Cinemage User Manual
Version 4.1.x ©2010
Power Requirements for Cinemage
Cinemage runs on 100 to 240V AC at 50 or 60 hertz. Nominal current is 2A.
[OPTION]
If you have the DC input option installed you may run the system on 22-30V DC
input. Standard Anton Bauer 3 pin XLR connector is used. Pin 1 is ground, Pin 2 is
positive and Pin 3 is unused.
The main disconnect for the Cinemage system is the power connector on the real panel
of the system. The input supply socket-outlet should be located near the device and
should be easily accessible.
Power Requirements for Cinemage B Series (B420, B230, B190)
Cinemage B420 runs on - - -
Cinemage B230 runs on 100 to 240V AC at 50 or 60 hertz. Nominal current is 2A.
[OPTION]
If you have the DC input option installed you may run the system on 10-15V DC
input. Standard Anton Bauer 3 pin XLR connector is used. Pin 1 is ground, Pin 2 is
positive and Pin 3 is unused.
The main disconnect for the Cinemage B230 system is the power connector on the real
panel of the system. The input supply socket-outlet should be located near the device
and should be easily accessible.
Cinemage B190 runs on - - -
User Serviceable Parts
There are no user serviceable parts inside the Cinemage or Cinemage B Series units.
Please refer all service to a Cine-tal authorized technician. The Cinemage monitor and
Cinemage B Series monitors front housing is made to be removed for the cleaning of
the neutral density filter and LCD display. This action can be performed by the end user
or customer.
Instructions on how to remove the front bezel on the Cinemage
:
1) Lay the monitor down on its back, with the glass facing up.
2) If you are facing the front of the monitor, there are three screws that need to
be removed from the left side (side with inputs) along the front of the housing
(side closest to the glass).
3) Next, there are five screws that need to be removed from the top of the
monitor.