background image

 

 

 

12 

Instruction Manual 

 
 
 
 
 

Published by ILLUCO Corporation Ltd. 

Copyright ©  2018 by ILLUCO Corporation Ltd. 

104-505 SK Ventium, #166 Gosan-ro, Gunpo-si 

15850 Gyeonggi-do, Republic of Korea 

Tel: +82 31-429-8825 
Int’l: +82 70 4922 7441 
Fax: +82 31-429-8826 
Website: http://www.illuco.co.kr 
E-mail: 

[email protected]

 

 
 

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or 

transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, 

without the prior permission of ILLUCO Corporation Ltd. 

 

 

 

 

 

Printed in Republic of Korea 

 

Содержание IDS-3100

Страница 1: ...Quality made by ILLUCO www illuco co kr ...

Страница 2: ...formation Safety precautions 3 Symbols Key 4 Specifications Magnum UV IDS 3100 5 Parts Description 6 Directions for Use 7 Battery and Charging 8 Automatic shut down 9 Maintenance 9 Troubleshooting Guide 9 EC DECLARATION OF CONFORMITY 10 IDS SERIES LIMITED WARRANTY 11 ...

Страница 3: ... Moreover IDS 3100 has completely resolved the weakness of the existing UV LED Magnifiers and shows perfectly reflected light fluorescence The IDS 3100 is simple to use but its performance is stronger than any existing wood s lamps Secondarily IDS 3100 is equipped with polarized non polarized light modes allowing simple examinations of pigmented skin lesions prior to precise analysis using a derma...

Страница 4: ...ht Patients must close their eyes during facial examinations IDS 3100 has a Lithium ion battery embedded Handle it carefully to prevent damage from an external shock Also do not use and store IDS 3100 in abnormally hot or cold climates Do not look at the sun through the objective lens as it will cause blindness Avoid direct sun ray passing through the lens The lens can potentially focus sunlight t...

Страница 5: ...to the device Clean the device frequently Near heating devices Do not place the device near a heating device Do not open or dismantle The manufacturer will not be responsible for any errors or damage whatsoever caused by opening or dismantling the device Symbols Key Do not look directly at LED light Power on off button Charging Status D Brightness Control Button Cross parallel polarized light mode...

Страница 6: ...tive Focal length Bet Lens Skin 65 140mm wide range of effective distance Resolution 23 LP Color Correction Anti reflection coating Wide BBAR specially designed coating for enhanced lens protection and UV transmittance Intensity of Illumination High SMD Type 3500 4000 Lux LED 64 White LED 6 UV LED LED Life 100 000 Hours Battery Rechargeable Lithium ion 3400mAh 3 7v Protection Circuit Module embedd...

Страница 7: ...on 1 Objective Lens 2 Polarization UV Mode indicator Charging status indicator 3 Power button 4 UV mode button 5 Polarized mode button 6 Brightness Control button 7 Charging port 8 Battery Cover 9 LED part 10 Charging cradle optional part ...

Страница 8: ...m 395nm UV Light Examination UV Indication light Blue Push the UV button with intention of UV light examination In order to change the UV mode 365nm UV 395nm UV push the UV button one more time Adjust your eyes to the objective lens IDS 3100 is designed for using both eyes for observation It means you don t need to close one eye to take a closer look at the lesion To brighten up or down the LED la...

Страница 9: ...is in charging status Green Charging completed B Charging via USB charging outlet Prepare the USB charging outlet supplied with IDS 3100 Insert the USB charging outlet into the charging port of the device and the USB plug into an USB charging outlet Note Using a USB port of a PC is not recommended as it will take over 10 hours until the unit is fully charged C Charging via Charging cradle Connect ...

Страница 10: ...ve Alcohol and Acetone are different Don t be confused and never use acetone for device cleaning incl objective lens Troubleshooting Guide Note IDS 3100 is reliable and designed for trouble free operation Never attempt to open or dismantle the device for any reason other than battery replacement The manufacturer and distributors are not liable for mechanical troubles property damage or personal in...

Страница 11: ... of Korea fulfills the essential requirements of the Medical Device Directive 93 42 EEC amended by 2007 47 EC and is registered in Class I according to Appendix IX Conformity is assured according to the guidelines set out in AppendixVII The Product is produced in accordance with harmonized standards and Conformity is assured according to the guidelines set out in AppendixVII The product carries th...

Страница 12: ... technician f Damage or malfunctions resulting from natural calamity freezing theft accident vandalism abuse due to misapplication and or improper site conditions SPECIFIC EXCLUSIONS Items not covered under warranty include a Parts replaced due to normal wear or routine maintenance including but not limited to battery LEDs protect glass etc b Consumable or wearing items requiring replacement as pa...

Страница 13: ...1 429 8825 Int l 82 70 4922 7441 Fax 82 31 429 8826 Website http www illuco co kr E mail info illuco co kr All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior permission of ILLUCO Corporation Ltd Printed in Republic of Korea ...