![Ihse Draco tera enterprise 480 Series Скачать руководство пользователя страница 138](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699138.webp)
Configuration via OSD
Draco tera enterprise
138
7. Select
Configuration > System
in the main menu of the Sub Matrix.
7.1. Set the
Sub Matrix
option to
Y
.
7.2. Click
Okay
to confirm the Sub Matrix option.
The OSD of the Sub Matrix will immediately freeze and will be only accessible by using the keyboard
command Hot Key, s, o.
Fig. 91
OSD Menu
Configuration - System
8. Restart all I/O boards (see chapter 9.2.2, page 309) on which any Master/Sub CON Units or CPU Units
have been configured or alternatively restart the matrix (see chapter 9.2.1, page 308).
9. Connect the Tie Lines to the matrices. Ensure that each
Cascade CON Device
on one matrix is
connected to
Cascade CPU Device
on the other matrix to achieve switching ability between two
matrices.
The Matrix Cascading is now configured and can be used.
Additional Tie Lines are configured accordingly. The use of cascading is described in in chapter 8.1.1,
page 290.