Menu Selection Descriptions
Display Format: This selection option allows a choice of display formats: YCbCr (default), RGB,
Composite, YCbCr + Alpha, RGB + Alpha, and YRGB. lists the relationships between the input and
display formats.
Input and Display Format Relationship
Input
Format
YCbCr
RGB
Composite
YCbCr + Alpha
(10 bit only)
RGB + Alpha
(10 bit only)
YRGB
3Gb/s
Yes
Yes
Yes
Yes
Yes
Yes
HD
Yes
Yes
Yes
Yes
Yes
Yes
SD
Yes
Yes
Yes
No
No
Yes
Component Filter: Component filters are used when the waveform display format is set to YCbCr or
RGB. Filter selection options are Flat, Low Pass, and Bowtie.
Flat: No filtering (default)
Low Pass: Selects the Low Pass filter
Bowtie: Checks the timing relationships between the digital components (a bowtie test signal is
required)
Composite Filter: Composite filters are used when the waveform display format is set to Composite.
Filter selections are Flat, Low pass, Chroma, and Flat and Low Pass.
Flat: No filtering (default)
Low Pass: Selects the Low Pass filter
Chroma: Selects the Chroma filter
Flat and Low Pass: Selects Flat and Low Pass filtering
Component Overlay: When Component Overlay is selected for a single input, the components of
the input signal are displayed over each other (that is, R over G over B in an RGB signal).
Blanking: The blanking selections are Blank All, EAV/SAV, and Show All.
Blank All displays only the active video of the input signal (default).
Show EAV/SAV displays the active video and the EAV/SAV headers of the input signal.
Show All displays the ancillary data, EAV/SAV, and active video.
Error Highlighting: Error highlighting changes the color of the portion of the waveform that exceeds
the alarm settings. The default setting is OFF. The highlighting is dependent upon the format and
gamut settings selected. The following are rules to consider:
Composite format with Flat filter follows the alarm settings for Gamut Peak upper and lower. It
follows the threshold settings for the alarm, even when it is not enabled.
Composite format with Low Pass filter follows the Luma Upper and Lower thresholds.
Component format with RGB filter will follow the RGB gamut.
No highlighting in YCbCr.
Graticule: This selection option is used to select the unit of measurement in percent or volts for the
Digital Waveform Graticule, and in volts or units for the PAL Waveform Scale.
NTSC Pedestal: This selection option adds setup to the Composite display (default).
Intensity: This selection option is used to raise or lower the brightness of the displayed waveform.