9) or letter
(A to F) of the option you want to set.
4. Toggle the navigation switch to select and set the value of the
chosen parameter.
5. Rotate the hex switch to another parameter number/letter in the
current bank, and then repeat step 4.
or
Rotate the hex switch to “0” again to select a different bank, and
then repeat steps 3 and 4.
See
to view the various banks, hex switch
positions, and corresponding parameter options and values.
Table 3-3.
Bank Select LEDs
Bank
Number
Bank 0 LED
(first top LED)
Bank 1 LED
(second top LED)
Bank 2 LED
(third top LED)
0
Off
Off
Off
1
On
Off
Off
2
Off
On
Off
3
On
On
Off
4
Off
Off
On
5
On
Off
On
Note
The manufacturer recommends
that you use the available 6800
+
software control options (serial/
local or Ethernet/remote) to aid
in viewing, setting, and
confirming parameter values.
Содержание Selenio 6800 HUC6800
Страница 3: ...Edition A July 2006 HUC6800 and HUC6800 C Broadcast Upconverters Installation and Operation Manual...
Страница 4: ......
Страница 8: ...vi HUC6800 Installation and Operation Manual Contents...
Страница 22: ...8 HUC6800 Installation and Operation Manual Chapter 1 Introduction...
Страница 36: ...22 HUC6800 Installation and Operation Manual Chapter 2 Installation...
Страница 70: ...56 HUC6800 Installation and Operation Manual Chapter 4 Specifications...
Страница 78: ...64 HUC6800 Installation and Operation Manual Appendix A Communication and Control Troubleshooting Tips...
Страница 82: ...68 HUC6800 Installation and Operation Manual Index...
Страница 83: ......