REALISTIC  GAS MANUAL APRIL 14414 DB

I l l u s i o n - A u s t r a l i a n   M a d e   G a s   L o g   F i r e s

INSTALLATION OPTION 1

 INTO FABRICATED ENCLOSURE VERTICALLY ONLY

IMPORTANT:

THE FITTING OF ANY
ENCLOSURE PANEL 
OVER THE HEATER, 
AND OR BETWEEN 
THE HEATER AND THE 
CEILING PANEL 
IS NOT PERMITTED.
ANY HORIZONTAL OR 
VERTICAL SUPPORT 
TIMBERS MUST NOT 
EXCEED 100mm IN 
WIDTH AND MUST NOT 
BE CLOSER THAN 70mm 
TO THE TOP OF THE 
HEATER CASE.

PLEASE NOTE:

ALL ILLusion GAS 

LOG FIRES MUST BE 

INSTALLED BY AN 

AUTHORISED PERSON 

IN ACCORDANCE WITH

AS/NZS 5601 

CURRENT EDITION

FIRST LENGTH OF

ACTIVE FLUE PIPE 

IS STAINLESS STEEL.

ALL OTHERS ARE GALVANISED

The maximum recommended

fl ue length is 3.6m

The recommended minimum distance 
from the top of the heater to the 
underside of ay timber framing is 
70mm provided that the gap between 
any active fl ue pipe and any timber 
or combustible material is a minimum 
of 25mm, or the gap between any 
fl ue outer case and any timber or 
combustible material is a minimum of 
10mm.  Standoffs are provided on the 
top of the appliance body to ensure no 
framing timbers can come in contact 
with the appliance body.

NOTE: All fl ue pipes
including active inner
and any outer cases
mustbe installed with
the crimped end of the
pipe facing up.

Plaster or similar
faced wall with 
timber framing

Содержание Realistic 5000L

Страница 1: ...tion as described in this manual and have been certified by SAI GLOBAL WARNING DO NOT MODIFY THIS APPLIANCE All Illusion Gas Log Appliances MUST be installed and serviced by an authorised person Unaut...

Страница 2: ...Log Fireplace has been fully tested and certified to Australian Standards NOTE Realistic GAS LOG FIREPLACES MODELS 5000L 5000 P ARE DESIGNED TO BE INSTALLED IN A SUITABLY CONSTRUCTED WALL OR FIREPLACE...

Страница 3: ...IMPORTANT Allow min 150mm up from floor when fitting standard window fascia and extra if skirting is fitted to the wall IMPORTANT Realistic MODEL HEIGHT Y MIN WIDTH X MIN DEPTH Z MIN 5000P 780m 920mm...

Страница 4: ...valve THE FOLLOWING INDICATES SITUATIONS OF ABNORMAL OPERATION OF THE APPLIANCE WHEN THE APPLIANCE IS OPERATING 1 The flames appear excessively large and or sooting occurs on the logs 2 You can smell...

Страница 5: ...ates a live fuel effect which is designed to operate with luminous flames and may exhibit slight carbon deposition PILOT FLAME IGNITION Depress and turn the control knob to the PILOT position Depress...

Страница 6: ...Y GUARD THE Realistic GAS LOG FIRE IS SUPPLIED WITH A PRIMARY GUARD FOR YOUR PROTECTION THE PRIMARY GUARD MUST BE FITTED WHEN THE UNIT IS OPERATING THE GLASS FRONT OF THE APPLIANCE IS EXTREMELY HOT WH...

Страница 7: ...THE APPLIANCE TOP AND THE CEILING 1 These appliances must be installed in accordance with the regulations municipal building codes and AS NZS 5601 GAS INSTALLATIONS 2 Only an Authorised person shall i...

Страница 8: ...OLLOWS MINIMUM DIAMETER OF ACTIVE FLUE ALL MODELS IS 127MM A 127mm STAINLESS STEEL FLUE PIPE IS USED FOR THE FIRST LENGTH OF ACTIVE FLUE PIPE GALVANISED FLUE PIPE IS USED FOR SUBSEQUENT LENGTHS THE MI...

Страница 9: ...T EDITION FIRST LENGTH OF ACTIVE FLUE PIPE IS STAINLESS STEEL ALL OTHERS ARE GALVANISED The maximum recommended flue length is 3 6m The recommended minimum distance from the top of the heater to the u...

Страница 10: ...s i o n A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION OPTION 2 INTO EXISTING CHIMNEY VERTICALLY PLEASE NOTE ALL ILLusion GAS LOG FIRES MUST BE INSTALLED BY AN AUTHORISED PERSON IN ACC...

Страница 11: ...e side front log overlaps the left hand side front log 6 Fit the right hand side front log No 7 onto the pins in the front of the grate as shown H FITTING THE LOGS WHEN INSTALLING LOGS ENSURE THAT BUR...

Страница 12: ...N THE GAS VALVE PROCEDURE TURN VALVE TO OFF POSITION LOOSEN INLET PRESSURE POINT 5 ATTACH MANOMETER TO INLET PRESSURE POINT 5 LIGHT THE PILOT SEE LIGHTING INSTRUCTIONS TURN VALVE TO ON THE PRESSURE SE...

Страница 13: ...ady and not lifting off the burner holes The logs should not have any sooting black areas If there is a problem call an authorised gas fitter or your local dealer 4 The appliance and flue system must...

Страница 14: ...VIEW Realistic 5000L P Spare Parts Spare parts are available from your supplier Refer to rear of this manual for contact details 1 2 3 4 5 6 7 8 9 10 1 Firebox body main 2 Fascia 3 Top grill assembly...

Страница 15: ...e G a s L o g F i r e s INSTALLATION OF FASCIAS TRIMS FLOOR MOUNT FASCIA The Wall mounted fascia is attached to the outer case assembly by locating the fascia bottom tabs A over the outer case assemb...

Страница 16: ...a d e G a s L o g F i r e s INSTALLATION OF FASCIAS FLOOR MOUNT FASCIA The Floor mount fascia is attached to the outer case assembly by locating the fascia bottom tabs A over the outer case assembly...

Страница 17: ...ent and energy saving method of operating the fan SHUT DOWN It will also shut down the fan 10 to 15 minutes after the heater is turned off once the firebox has cooled sufficiently REMOTE CONTROLLER OP...

Страница 18: ...ONCE TO SWITCH ON MODE BUTTON PRESS THE MODE BUTTON TO CHANGE THE DESIRED TEMPERATURE LEVEL SET PRESS THE SET BUTTON TO SET THE TEMPERATURE BATTERIES THIS REMOTE HAND UNIT USES 2 AAA BATTERIES THAT CA...

Страница 19: ...tion is not active SOLUTION The gas valve sensor Thermopile may be faulty Contact your Dealer SYMPTOM The logs have a build up of black soot in some areas POSSIBLE CAUSE Usually indicates incorrect po...

Страница 20: ...ting it up then towards you See Below 2 Open the bottom door then lift up and slide the door back into the cavity then angle and remove one end first See Below 3 Remove the main door trim including sa...

Страница 21: ...ructions on gas pressure adjustment 7 Gas train assembly cover removal Remove horizontal screws phillips from rear wall as shown A Remove vertical screws from burner bracket B C Lift up gas train cove...

Страница 22: ...in North Rd Enfield SA 5084 Phone 08 8359 8300 By Phone Call our head office on 03 9793 7520 By Fax Faxes should be sent to 03 9793 6816 Manufactured by Illusion Australia Pty Ltd Head Office and Show...

Отзывы: