8.3.1.2 Starting and Exiting the Command Mode
Keyboard command
Function
2x Left Shift
Start the command mode (Hot Key, factory setting).
Esc
Exit the command mode.
8.3.1.3 Opening and Exiting the OSD
Keyboard command
Function
Hot Key, o
Open the OSD.
Fast Key
Hot Key, s, o
Open OSD of the sub matrix in a cascaded environment.
Esc
Exit the OSD in the main menu or go back one step in the menu structure.
Left Shift + Esc
Exit the OSD within the menus.
Left Ctrl + Esc
8.3.1.4 Switching the USB-HID Control
Keyboard command
Function
Hot Key, Num0
Switch the USB-HID control to the CPU Device connected to the user’s CON
Device.
Hot Key, Num1
Switch the USB-HID control to the CPU Device connected to the CON Device
with monitor display 1.
Hot Key, Num2
Switch the USB-HID control to the CPU Device connected to the CON Device
with monitor display 2.
Hot Key, Num3
Switch the USB-HID control to the CPU Device connected to the CON Device
with monitor display 3.
Hot Key, Num4
Switch the USB-HID control to the CPU Device connected to the CON Device
with monitor display 4.
8.3.2 Managing of the EDID and USB-HID Ghosting
8.3.2.1 EDID
Keyboard command
Function
Hot Key, a
Download the EDID of a monitor connected to the CON Unit into the associated
CPU Unit.
8.3.2.2 USB-HID Ghosting
Keyboard command
Function
Hot Key, h, w, Enter
Write the device descriptions of the input devices connected to the CON Unit
into the CPU Unit. Activate the emulation of these device descriptions in the
CPU Unit.
Hot Key, h, e, Enter
Activate the emulation of already stored device descriptions in the CPU Unit.
Hot Key, h, d, Enter
Deactivate the emulation of active device descriptions in the CPU Unit. The
input devices connected to the CON Unit will be now passed transparently to the
source.
Hot Key, h, r, Enter
Deactivate the emulation of active device descriptions in the CPU Unit. Deletes
the descriptions out of the CPU Unit. The input devices connected to the
CON Unit will be now passed transparently to the source.