4
REALISTIC GAS MANUAL APRIL 14414 DB
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s
Main Gas Connection
The connection is made using gas pipes with Rp1/2 ISO 7 threading. Torque: 25Nm
If, alternatively, fl anges are used, fi rst screw the pipes on to the fl anges and then the
fl anges to the valve. Recommended torque for the fl ange fi xing screws: 3Nm.
I
t is recommended that a Certifi ed shutoff valve be fi tted between the incoming gas line and the appliance to
enable the gas supply to the appliance to be shut off independantly from the mains gas supply.
Caution: After making the connections, check gas tightness.
IMPORTANT NOTE TO INSTALLER
Caution:
Check the appliance before leaving.
Check that logs are correctly located. Incorrect location of logs
will affect combustion and may cause sooting.
Check the gas pressure.
Light the appliance and check for fl ame abnormalities on both high and low fl ame
settings. Flames should not lift off the burner ports. Allow the unit about 5 minutes to
warm up then if the fl ames are lifting from the burner ports it may be necessary to
adjust the gas pressure on the gas valve.
THE FOLLOWING INDICATES SITUATIONS OF ABNORMAL OPERATION OF THE APPLIANCE.
WHEN THE APPLIANCE IS OPERATING :
1. The
fl ames appear excessively large and / or sooting occurs on the logs.
2. You can smell gas.
3. The
fl ame pattern is inconsistent and appears to be lifting off the burner.
4. You can smell the products of the fl ue within the room in which the appliance is installed. (May be an
indication of a blocked fl ue)
If any of the above situations occur, turn the appliance off, and contact your supplier or installer
immediately. If you can smell gas, turn the gas off at the mains and call the appropriate authority.
Always call from outside the building from a neighbors, or with a mobile phone.
ABNORMAL OPERATION
Manufactured by Illusion Australia Pty. Ltd. 145 Sth. Gippsland Hwy Dandenong
Sth. 3175 Victoria Australia
Phone: 613 9793 7520 Fax: 613 9793 7530
ILLUSION GAS LOG FIRES - MODELS REALISTIC 5000L-NG, REALISTIC 5000P-NG
NOTE: TABLE BELOW RELATES TO ALL VARIATIONS OF EACH SIZE APPLIANCE
SAI GLOBAL APPROVAL CERTIFICATE NOS
:
TBA
Electrical components conform to AS 3100 240V 50hz 60 watts
Model
REALISTIC-5000L/NG
REALISTIC-5000P/NG
Injector
Size
2.90
2.4
Nominal Gas Consumption Mj/h
40.0
29.0
Gas Type
NAT
NAT
Turndown Pressure kPa
.46
.54
Manifold Pressure kPa
.90
.90
Kilowatt Rating (Vertical Flue) On High 6.34kw
5.1kw