Draco tera
116
2014-04-15
7. The USB 2.0 CPU extenders now has to be either assigned to an
existing CON Device in the
Definition > CPU Devices
menu or a
new CON Device has to be created for the assignment by pressing
the
New
button.
8. If you use parallel operation within the matrix, set the
Release Time
in the
Configuration > Switch
menu to
10 s
or more (see
Chapter
9. Restart all I/O boards on which USB 2.0 extenders have been
configured or alternatively restart the matrix.
The USB 2.0 extenders are now configured and can be used.
Created extender units are always set as fixed port extenders. This
configuration is necessary if you want to switch e.g. USB 2.0 connections
via the matrix.
In order to make a fixed port available again for Flex-Port extender units
after deleting a fixed port extender unit, a restart of the I/O board is
necessary.
Pos: 78 /806-IHSE/Konfiguration/480_CPU-Einstellungen/480-xx @ 7\mod_1309938442055_6.doc @ 53216 @ 2 @ 1
5.8
CPU Settings
New CPU devices are configured in this menu including their assignment
to extenders.
The assignment helps to describe and switch more complex computer
configurations (e.g. Quad-Head with USB 2.0) in the matrix.
You have the following options to access the menu:
You can select the following settings:
Field
Selection
Description
ID
Text
ID of the CPU Unit (see Chapter
Page 82).
Name
Text
Name of the CPU Device.
activated
Create new CPU Device as a virtual one.
Virtual Device
deactivated Function not active (default).