IHP B10DM Series Скачать руководство пользователя страница 1

1

VENT-FREE BLUE FLAME 

GAS WALL HEATER

MODEL #(C)(GC)B10DT/B10DM(B)

(C)(GC)B20DT/B20DM(B)
(C)(GC)B30DT/B30DM(B)

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

WARNING: 

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED 

EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY 

DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

Questions, problems, missing parts?

 Before returning to your retailer, call our 

customer service department at 1-800-655-2008 or find us on the web at 

www.SuperiorFireplaces.US.com

       WARNING:

 This appliance is equipped for 

Natural and Propane gas. Field conversion is not 

permitted.

- Do not store or use gasoline or other flammable vapors and Iiquids in vicinity of this or 

  any other appliance.
  WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.

  • Do not touch any electrical switch; do not use any phone in your building.

  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s  

    instructions.

  • If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the 

   gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 

installed. Provisions for adequate combustion and ventilation air must be provided.

Refer to Air For Combustion and Ventilation section on page 8 of this manual.

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) 

home, where not prohibited by local codes. 

This appliance is only for use with propane or natural gas. 

This appliance is equipped with a simple means to switch between propane and natural gas. 

Field conversion by any other means including the use of a kit is not permitted.

C           US

       WARNING

: Do not attempt to access or 

change the setting of the fuel selection means.
Access to and adjustment of the fuel selection 
means must only be performed by a qualified 

service person when connecting this appliance to a 

specified fuel supply at the time of installation.
Change of the selector setting to other than the fuel 

type specified at the time of installation could dam-

age this appliance and render it inoperable.
The installer shall replace the access cover before 

completing the installation and operating this appli-

ance.

C           US

ANS Z21.11.2-2013

900269-02

Gas Fired Room Heaters

Volume II - Unvented Room Heaters

Содержание B10DM Series

Страница 1: ...lified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 8 of this manual This appliance may be installed in an aftermarket permanently located manufactured mobile home where not...

Страница 2: ......

Страница 3: ...et Gas Pressure Maximum 14 in W C 14 in W C Minimum For purposes of input adjustment 6 in W C 11 in W C Dimensions in H x W x D Height includes legs Weight lbs Fan Ratings Select Models Electronic Push Button B30DT B30DM B 120V 60Hz 18W 0 15A 24 0 in x 27 8 in x 10 0 in SERIES MAX BTU 10 000 10 000 20 000 20 000 MIN BTU 5 000 8 000 10 000 16 000 Fuel Type Natural Gas Propane Natural Gas Propane Ig...

Страница 4: ...e appliance Never place any objects on the heater WARNING Due to high temperatures locate this appliance out of traffic and away from furniture and draperies This appliance is intended for supplemental heating This appliance can be used with propane or natural gas It is shipped from the factory adjusted for use with propane CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning resembl...

Страница 5: ...off have it serviced 6 Do not run heater Where flammable liquids or vapors are used or stored Under dusty conditions 7 Before using furniture polish wax carpet cleaner or similar products turn heater and pilot off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immedi...

Страница 6: ...erature See page 24 FAN KIT SELECT MODELS The fan kit helps to distribute the warmed air into the space more rapidly State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the ...

Страница 7: ...ery 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplemental heat applications the water vapor does not create a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help ensure that water vapor does not become a prob...

Страница 8: ...e unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combusti...

Страница 9: ...BTU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU hr the space can support with the actual amount of BTU hr used _______ BTU h...

Страница 10: ... fresh air by using ventilation grills or duct You must provide two permanent openings one within 12 in of the ceiling and one within 12 in of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for required size of ventilation grill...

Страница 11: ...nstalling heater next to vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke candles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor CLEARANCES TO COMBUSTIBLES Carefully follow the instructions below This heater can be mounted on the wall or on the floor using the legs WARNING Maintain the minimum clearances shown in See F...

Страница 12: ... selector valve access panel NG TO LP CONVERSION 1 Before gas conversion remove screws and access panel for selector valve 2 The gas selector valve should be in the NG position Push and turn the selector knob clockwise until the knob locks into the LP position See Fig 4b The selector valve must be locked in the LP position DO NOT operate the heater between the locked positions 3 Remove plug from t...

Страница 13: ...crews using a screwdriver See Fig 9 Attach Fan to the rear panel of the heater using the four screws provided NOTE Be sure the rocker switch is positioned in the upper right corner See Fig 10 3 This fan is equipped with manual MAN and automatic AUTO settings See Fig 11 on page 13 Set the rocker switch to MAN for manual mode allowing the fan to continuously run until the rocker switch is returned t...

Страница 14: ... outside the table edge 2 Fasten Legs to heater using Support Leg Screws Fig 13 Note If the heater is to be installed directly on carpet ing tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance 3 Once positioned secure heater to the floor using screws and mounting holes found on Hea...

Страница 15: ...rew Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert mounting screws through these holes only 3 Remove tape and mounting bracket from wall Attaching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware ...

Страница 16: ...rough bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall 8 Check that the bracket is secure before mounting heater Attaching Wall Hanging Spacers to Heater WARNING Failure to properly install the wall hanging spacers may result in property damage personal injury or even death 1 Locate spacer mounting holes on the lower right left sections of the heater...

Страница 17: ...sure must be a minimum 6 WC for NG and 11 WC for LP with a max pressure of 14 WC If gas line pressure is higher heater regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when connect...

Страница 18: ...G 3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pressure Testing Gas Supply Equal To or less than 1 2 PSIG 3 5kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of t...

Страница 19: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 STOP Read the safety information above on this page 2 Turn off all electric power to the appliance 3 Push in gas control knob slightly and turn clockwise to OFF position See Fig 22a NOTE Knob cannot be t...

Страница 20: ... 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF position and call your service technician or gas supplier If the control knob does not pop up when released stop and immediately and call your service technician or gas supplier 8 Turn on all electric power to the appliance 9 Turn control knob counter cloc...

Страница 21: ...y turned to OFF See Fig 25 Fig 25 Control Knob Position Manual Thermostatic OPERATION INSPECTING BURNERS Check pilot flame pattern daily when in use and at least yearly by a qualified service agency PILOT FLAME PATTERN Fig 26 shows a correct pilot flame pattern Fig 27 shows an incorrect pilot flame pattern The incor rect pilot flame is not touching the thermocouple This will cause the thermocouple...

Страница 22: ...n Off Gas to Appliance page 19 see Troubleshooting pages 23 through 26 Fig 28 Correct Flame Pattern with Control Knob Set to High Flame 5 Fig 29 Incorrect Flame Pattern with Control Knob Set to High Flame 5 1 2 Glass Height 1 2 Glass Height NOTE Yellow colored fames may be caused by airborne dust dander pet hair etc Additionally an excess amount of Mercaptane in the fuel can result in an orange or...

Страница 23: ...ns on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Remove 4 screws 2 screws on each side of the front panel 3 Pull front panel forward 4 Blow air through the ports slots and holes in the burner Also clean the pilot assembly A yellow tip on the pilot flame indicates ...

Страница 24: ...nected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor or ignition module 7 Bad battery 1 Replace ODS 2 Replace ODS 3 Replace ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace piezo ignitor or ignition module 7 Replace the battery Unit shuts off after running a few minutes 1 G...

Страница 25: ...ition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance page 21 or contact customer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 Clean burner orifice see Care and Maintenance page 21 or contact customer service 2 Contact de...

Страница 26: ...er 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate and correct all leaks see Checking Gas Connections page 17 2 Contact customer service Moisture conden sation noticed on windows 1 Not enough combustion ventilation air 1 Refer to Air for Combustion ...

Страница 27: ...is no power to the fan 2 Fan is set to AUTO 3 Fan motor is bad 1 Fan housing or blades are dirty 2 Fan rotation is blocked 3 Defective fan 1 See Cleaning Fan page 22 2 Verify wiring is not in fan path 3 Replace fan 1 Verify fan is plugged in and set to MAN or AUTO 2 Allow 5 10 minutes for fan to engage 3 Replace fan ...

Страница 28: ...28 AQ000229 7 Overheat Limit Switch 1 AQ000042 AQ000042 AQ000042 8 Gas Selector Valve 1 AQ000172 AQ000156 AQ000182 9 Regulator Bracket 1 AQ000015 AQ000015 AQ000015 10 1 NG Regulator Assembly 1 AQ000073 AQ000073 AQ000073 10 2 LP Regulator Assembly 1 AQ000073A AQ000073A AQ000073A 11 Glass Panel 1 AQ000164 AQ000148 AQ000180 12 Glass Panel Retention Bracket 1 AQ000163 AQ000147 AQ000179 13 Wall Mountin...