Imac Pulsimatic Скачать руководство пользователя страница 1

Bulletin: 60620.installation 

 

 

 
Pulsimatic Instructions & Specifications:  

 
The Pulsimatic Transmitter’s aluminum casting has been drilled in a 8-hole universal mounting pattern 
to accommodate mounting with commonly used commercial and industrial gas meters (these meters 
include turbine, rotary and diaphragm gas meters) and correcting instruments.  
 

*Before installing the Pulsimatic on a gas meter make sure to run shielded cable through the 
connection on the side of the Pulsimatic to the terminal strip underneath the Pulsimatic * 

 

Mounting Instructions:  
 

1.) Remove the existing meter index or instrument from meter.   
2.) Place the Pulsimatic and gasket over the meter mounting holes,  
the ‘Pulsimatic front’ sticker must be aimed in the same direction 
as the front of the meter.  
3.) Reinstall the original index or instrument on top of the  
Pulsimatic 

 
 
Model Characteristics:   

1/2, 1, 2, 5, 10, 20, 50 Pulse Per 

Revolution 

100 Pulse Per Revolution 

500 / 1000 Pulse Per Revolution 

Dry Contact Form C Reed Switch 

Switch Electrical Characteristics: 

Maximum Switching Voltage: 175 dc 

Minimum Breakdown Voltage: 200 dc 

Maximum Switching Current: 250 ma 

Initial Contact Resistance 200 ohms 

Max. Switching Time: 0.7 milliseconds 

Operating Temperature -40º to 105º C 

Anticipated Minimum Life: 50,000,000 

cycles @ 5vdc, 10 ma 

Optical Encoder 

Power Supply =  6-24 VDC (output 

square wave with same amplitude as 

power supply) 

 

Wiring Diagram: 

 
 
 

High Output Encoder 

Power Supply = 6-24 VDC Signal 

processed and amplified (output square 

wave with the same amplitude as power 

supply or additionally a selectable 5V 

regulated output). 

 

 
Special Meter Considerations: 

American Meter 

 

Sensus / Invensys / 

Rockwell / Equimeter 

Actaris / Sprague / 

Schlumberger 

--Mounting studs are unique 18-18 thread 
--AL800, AL1000, AL1400 and B-Series Meters 
require extended shaft and Base Plate.  Extended 
shaft must be specified when ordering and base 
plate must be ordered separately. 
   Base plate will be 
   installed between meter 
   and Pulsimatic. 
--When installing on GT, GTX, or GTS Turbine 
Meters a seal plate is recommended to eliminate 
overhang 

--Only 2 standard 
mounting studs are 
required for installation 
 

--DMK-217 Mounting 
Kit required for 675a, 
800a and 1000a Meters 
 

 
___________________________________________________________________________ 

IMAC Systems, Inc.           

      

 Tel 215 946-2200 • 800 955-4GAS Fax 215 943-2984                 

            

90 Main Street • Tullytown • Pa • 19007                                   www.imacsystems.com • [email protected] 