1.

 

Introduction 

The  alarm controller is designed to work with PC based DVR (Hybrid DVR Server) and analog matrix 

system.  In fact there is no hardware device of ALM-3232. It is only a kind of software name.  You can 

combine 2 pieces of ALM-1616 to build up ALM-3232 via first device ID=1 and second device ID=2. 

 

1.1

 

Input port 

16 ports input for ILDVR-1608, 8 ports input for ILDVR-0808

 

 

IN – Sensor Data +                         I-COM – Sensor Data -   

ID – Device ID (Alarm controller address)      CODE – RS485 port 

DC12V – 12V DC Power                   ALARMS-IN indicator – Flashes when connects a sensor 

 

1.2

 

Output port. 

 

 

NO – Normal Open connecter         C – COM connecter 

NC – Normal Close connecter         ALARMS OUT indicator – Flashes when there is an alarm 

 

1.3

 

Specifications 

 

Power Supply:

  ALM-0808 is DC12V/8W, ALM-1608 is DC12V/12W, ALM-1616 is AC220V/10W or 

AC110V/ 10W 

DI Port:

 N/C or N/O   

DO Port: 

N/C or N/O 

Output: 

10A/DC28V or 7A/AC220V 

Working Temperature: 

-10

 

- 55

 

Humidity: 

90% RH

 

Dimension: 

ALM-0808/1608 is 182×120×30mm, ALM-1616 is 484×300×15.5mm 