![Ihse Draco vario 486 Series Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/ihse/draco-vario-486-series/draco-vario-486-series_user-manual_623598041.webp)
Specifications
2021-07-06
41
You can use a delay for converting the sample rate. The time is set in
milliseconds and separated from the parameter for the sample rate by
a semicolon (e.g.
SRC44100;12
). You can set the following delays for
the sample rates:
– 32.0 kHz: 3 - 60 ms
– 44.1 kHz: 2 - 44 ms
– 48.0 kHz: 2 - 40 ms
– 96.0 kHz: 1 - 20 ms
To deactivate the sample rate converter, write
SRC_NONE
in the
Config.txt file of the CPU unit.
Compatibility
AES/EBU, S/PDIF, EIAJ CP1201,
IEC 60958
Standards
Dolby Digital, DTS, PCM
Bit Depth
24 bit
Sample Rate
32 to 96 kHz
CPU Unit (Inputs)
Mini-XLR (AES/EBU; symmetrical,
lockable)
Coaxial (S/PDIF; RCA, Cinch)
Optical (S/PDIF; TOSLINK)
CON Unit (Outputs)
Mini-XLR (AES/EBU; symmetrical,
lockable)
Coaxial (S/PDIF; RCA, Cinch)
Optical (S/PDIF; TOSLINK)
For testing purposes it is possible to generate a sinus tone on the digital
audio input module. In order to do so you have to set Jumper 1 on the
respective input module.
Pos: 49 /806-IHSE/Technische Daten/Schnittstellen/474-xx (Symmetrische Audio-Schnittstelle) @ 15\mod_1446727949950_6.doc @ 165055 @ 3 @ 1
7.1.6 Balanced Audio Interface
SDI Extenders with a balanced audio interface support a unidirectional
2-channel mono or 1-channel stereo transmission in studio quality.
The audio interface is at the same time a 'Line-Level' and 'Mic-Level'
interface and is designed to transmit signals of a microphone or mixing
desk for example with a high tolerance for interferences, even at larger
distances. In addition to that you can connect active speakers at the CON
Unit.