151
Cinemage User Manual
Version 4.1.x ©2010
graphics adapter. The system uses this information for configuration purposes, so the monitor and computer system
can work together. Cinemage systems shipped before December 1, 2006 did not have the EDID set in DVI input
chipsets (see Setting EDID). If you are using an operating system in your computer that allows manual settings for
monitor support you should set them to:
Pixel Clk:
154
V Active Lines:
1200
H Active Pix:
1920
V Blank:
35
H Blank:
160
V Sync Offset:
3
H Sync Offset:
48
V Sync Width:
6
H Sync Width:
32
V Image Size:
324
H Image Size:
519
V Border:
0
H border:
0
Min V Rate:
56 Hz
Min H Rate:
30 KHz
Max V Rate:
76 Hz
Max H Rate:
81 KHz
Max PxlClk:
170 MHz
Setting EDID
Although it is not required to use the DVI input, customers with Cinemage units shipped before December 1, 2006
may want to setup the EDID on their systems. Setting the EDID is accomplished with a field update kit available for
loan from Cine-tal. The EDID update kit allows customers to set their EDID without returning the units to the
factory. The update kit includes a special DVI cable and WindowsXP based software. System requirements are a
WindowsXP based system with a standard RS232 Serial Port. Customers may also return units to Cine-tal for EDID
settings. Contact Cine-tal Customer Service (01-317-576-0091) or ([email protected]) to determine the best
method for you.