background image

15

Useful information

The 

station

 is controlled via a 

WiCo

� If the 

WiCo

 is 

mounted on the 

station

, data is exchanged between the 

station

 and 

WiCo

 via the contacts (C)� The screen of the 

WiCo

 displays the home icon  � 

The 

WiCo

 is equipped with a USB socket (Universal Serial 

Bus) with which the 

WiCo

 can be connected with 

station

the USB icon 

 appears on the screen� 

If the 

WiCo

 is not connected with 

station

 via a USB 

cable, the data exchange between the 

station

 and the 

WiCo

 via Bluetooth

®

� In this case, the Bluetooth

®

 icon   

is displayed �

Depending on the structure of the building, the 

WiCo

 can 

be operated at a distance up to 15 m from the 

station

using the Bluetooth

®

 connection�

The 

WiCo

 could be either installed on the 

station

 or put 

on a safe place where is accessed easily by the user during 
operation� 
If the 

WiCo

 is mounted on the 

station

, the battery is 

charged through the contacts (C)� 
The battery could also be charged via the USB port on the 

WiCo

 (See “Charging the Battery Pack RB 1“ in “Prepara-

tions“ section)�

 Working with WiCo

Working screen at the time of delivery:

Fig. 21

Explanation of symbols on the working screen:

The symbols displayed change depending on the status 
and settings of the 

WiCo 

and the

 station

� The screen 

below shows the most significant symbols on the working 
screen�

 

Bluetooth

®

This symbol means the 

station

 and the 

WiCo

 are com-

municating via Bluetooth

®

� 

The symbol no longer appears if no Bluetooth

®

 communi-

cation is being performed�

99 

Device number:

This figure appears when the “Device Number“ is activat-
ed in menu option “Display“�
The figure can be set from 0 to 99�
See section “Display“ under “Menu (Details)“�

  

Lock:

 

This symbol means that the function of the keys and the 
rotary knobs for controlling the 

WiCo

 are disabled� 

The symbol no longer appears if the functions are enabled 
once again by pressing the key button a second time�

 

Temperature Sensor:

This symbol appears when the external temperature sen-
sor is connected�

A

  

Operating Mode: 

This symbol indicates the operating mode currently selected 
(A, B, C, D)�

  

USB: 

This symbol means the 

WiCo

 is communicating or the 

battery is charged via a USB cable� The symbol no longer 
appears if no USB cable is being used for communicating 
with the 

station

  

Home: 

This symbol means that the 

WiCo

 is connected to the 

station

 and is communicating with the 

station

 via the 

contacts� 
The symbol no longer appears if the 

WiCo

 is removed 

from the 

station

� 

A

0�00

int °C

ext °C

int

5�00

2000

set °C

Pump rpm

Fig. 22

A

99

10�00

int °C

ext °C

int

10�00

2000

set °C

Pump rpm

PC

10�00

Note: 

The wireless symbol   appears only when the 

sta-

tion

 is switched on� 

Содержание RC 2 GREEN control

Страница 1: ...Operating instructions EN IKA RC 2 GREEN control...

Страница 2: ...ig 1 Item Designation 1 Filling opening lid 2 Wireless Controller WiCo 3 Handle 4 Venting grid 5 RS 232 port 6 USB port 7 External temperature sensor socket 8 Pump connector IN 9 Pump connector OUT 10...

Страница 3: ...g battery into the WiCo 9 Mounting the WiCo to the station 9 Filling and draining 9 Fluids Standard information for IKA fluid 11 Moving the device 12 Charging the Battery Pack RB 1 rechargeable batter...

Страница 4: ...nse exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause...

Страница 5: ...on the device again to ensure safe operation for example to keep foreign ob jects and liquids etc from getting into the device The device may only be used as prescribed and as de scribed in these ope...

Страница 6: ...OFF key and the Power switch Please note the following safety instructions for the battery pack RB 1 recharge able battery Keep the battery pack out of reach of children at all times Store the batter...

Страница 7: ...k between the WiCo and the laboratory device first check whether your region is in cluded in the radio communication approval for the de vice If it is not remote control can also be performed using a...

Страница 8: ...he cooling system Connecting the tubings Unscrew the union nuts and stoppers using a wrench AF 19 from the pump connector IN 8 and OUT 9 Connect the hoses for circulating the external system to the pu...

Страница 9: ...w cap Inserting battery into the WiCo Model WiCo CBC 5 LPS IP 40 Model WiCo CBC 5 LPS IP 40 Model WiCo CBC 5 LPS IP 40 Note notch upward Model WiCo CBC 5 LPS IP 40 Model WiCo CBC 5 LPS IP 40 Fig 7 Scr...

Страница 10: ...ckwise to the stop position see Fig 10 Note Please note information in section Commissioning Connect the power plug and turn on the device with power switch 10 The low level icon appears on the displa...

Страница 11: ...perature Maximum temperature N Negative Temperature 4 Viscosiy Viscosiy at 25 C for Heating Fluid HF Viscosity at 20 C for Cooling Fluid CF Viscosity at 25 C for Universal Fluid UF Dynamic viscosity m...

Страница 12: ...ss head clamp H 38 Holding rod IKA RC 2 GREENcontrol IKA RC 2 GREEN control IKA RC 2 GREENcontrol Moving the device Empty all fluid in the bath before move device from one place to other place The dev...

Страница 13: ...gh Low Fluid level 2 GREEN Fig 16 A F D E B C Item Designation Function L On Off button Switch the WiCo on and off M int ext button Switch between the internal and external temperature display and con...

Страница 14: ...nce The refrigerating function may delay to start at maximum 2 minutes In working status press the right knob R to stop opera tion of the pump The refrigerating function and the pump stops Note In sta...

Страница 15: ...and the station The screen below shows the most significant symbols on the working screen Bluetooth This symbol means the station and the WiCo are com municating via Bluetooth The symbol no longer app...

Страница 16: ...he menu by turning the right rotating pressing knob R to the right or left Open the menu item by pressing the right rotating pressing knob R Turn the rotating pressing knob R to select the desired men...

Страница 17: ...omized 1 Customized 2 PUMP Limits Speed Pressure Maximum Maximum Minimum 4000 rpm 2000 rpm 0 5 bar TIMER Set Display 00 00 hh mm MODE A C B D activated GRAPH Automatic Manual Axis Assignment Set Tempe...

Страница 18: ...e difference between the external system and internal bath during the heating up and cooling down process This can protects sensitive device like the glass reactors from thermal shock e g glass break...

Страница 19: ...Step 1 2 Enter the temperature from the measuring device 32 00 OC OK Calibration Internal 2 Point Calibration Step 1 2 Enter the temperature from the measuring device 32 00 OC OK Calibration Internal...

Страница 20: ...d or set PROGRAMS Under programs 10 user defined temperature time pro files can be created A program can consist of up to 10 segments Once a program has been selected the following options are availab...

Страница 21: ...button re sets all the system settings to the original standard values set at dispatch from the factory see Menu structure 5 Communication The Device name menu option allows you to edit the device na...

Страница 22: ...top mode Type of transmission full duplex Character format character representation in accordance with data format in DIN 66 022 for start stop mode 1 start bit 7 character bits 1 parity bit even 1 st...

Страница 23: ...1 and set the time for the watchdog to n 20 1500 seconds Echo of the Watchdog time During a WD1 event the cooling and pump functions are switched off and message PC 1 is display This command needs to...

Страница 24: ...o A USB micro B USB micro A Connection the device to PC USB micro B USB A USB micro B USB A RS 232 USB or USB micro B USB A Fig 32 USB cable RS 232 USB or USB micro B USB A 9 pin RS 232 9 pin RS 232 A...

Страница 25: ...alcohol Wear protective gloves while cleaning the instruments Electrical instruments may not be placed in the cleansing agent for the purpose of cleaning Do not allow moisture to get into the instrume...

Страница 26: ...impeller is blocked Error 06 Pump off Refrigerating off Too low liquid level Check the liquid level and buoyage Error 10 Pump off Refrigerating off PC communication failure Check communication cable E...

Страница 27: ...h 12 H SI 8 Silicone hose nominal width 8 H SI 12 Silicone hose nominal width 12 H PUR 8 PUR tube nominal width 8 mm H PUR 12 PUR tube nominal width 12 mm H FKM 8 FKM tube nominal width 8 mm H FKM 12...

Страница 28: ...Knob on WiCo Temperature setting resolution K 0 1 Temperature display TFT LCD on WiCo Temperature display resolution K 0 01 Cooling capacity according to DIN 12876 at 4000 rpm 20 C 10 C 0 C 10 C 20 C...

Страница 29: ...ranty conditions the warranty period is 24 months For claims under the warranty please contact your local dealer You may also send the machine direct to our factory enclosing the delivery invoice and...

Страница 30: ...es england ika com MALAYSIA IKA Works Asia Sdn Bhd Phone 60 3 6099 5666 eMail sales lab ika my CHINA IKA Works Guangzhou Phone 86 20 8222 6771 eMail info ika cn POLAND IKA Poland Sp z o o Phone 48 22...

Отзывы: