Alerts and Errors
112/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
No.
Description
E
rr
o
r
8
E08 Load Supply Low
No or too little voltage at terminal X1:1-2
Please check if a permissible voltage from 5 to 24 V is applied to the terminal
E
rr
o
r
9
E09 Load Supply High
Voltage at terminal X1:1-2 too high
Please check if a permissible voltage from 5 to 24 V is applied to the terminal
E
rr
o
r
1
0
E10 Temperature
Power unit is overheated
Please increase the flow of cooling air, lower the ambient temperature and
reduce speed or insert pauses between the movements.
E
rr
o
r
1
1
E11 Following Error
Movement outside the target parameters (comparison of target position and actual position)
If possible, increase the supply voltage or the Motor Current, lower the following error limit, reduce the load, lower
acceleration or speed, or adapt the Closed-Loop control parameters.
E
rr
o
r
1
2
E12 Limit Switch
A limit switch has been tripped
Please check the available stroke, the home position and the positions of the limit switches
E
rr
o
r
1
3
E13 Hall-Sensor
Incorrect Hal sensor data
Please check the Hall Sensor, the wiring and the signal sequence
E
rr
o
r
1
4
E14 Encoder
Incorrect encoder data
Please check the encoder, the wiring and the signal sequence
E
rr
o
r
1
5
E15 Encoder Error Channel A
No or unplausible signal at encoder channel A
Please check the connecting cable for wire breaks or a correct pin assignment of the terminal.
E
rr
o
r
1
6
E16 Encoder Error Channel B
No or unplausible signal at encoder channel B
Please check the connecting cable for wire breaks or a correct pin assignment of the terminal.
E
rr
o
r
1
7
E17 Encoder Error Channel I
No or unplausible signal at encoder channel I
Please check the connecting cable for wire breaks or a correct pin assignment of the terminal.
E
rr
o
r
2
1
E 21 Braking Resistor Overload
Permanent Braking Resistor trigger. Please check the parameter Braking Voltage as well as the value of the
Braking Resistor itself.