HOW TO CONNECT YOUR EXTENDED POWER CABLES
Prepare your tools.
Tools
Specification
Shape
Crimping pliers
MH-14
Connection sleeve (mm)
20x6.5 (HxOD)
Insulation tape
Width 19mm
Contraction tube (mm)
70x8 (LxOD)
As shown in the figure, peel off the shields from the rubber and wire of the power cable.
Peel off 20 mm of cable shields from the pre-installed tube.
For information about the power cable specifications for indoor and outdoor units, refer to the installation
manual.
After peeling off cable wires from the pre-installed tube, insert a contraction tube.
If cable wires are connected without using connecting sleeves, their contact area becomes reduced, or
corrosion develops on the outer surfaces of the wires (copper wires) over a long time. This may cause an
increase in resistance (reduction of passing current) and consequently may result in a fire.
Insert both sides of the core wire of the power cable into the connection sleeve.
Method 1: Push the core wire into the sleeve from both sides.
Method 2: Twist the wire cores together and push it into the sleeve.
Содержание Inuit 6I
Страница 1: ...5 INSTALLATION MANUAL AIR TO WATER HEAT PUMP IGLU INUIT...
Страница 16: ...16 IGLU Inuit 6WTI indoor unit...
Страница 17: ...17 IGLU Inuit 9I outdoor unit IGLU Inuit 9I indoor unit...
Страница 18: ...18 IGLU Inuit 9WTI outdoor unit IGLU Inuit 9WTI indoor unit...
Страница 19: ...19 IGLU Inuit 12I IGLU Inuit 16I outdoor unit IGLU Inuit 12I IGLU Inuit indoor unit...
Страница 20: ...20 IGLU Inuit 12WTI IGLU Inuit 16WTI outdoor unit IGLU Inuit 12WTI IGLU Inuit 16WTI indoor unit...
Страница 27: ...27 SPACE REQUIREMENTS FOR OUTDOOR UNIT WHEN INSTALLING ONE OUTDOOR UNIT...
Страница 31: ...31 WHEN INSTALLING ONE INDOOR UNIT WITHOUT WATER TANK IGLU Inuit 6I IGLU Inuit 9I IGLU Inuit 12I IGLU Inuit 16I...
Страница 32: ...32 WHEN INSTALLING ONE INDOOR UNIT WITHOUT WATER TANK IGLU Inuit 6I IGLU Inuit 9I IGLU Inuit 12I IGLU Inuit 16I...
Страница 43: ...43...