REALISTIC GAS  MANUAL APRIL 14414 DB

I l l u s i o n - A u s t r a l i a n   M a d e   G a s   L o g   F i r e s

Main Gas Connection

The connection is made using gas pipes with Rp1/2 ISO 7 threading. Torque: 25Nm
If, alternatively, fl anges are used, fi rst screw the pipes on to the fl anges and then the
fl anges to the valve. Recommended torque for the fl ange fi xing screws: 3Nm.
I

t is recommended that a Certifi ed shutoff valve be fi tted  between the incoming gas line and the appliance to 

enable the gas supply to the appliance to be shut off independantly from the mains gas supply.
Caution: After making the connections, check gas tightness.

IMPORTANT NOTE TO INSTALLER
Caution:

          Check the appliance before leaving.

 

 

Check that logs  are correctly located.  Incorrect location of logs    

 

 

 

 

 

 

will affect combustion and may cause sooting.

 

 

Check the gas pressure. 

 

 

Light the appliance and check for fl ame abnormalities on both high and low fl ame  

 

 

 

 

settings. Flames should not lift off the burner ports. Allow the unit about 5 minutes to  

 

 

 

 

warm up then if the fl ames are lifting from the burner ports it may be necessary to  

 

 

 

 

adjust the gas pressure on the gas valve.

THE FOLLOWING  INDICATES SITUATIONS OF  ABNORMAL OPERATION OF THE APPLIANCE.   
WHEN THE APPLIANCE IS OPERATING :

1. The 

fl ames appear excessively large and / or  sooting occurs on the logs. 

2.  You can smell gas.
3. The 

fl ame pattern is inconsistent and appears to be lifting off the burner.

4.  You can smell  the products of the fl ue within the room in which the appliance is installed. (May be an 

indication of a blocked fl ue)

If any of the above  situations occur, turn the   appliance off,  and contact your supplier or installer   
immediately. If you can smell gas, turn the gas off at the mains and call the appropriate authority. 
Always call from outside the building from a neighbors, or with a mobile phone.

ABNORMAL OPERATION

Manufactured by Illusion Australia Pty. Ltd. 145 Sth. Gippsland Hwy Dandenong 

Sth.  3175 Victoria Australia

Phone: 613 9793 7520 Fax: 613 9793 7530

ILLUSION GAS LOG FIRES - MODELS REALISTIC 5000L-NG, REALISTIC 5000P-NG

NOTE: TABLE BELOW RELATES TO ALL VARIATIONS OF EACH SIZE APPLIANCE 

 

SAI GLOBAL APPROVAL CERTIFICATE NOS

:

 TBA

Electrical components conform to AS 3100     240V 50hz 60  watts

Model 

   REALISTIC-5000L/NG 

 REALISTIC-5000P/NG

   

 

 

Injector 

Size 

    

 

 

 

 

2.90 

  2.4 

   

 

Nominal Gas Consumption Mj/h  

      40.0  

 

29.0 

 

 

 

 

Gas Type 

 

 

 

      NAT  

 

NAT 

              

 

 

Turndown Pressure kPa  

 

      .46   

 

.54 

 

 

Manifold Pressure kPa   

 

      .90   

 

.90 

 

 

Kilowatt Rating  (Vertical Flue) On High       6.34kw 

 

5.1kw   

 

Содержание Realistic 5000L

Страница 1: ...tion as described in this manual and have been certified by SAI GLOBAL WARNING DO NOT MODIFY THIS APPLIANCE All Illusion Gas Log Appliances MUST be installed and serviced by an authorised person Unaut...

Страница 2: ...Log Fireplace has been fully tested and certified to Australian Standards NOTE Realistic GAS LOG FIREPLACES MODELS 5000L 5000 P ARE DESIGNED TO BE INSTALLED IN A SUITABLY CONSTRUCTED WALL OR FIREPLACE...

Страница 3: ...IMPORTANT Allow min 150mm up from floor when fitting standard window fascia and extra if skirting is fitted to the wall IMPORTANT Realistic MODEL HEIGHT Y MIN WIDTH X MIN DEPTH Z MIN 5000P 780m 920mm...

Страница 4: ...valve THE FOLLOWING INDICATES SITUATIONS OF ABNORMAL OPERATION OF THE APPLIANCE WHEN THE APPLIANCE IS OPERATING 1 The flames appear excessively large and or sooting occurs on the logs 2 You can smell...

Страница 5: ...ates a live fuel effect which is designed to operate with luminous flames and may exhibit slight carbon deposition PILOT FLAME IGNITION Depress and turn the control knob to the PILOT position Depress...

Страница 6: ...Y GUARD THE Realistic GAS LOG FIRE IS SUPPLIED WITH A PRIMARY GUARD FOR YOUR PROTECTION THE PRIMARY GUARD MUST BE FITTED WHEN THE UNIT IS OPERATING THE GLASS FRONT OF THE APPLIANCE IS EXTREMELY HOT WH...

Страница 7: ...THE APPLIANCE TOP AND THE CEILING 1 These appliances must be installed in accordance with the regulations municipal building codes and AS NZS 5601 GAS INSTALLATIONS 2 Only an Authorised person shall i...

Страница 8: ...OLLOWS MINIMUM DIAMETER OF ACTIVE FLUE ALL MODELS IS 127MM A 127mm STAINLESS STEEL FLUE PIPE IS USED FOR THE FIRST LENGTH OF ACTIVE FLUE PIPE GALVANISED FLUE PIPE IS USED FOR SUBSEQUENT LENGTHS THE MI...

Страница 9: ...T EDITION FIRST LENGTH OF ACTIVE FLUE PIPE IS STAINLESS STEEL ALL OTHERS ARE GALVANISED The maximum recommended flue length is 3 6m The recommended minimum distance from the top of the heater to the u...

Страница 10: ...s i o n A u s t r a l i a n M a d e G a s L o g F i r e s INSTALLATION OPTION 2 INTO EXISTING CHIMNEY VERTICALLY PLEASE NOTE ALL ILLusion GAS LOG FIRES MUST BE INSTALLED BY AN AUTHORISED PERSON IN ACC...

Страница 11: ...e side front log overlaps the left hand side front log 6 Fit the right hand side front log No 7 onto the pins in the front of the grate as shown H FITTING THE LOGS WHEN INSTALLING LOGS ENSURE THAT BUR...

Страница 12: ...N THE GAS VALVE PROCEDURE TURN VALVE TO OFF POSITION LOOSEN INLET PRESSURE POINT 5 ATTACH MANOMETER TO INLET PRESSURE POINT 5 LIGHT THE PILOT SEE LIGHTING INSTRUCTIONS TURN VALVE TO ON THE PRESSURE SE...

Страница 13: ...ady and not lifting off the burner holes The logs should not have any sooting black areas If there is a problem call an authorised gas fitter or your local dealer 4 The appliance and flue system must...

Страница 14: ...VIEW Realistic 5000L P Spare Parts Spare parts are available from your supplier Refer to rear of this manual for contact details 1 2 3 4 5 6 7 8 9 10 1 Firebox body main 2 Fascia 3 Top grill assembly...

Страница 15: ...e G a s L o g F i r e s INSTALLATION OF FASCIAS TRIMS FLOOR MOUNT FASCIA The Wall mounted fascia is attached to the outer case assembly by locating the fascia bottom tabs A over the outer case assemb...

Страница 16: ...a d e G a s L o g F i r e s INSTALLATION OF FASCIAS FLOOR MOUNT FASCIA The Floor mount fascia is attached to the outer case assembly by locating the fascia bottom tabs A over the outer case assembly...

Страница 17: ...ent and energy saving method of operating the fan SHUT DOWN It will also shut down the fan 10 to 15 minutes after the heater is turned off once the firebox has cooled sufficiently REMOTE CONTROLLER OP...

Страница 18: ...ONCE TO SWITCH ON MODE BUTTON PRESS THE MODE BUTTON TO CHANGE THE DESIRED TEMPERATURE LEVEL SET PRESS THE SET BUTTON TO SET THE TEMPERATURE BATTERIES THIS REMOTE HAND UNIT USES 2 AAA BATTERIES THAT CA...

Страница 19: ...tion is not active SOLUTION The gas valve sensor Thermopile may be faulty Contact your Dealer SYMPTOM The logs have a build up of black soot in some areas POSSIBLE CAUSE Usually indicates incorrect po...

Страница 20: ...ting it up then towards you See Below 2 Open the bottom door then lift up and slide the door back into the cavity then angle and remove one end first See Below 3 Remove the main door trim including sa...

Страница 21: ...ructions on gas pressure adjustment 7 Gas train assembly cover removal Remove horizontal screws phillips from rear wall as shown A Remove vertical screws from burner bracket B C Lift up gas train cove...

Страница 22: ...in North Rd Enfield SA 5084 Phone 08 8359 8300 By Phone Call our head office on 03 9793 7520 By Fax Faxes should be sent to 03 9793 6816 Manufactured by Illusion Australia Pty Ltd Head Office and Show...

Отзывы: