Faults

Fault description

The unit will not switch on

Check Trip Switch / Fuse
Check if the plug is connected to mains socket correctly
Check batteries in the remote control

Runs for a short while and then 
switches off

Check if air outlet is blocked, if so remove obstacle  
Check if Delay Timer function has been activated

The unit has been running for a long 
period and then switches off

The overheat protection has been activated to protect the 
motor – turn unit off for a least 10 minutes and then switch 
back on

Runs without cooling in Cool Wind 
mode and Empty Tank Indicator 
blinking

The water tank is empty and needs to be re-filled 
Check if the air filter is dirty – if so, clean
Check if air outlets or inlets are blocked

Water is leaking from unit when 
moving

Check that the tank has not been filled above the MAX line. 
If it has been filled too high then carefully remove some of 
the water until it falls below the MAX line.
Ensure unit is located on a flat and even surface

The honeycomb filter is blocked with 
dust.

Pull down the honeycomb filter and clean it.

The air inlet is blocked with dust

Remove the foreign matter

Maintenance Instruction

The fan requires little maintenance. Do not try to fix it by yourself. Refer it to qualified service personnel 
if service is needed.
1.  Before cleaning and assembling, appliance must be unplugged.
2.  To ensure adequate air circulation to the motor, keep vents at the rear of the motor free of dust. Do 

not disassemble the appliance to remove dust.

3.  Please wipe the exterior parts with a soft cloth soaking a mild detergent.
4.  Do not use any abrasive detergent or solvents to avoid scratching the surface. Do not use any of the 

following as a cleaner: gasoline, thinner.

5.  Do not allow water or any other liquid into the motor housing or interior parts.

Cleaning

1.  Be sure to unplug from the electrical supply source before cleaning.
2.  Plastic parts should be cleaned with a soft cloth moisten with mild soap. Thoroughly remove soap film 

with dry cloth.

Содержание IG9706

Страница 1: ...instructions carefully before use and retain for future reference Before switching on your appliance always check for any damage which may have been caused in transit IG9706 Batch code 5 Litre Air Co...

Страница 2: ...fety Instructions 3 5 Appliance Overview 6 Operating Instructions 6 10 Cleaning and Maintenance 10 11 Trouble Shooting Guide 12 Disposal Information 13 Fuse Replacement 13 Terms and Conditions and War...

Страница 3: ...illing and cleaning 5 Prior to cleaning or other maintenance the appliance must be disconnected from the supply mains 6 Correct Disposal of this product This marking indicates that this product should...

Страница 4: ...uring humidification the total water level in the tank shall be controlled and shall not be below MIN minimum scale 15 After the water tank is filled with water do not tilt or collide with the unit wh...

Страница 5: ...Please note that high levels of humidity in a room can lead to build up of mould Humidity levels should always be controlled inside the home wherever possible to prevent this from happening 28 Do not...

Страница 6: ...ith water and cleaning Always make sure that the water pump module is fixed securely in place before turning on the air cooler If the water pump module is not securely fastened it can affect the perfo...

Страница 7: ...s anticlockwise to release the water pump module from the water tank including the water pipe 2 Once the water pump module has been detached carefully remove the water tank from the unit so that it ca...

Страница 8: ...ction 5 Ice blocks can be used to replace the frozen ice box to create the same cooling effect 6 Ensure that the water level in the water tank doesn t exceed the MAX maximum line on the front of the w...

Страница 9: ...wind the indicator light is on Delay Timer Set a delay timer for the air cooler to automatically shut down after a selected period of time Press the button repeatedly to cycle through delay shutdown...

Страница 10: ...te it is shown by NOTE On the unit control panel selects Cool Wind On the remote this same function is shown by NOTE Disconnect the power before cleaning the product Clean after the product is shut do...

Страница 11: ...detergent and a soft brush scrub the honeycomb filter with clean water and then leave to dry fully before placing back into the filter support 4 Re install the honeycomb filter support once all piece...

Страница 12: ...unit when moving Check that the tank has not been filled above the MAX line If it has been filled too high then carefully remove some of the water until it falls below the MAX line Ensure unit is loca...

Страница 13: ...pact on human health and the environment The crossed out wheeled bin symbol on the product reminds you of your obligation that when you dispose of the appliance it must be separately collected Consume...

Страница 14: ...ccessories or consumable parts that require replacement under normal use This includes shelving dials filters belts and trays etc In the unlikely event of a breakdown please refer to the Troubleshooti...

Страница 15: ...his means that in the unlikely event you develop a fault or problem with your product we will happily repair or replace the item free of charge To qualify for the 2 year warranty you must register you...

Страница 16: ...claimer Igenix operate a policy of continual improvement and development We therefore reserve the right to change alter the specification and appearance of our appliances without prior notice All diag...

Отзывы: