24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
CAUTION: Wear gloves and safety glasses for protection while
doing required maintenance.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adéquatement une fois
l'entretien terminé.
Maintenance Checklist
The following should only be performed by a qualified service
technician.
1. Annual inspection should be made and the following checks per-
formed:
o
When unit is cool, remove glass and inspect burner for dirt, soot and
lint accumulations and remove if necessary. If excessive soot ac-
cumulation is present on burner, have a qualified service technician
adjust the burner for proper combustion.
o
Clean inside of glass with gas fireplace glass cleaner. NEVER attempt
to remove or clean the glass when the unit is hot.
o
Check the hot air outlet vents for lint or other accumulations. Never
block or restrict vent openings, obstruct flow of ventilation air, or use
vents other than those approved for use with this appliance.
o
Check that the chimney and its outlet are open and free of soot,
blockage, or debris.
IMPORTANT NOTE:
Prior to the first use of
the fireplace and each burn season and periodically during the
burn season, inspect the horizontal termination for debris such as
bird nests, leaves, paper or branches. Remove any items from the
surfaces of the termination prior to use. Also be aware of shrubs
and plantings that may encroach on the termination.
o
Check gaskets once a year. Gaskets must be tight. Replace if neces-
sary.
o
Inspect the pilot system for proper flame. NEVER ADJUST THE PILOT
until after the gas pressure has been checked and the supply lines have
been completely bled (this may take an hour or more when bleeding
through the pilot). All pilots are checked and burned at the factory
prior to shipment. The pilot adjustment screw is located below the
ON/OFF/PILOT control knob. Remove the pilot adjusting cover with
a flat-bladed screwdriver to access the pilot adjusting screw. Adjust
the pilot screw to properly size the flames. The flames should directly
contact the thermopile and extend across the main burner ports. Be
careful not to back the screw out of its threads. Replace the cover
and check for gas leaks using a gas leak test solution.
Millivolt and System Checks
Check
Test
To
Test
Connect
Meter
Leads to
Terminals
Thermostat
Connects
Meter Read-
ing
Should Be
A
Complete
System
2 & 3
Closed
100 MV
or More
B
Thermopile
Output
1 & 2
Open
Greater Than
325 MV
C
System
Resistance
2 & 3
Closed
2.5 Ohms
MAINTENANCE AND SERVICING
WARNING
Turn off gas and electrical power to the fireplace
and allow it to cool before cleaning or servicing
the appliance.
o
Check that the area around the insert is kept clear and is free of
combustible materials, gasoline and other flammable vapors and
liquids.
o
Check the millivolt system as per the table on this page.
2. The viewing glass should be cleaned periodically (see Glass Main-
tenance).
Figure 19
Proper Pilot Flame Appearance