CMN-91
Installation and Operation Manual
Setup Menu Functions
© 2016 Imagine Communications Corp. Proprietary and Confidential.
Revision D | Page 112
Contrast: This selection option is used to adjust the overall difference between the lightest and
darkest colors of the vector. The range of contrast is 0% to 100%. The default selection is 55%.
Persistence: This selection option is used to determine how long a data point (pixel) in the vector
remains on the display. The range of persistence is 0% to Infinite. The default selection is 0%.
Attack: This selection option is used to determine the initial intensity that the data point (pixel)
appears in the display. The range of Attack is 1% to Maximum. The default selection is 10%.
Gamut Setup Menu
The Gamut Setup menu is used to change a gamut’s color plots, Data Error Persistence, Intensity,
Contrast, and Persistence.
Menu Selections
Gamut Setup Menu
Selection Option
Selection Option
Single color
RGB*
Composite
Data Error Persistence
0% to Infinite (0%*)
Intensity
0% to 100% (86%*)
Contrast
0% to 100% (55%*)
Persistence
0% to Infinite (0%*)
Menu Selection Descriptions
Single Color, RGB, Composite (Color Plot): These selection options are used to set the color for
plotting RGB pixels. The pixels can be one single color or RGB (red, green, or blue). Multiple colors
help to indicate which color of the RGB signal moves beyond the inner and outer parameters of the
gamut graticule. The default selection is RGB.
Data Error Persistence: This selection option is used to determine how long a point of data beyond
the inner and outer parameters of the gamut graticule. The range of persistence is 0% to Infinite.
The default selection is 0%.
Intensity: This selection option is used to raise or lower the brightness of the displayed gamut. The
range of intensity is 0% to 100%. The default selection is 86%.
Contrast: This selection option is used to adjust the overall difference between the lightest and
darkest colors of the gamut. The range of contrast is 0% to 100%. The default selection is 55%.
Persistence: This selection option is used to determine how long a data point (pixel) in the Gamut
remains on the display. The range of Persistence is 0% to Infinite. The default selection is 0%.