background image

Model ID: LOGICGZS

Quick Reference Guide

English

EN

Español

ES

Français

FR

Deutsch

DE  

Nederlands

NL

Содержание LOGICGZS

Страница 1: ...Model ID LOGICGZS Quick Reference Guide English EN Espa ol ES Fran ais FR Deutsch DE Nederlands NL...

Страница 2: ...he light source contained in this luminaire shall only be replaced by the manufacturer its service agent or a similarly qualified person The luminaire is intended for professional use only DO NOT open...

Страница 3: ...olid copper wire shielded CAT6 A terminated with RJ45 connectors Stranded conductors not supported Total Max Cable Length LOGIC DRIVE 2X to first fixture 100 m 328 ft Total Max Cable Length LOGIC DRIV...

Страница 4: ...ace and hardware are capable of supporting the weight of the product To mount the LOGIC GZ S in any orientation up light down light or side light 1 Rotate the integrated mounting brackets so they are...

Страница 5: ...ntrol color temperature strobe auto programs and speed dimmer speed Network Net Switch 2 X X X Selects the first value of the IP address 10 X X X Universe 000 255 001 256 Selects universe Art Net sACN...

Страница 6: ...0x0051 Product Information DEVICE_INFO 0x0060 1 RDM Protocol Version V1 0 2 Device_Mode_ID 0x1732 3 Product Category Defines PRODUCT_CATEGORY_FIXTURE_FIXED 4 Software Version ID 5 DMX512 Footprint 6 D...

Страница 7: ...fast 026 189 No function 000 255 Random strobe slow to fast 8 Auto programs 000 040 No function 041 050 Automatic program 1 051 060 Automatic program 2 061 070 Automatic program 3 071 080 Automatic pr...

Страница 8: ...ture 000 010 No function 011 020 1800K 021 030 2200K 031 040 2700K 041 050 3000K 051 060 3200K 061 070 4000K 071 080 4500K 081 090 5000K 091 100 5600K 101 110 6000K 111 120 6500K 121 130 7000K 131 140...

Страница 9: ...00 hours Optics Beam Angle Field Angle Cutoff Angle Illuminance 5 m Open optics 121 4 x 120 5 142 3 x 164 1 150 2 10 lux 5 m Medium optics installed 29 x 41 3 59 7 x 82 2 100 1 43 lux 5 m Very Wide fi...

Страница 10: ...luminaria est destinada exclusivamente a un uso profesional NO abra este producto No contiene piezas reparables por el usuario NO mire a la fuente de luz cuando el producto est encendido Cuidado cuan...

Страница 11: ...0 5733 mm apantallado CAT6 A terminado con conectores RJ45 No compatible con conductores trenzados Longitud del cable m xima total LOGIC DRIVE 2X al primer aparato 100 m 328 Longitud del cable m xima...

Страница 12: ...cie y el material de montaje sean capaces de soportar el peso del producto Para montar el LOGIC GZ S en cualquier orientaci n luz arriba luz abajo o luz lateral 1 Gire los soportes de montaje integrad...

Страница 13: ...eratura de color estroboscopio programas autom ticos y velocidad velocidad de atenuador Network Net Switch 2 X X X Selecciona el primer valor de la direcci n IP 10 X X X Universe 000 255 001 256 Selec...

Страница 14: ..._DESCRIPTION 0x0051 Product Information DEVICE_INFO 0x0060 1 RDM Protocol Version V1 0 2 Device_Mode_ID 0x1732 3 Product Category Defines PRODUCT_CATEGORY_FIXTURE_FIXED 4 Software Version ID 5 DMX512...

Страница 15: ...9 Estroboscopio 0 25 Hz 011 109 Sin funci n 000 179 Estroboscopio rel mpago lento a r pido 026 189 Sin funci n 000 255 Estroboscopio aleatorio lento a r pido 8 Programas autom ticos 000 040 Sin funci...

Страница 16: ...guraci n 1 Rojo 000 255 0 100 2 Verde 000 255 0 100 3 Azul 000 255 0 100 Canal Funci n Valor Porcentaje Configuraci n 1 Atenuador 000 255 0 100 2 Temperatura de color 000 010 Sin funci n 011 020 1800K...

Страница 17: ...Corriente Vida til LED RGBwW 9 2 5 W 870 mA 50 000 horas pticos ngulo de haz ngulo de campo ngulo de corte Iluminancia a 5 m ptica abierta 121 4 x 120 5 142 3 x 164 1 150 2 10 lux 5 m ptica media ins...

Страница 18: ...re de service ou une personne suffisamment qualifi e Ce luminaire est uniquement r serv un usage professionnel N ouvrez PAS cet appareil Il ne contient aucun composant susceptible d tre r par par l ut...

Страница 19: ...t ou sACN depuis le LOGIC DRIVE 2X via une connexion CAT6 Connexion et c blage Le LOGIC GZ S dispose d un port IN entr e et un port OUT sortie qui n cessitent des connexions Ethernet CAT6 A Exigences...

Страница 20: ...lisser le filtre entre le bo tier ext rieur et les lentilles LED Cette op ration doit tre effectu e sans outils Les tol rances de longueur de c ble varient d un fabricant l autre V rifiez toujours que...

Страница 21: ...appareil Pour monter le LOGIC GZ S L dans n importe quelle orientation clairage vers le haut clairage vers le bas ou clairage lat ral 1 Faites pivoter les supports de montage int gr s afin qu ils ne...

Страница 22: ...couleur stroboscope programmes automatiques et vitesse vitesse du gradateur Network Net Switch 2 X X X S lectionne la premi re valeur de l adresse IP 10 X X X Universe 000 255 001 256 S lectionne l un...

Страница 23: ...TER_DESCRIPTION 0x0051 Product Information DEVICE_INFO 0x0060 1 RDM Protocol Version V1 0 2 Device_Mode_ID 0x1732 3 Product Category Defines PRODUCT_CATEGORY_FIXTURE_FIXED 4 Software Version ID 5 DMX5...

Страница 24: ...atoire lent rapide 8 Programmes automatiques 000 040 Pas de fonction 041 050 Programme automatique 1 051 060 Programme automatique 2 061 070 Programme automatique 3 071 080 Programme automatique 4 081...

Страница 25: ...e fonction 011 020 1800K 021 030 2200K 031 040 2700K 041 050 3000K 051 060 3200K 061 070 4000K 071 080 4500K 081 090 5000K 091 100 5600K 101 110 6000K 111 120 6500K 121 130 7000K 131 140 8000K 141 150...

Страница 26: ...ant Dur e de vie LED RGBwW 9 2 5 W 870 mA 50 000 heures Optique Angle de faisceau Angle de champ Angle de coupure clairement 5 m Optique ouverte 121 4 x 120 5 142 3 x 164 1 150 2 10 lux 5 m Optique mo...

Страница 27: ...r den professionellen Einsatz bestimmt Dieses Ger t NICHT ffnen Die eingebauten Komponenten sind f r den Kunden wartungsfrei NIEMALS in die Lichtquelle schauen w hrend das Ger t eingeschaltet ist VOR...

Страница 28: ...DMX RDM Art Net oder sACN vom LOGIC DRIVE 2X ber eine CAT6 Verbindung Anschlie en und Verkabelung Der LOGIC GZ S verf gt ber 1 IN Eingang und 1 OUT Ausgang f r die eine CAT6 A Ethernet Verbindung erf...

Страница 29: ...en Filter zwischen dem u eren Geh use und den LED Linsen ein und herausschieben Dies sollte ohne Werkzeug erfolgen Die Toleranzen f r die Kabell nge variieren je nach Hersteller berpr fen Sie vor der...

Страница 30: ...wicht tragen zu k nnen So montieren Sie den LOGIC GZ S in einer beliebigen Ausrichtung Lichtstrahl nach oben unten oder zur Seite 1 Drehen Sie die integrierten Befestigungsb gel so dass sie vom Produk...

Страница 31: ...Dimmergeschwindigkeit Network Net Switch 2 X X X Damit w hlen Sie den ersten Wert der IP Adresse aus 10 X X X Universe 000 255 001 256 Damit w hlen Sie das Universum aus Art Net sACN Local Info Protoc...

Страница 32: ...RIPTION 0x0051 Product Information DEVICE_INFO 0x0060 1 RDM Protocol Version V1 0 2 Device_Mode_ID 0x1732 3 Product Category Defines PRODUCT_CATEGORY_FIXTURE_FIXED 4 Software Version ID 5 DMX512 Footp...

Страница 33: ...sam nach schnell 8 Automatischen Programme 000 040 Keine Funktion 041 050 Automatische Programm 1 051 060 Automatische Programm 2 061 070 Automatische Programm 3 071 080 Automatische Programm 4 081 09...

Страница 34: ...ur 000 010 Keine Funktion 011 020 1800K 021 030 2200K 031 040 2700K 041 050 3000K 051 060 3200K 061 070 4000K 071 080 4500K 081 090 5000K 091 100 5600K 101 110 6000K 111 120 6500K 121 130 7000K 131 14...

Страница 35: ...er LED RGBwW 9 2 5 W 870 mA 50 000 Stunden Optik Abstrahlwinkel Feldwinkel Abschaltwinkel Beleuchtungsst rke 5 m Offene Optik 121 4 x 120 5 142 3 x 164 1 150 2 10 lux 5 m Mittlere Optik installiert 29...

Страница 36: ...oudsagent of een soortgelijk erkend persoon De armatuur is uitsluitend bedoeld voor professioneel gebruik Open het product NIET Het bevat geen te onderhouden onderdelen KIJK NIET in de lichtbron wanne...

Страница 37: ...T6 A afgesloten met RJ45 connectoren Gevlochten geleiders niet ondersteund Totale maximale kabellengte LOGIC DRIVE 2X naar het eerste apparaat 100 m 328 ft Totale maximale kabellengte LOGIC DRIVE 2X t...

Страница 38: ...ur het gewicht van het product kan dragen Om de LOGIC GZ S in elke richting te monteren opwaarts licht neerwaarts licht of zijlicht 1 Draai de ge ntegreerde montagebeugels zodat ze niet door de behuiz...

Страница 39: ...stroboscoop automatische programma s en snelheid dimmer snelheid Network Net Switch 2 X X X Selecteert de eerste waarde van het IP adres 10 X X X Universe 000 255 001 256 Selecteert de universe Art Ne...

Страница 40: ...TION 0x0051 Product Information DEVICE_INFO 0x0060 1 RDM Protocol Version V1 0 2 Device_Mode_ID 0x1732 3 Product Category Defines PRODUCT_CATEGORY_FIXTURE_FIXED 4 Software Version ID 5 DMX512 Footprin...

Страница 41: ...estroboscoop langzaam tot snel 8 Automatisch programma s 000 040 Geen functie 041 050 Automatische programma 1 051 060 Automatische programma 2 061 070 Automatische programma 3 071 080 Automatische pr...

Страница 42: ...ur 000 010 Geen functie 011 020 1800K 021 030 2200K 031 040 2700K 041 050 3000K 051 060 3200K 061 070 4000K 071 080 4500K 081 090 5000K 091 100 5600K 101 110 6000K 111 120 6500K 121 130 7000K 131 140...

Страница 43: ...0 000 uur Optieken Stralingshoek Field hoek Drempelhoek Verlichtingssterkte 5 m Open optiek 121 4 x 120 5 142 3 x 164 1 150 2 10 lux 5 m Medium optica ge nstalleerd 29 x 41 3 59 7 x 82 2 100 1 43 lux...

Страница 44: ...Brookhill Road Industrial Estate Pinxton Nottingham UK Website www iluminarc com NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Benelux Address Stokstraat 18 Email BNLtech chauvetlighting eu 97...

Отзывы: