THERMAL DISINFECTION 
 

When a water heater is installed in the system and an electric 
heating element is integrated, the system periodically performs 
thermal  disinfection.  In  the  water  heater  settings  window 

(Window 12)

 you can see information on the time of the next 

thermal disinfection.  

Clicking the 

Thermal Disinfection

 takes you to the disinfection 

time  setting  window 

(Window  13)

,  where  you  can  select  the 

desired disinfection time. 

In the 

Disinfection Time

 window, you can select: 

 

the day of the week or days when you want the  water 
heater to be disinfected; 

 

the time you want the water heater to be disinfected. 

After selecting the days of the week and the preferred time, click 

Set

SYSTEM STATUS 
 

In  the 

System  Status

  window 

(Window  14)

  you  can  see  the 

device settings, such as: 

 

temperature of the glycol delivered to the ground; 

 

temperature of the glycol returning from the ground; 

 

temperature of the supplied heating water; 

 

temperature of the returning heating water. 

STATISTICS SECTION 
 

Clicking  the 

Chart

  icon  on  the  bottom  bar  will  take  you  to  the 

Statistics

.

 Home heating, 

(Window 15)

 where you will see daily, 

weekly,  monthly  or  yearly  energy  consumption  statistics,  heat 
production statistics and coefficient of performance. 

IMPORTANT!

 When you select the annual statistics view, you will see the 

seasonal coefficient of performance

 

(SCOP) below the graph. 

The blue bar shows how many kilowatt-hours of electricity were consumed during the selected period

and black 

 the number of kilowatt-hours of heat produced.

 Click on a column to see its exact value. 

Pressing “

>

” will take you to the water heating statistics window.

 

In the window “

Statistics.  Water  heating.

  (Window 16)

  you  can  see  daily,  weekly, monthly  or  yearly  energy 

consumption and heat production statistics. 

The blue bar shows how many kilowatt-hours of electricity were consumed during the selected period

and black 

 the number of kilowatt-hours of heat produced.

 Click on a column to see its exact value. 

 

Window 13 

Window 14 

Window 15 

Window 16 

Содержание INUIT 6 I

Страница 1: ...USER MANUAL AIR TO WATER HEAT PUMPS IGLU INUIT...

Страница 2: ...LU HOME MOBILE APPLICATION 8 INSTALLATION OF THE APPLICATION 8 LOGIN AND REGISTRATION 9 ADDING A NEW DEVICE 9 MAIN APPLICATION WINDOW 10 TEMPERATURES SETTINGS 11 SYSTEM ERROR AND FAILURE INDICATIONS 1...

Страница 3: ...uries and enjoy the device for a long time CONCEPTS AND SYMBOLS Water heater boiler is a device that performs a very important function it prepares hot water Thermal disinfection thermal shock is a pr...

Страница 4: ...ven in cases where preventive maintenance is not performed regularly Liability and guarantees The manufacturer undertakes to rectify the device free of charge within a period of two years provided tha...

Страница 5: ...coolant leaks it poses risk to people and the environment therefore you must turn off the system make sure the installation room is well ventilated inform the manufacturer s customer service ATTENTION...

Страница 6: ...performs three functions room heating cooling and hot water preparation Comfort at home can be controlled from anywhere in the world HOW DOES AIR TO WATER HEAT PUMP WORK An air to water heat pump wor...

Страница 7: ...ly tilted not laid down The device can be stored at a temperature no lower than 10 C SELECTION OF THE INSTALLATION PLACE When choosing the place of installation of the heat pump mind that the heat pum...

Страница 8: ...ly within a reasonable period of time red heat pump failure operation is stopped IGLU HOME MOBILE APPLICATION IGLU Inuit air to water heat pumps are controlled via the IGLU Home app It allows to contr...

Страница 9: ...hen the login window opens enter the following information Window 3 E mail address Password You can log in by clicking the button If you forgot your password click Remind password ADDING A NEW DEVICE...

Страница 10: ...coefficient of performance COP the ratio of thermal energy produced to electricity consumed to produce that heat IMPORTANT The IGLU Home application is supported by the latest versions of iOS and Andr...

Страница 11: ...t bright triangle the heat pump will continue to operate but every effort should be made to rectify the fault In the event of a system fault dark triangle the heat pump operation will stop By clicking...

Страница 12: ...e error disappears automatically Outdoor temperature sensor Temperature sensor or connection failure Contact customer service When the problem is resolved the error disappears automatically LP low pre...

Страница 13: ...lem is resolved the error disappears automatically Valve configuration Incorrect EEV valve configuration Contact customer service FC not ready The frequency converter is not ready for operation E g oi...

Страница 14: ...nt failure Fault in the power measurement chain of the internal circuit s circulating pump Contact customer service Compressor frequency converter failure Compressor frequency converter failure Detail...

Страница 15: ...talled edit the information of the selected device add new device Clicking the Edit Selection button will take you to the device edit window Window 10 where you can update device address name of the d...

Страница 16: ...the supplied heating water temperature of the returning heating water STATISTICS SECTION Clicking the Chart icon on the bottom bar will take you to the Statistics Home heating Window 15 where you will...

Страница 17: ...In the device status window Window 2 you can turn the device off or on reset faults if any Navigation between windows in the control panel is performed using the and buttons In the water temperature w...

Страница 18: ...pressor rated power Heating A7 W35 1 kW 1 22 1 87 2 59 3 76 Compressor rated power Heating A7 W35 5 kW 1 81 2 73 3 7 5 38 Compressor rated power Cooling A7 W35 6 kW 1 47 2 11 3 10 4 14 Max current wit...

Страница 19: ...72 109 Power network connection values Electrical connections 1F 220 240V 50Hz 3F 400V 50Hz Compressor rated power Heating A7 W35 1 kW 1 22 1 87 2 59 3 76 Compressor rated power Heating A7 W35 5 kW 1...

Страница 20: ...12 WTI IGLU INUIT 16 WTI INFORMATION CONCERNING THE EU DECLARATION OF CONFORMITY The IGLU INUIT heat pumps listed above meet the basic and other essential requirements of the European Union directives...

Отзывы: