AMM36 • SSI, BiSS, & RS-485
Step 5
Rotate the motor shaft until the code disk
3
is aligned with the encoder unit
5
as shown in the Figure; the mark
8
punched in the code disk
3
must be centred
in the encoder unit
5
as shown in the Figure. Max. misalignment allowed: ± 10
mechanical degrees.
WARNING
If you do not align the code disk
3
with the encoder unit
5
, the encoder will
send back an error at power-on. Should this happen, switch the power supply
off, align the code disk
3
properly and then proceed again as explained in the
next step.
Step 6
Connect the
EC000026
cable to the Hirose connector
9
of the encoder unit
5
.
Please make sure that the power supply is off and the battery is not wired
before connecting the cable.
Step 7
Connect the battery.
Step 8
Switch the power supply on. The LEDs will blink for a while and then go off, if
the installation procedure is successful.
If at the end of the operation a LED is still on, please repeat the procedure again.
Refer also to the “9 - Diagnostic LEDs” section on page 51.