  Fully open valve for purging. The pre-pressed gland packing can lose its 

denseness due to a longer storage (see chapter 10.4) 

  Close valve. 

 

 

10.4 Maintenance 

 

Before carrying out maintenance works on drain valve, unit has to be 

pressureless and empty! 

Severe burns and scaldings on the whole body are possible! 

 

Re-tightening of gland packing: 

 

  If a valve is leaky, tighten screw cap (8) with open-end wrench (SW27) 

 

clockwisely until valve is tight. Spindle (4) has to stay movable. 

  Replace gland packing if re-tightening of packing was not successful. 

 

Replacement of packing: 

 

  Screw off cap nut (13) and remove handwheel (11). 

 

Unscrew

 

upper part of valve (10). 

 

Remove screw cap

 

(8) and stuffing box (7). 

 

Remove spindle with cone (4) upwards. 

  Push out gland packing (6) with scraper rings (5) from top and clean packing 

space. 

 

 

Assembly: 

 

 

Grease spindle thread, insert from top and firmly tighten screws. 

 

Place new greased packing with scraper rings (5). 

 

Insert stuffing box (7). 

 

Tighten screw cap (8). 

 

Insert new sealing ring (9). 

 

Grease thread of upper part of valve (10), screw in and tighten with 
tightening torque 

M

d

 = 220 Nm

  Place handwheel (11) and tighten cap nut (13). 

 

Replacement of complete upper part: 

 

 

For dismounting of component parts see “Replacement of packing” 

 

Unscrew seat (3) with hexagon socket wrench SW11. 

  Grease seat thread, screw in and tighten with tightening torque 

M

d

 = 55 Nm

 

Replace complete upper part. 

 

Place new spindle. 

  For assembly of component parts see above. 

 

 

11. Spare parts 

 

Always indicate article no. and serial no. (indicated on the identification plate) in case of 
spare parts order! 

 

11.1  Magnetic level gauge 

Содержание NA7-50

Страница 1: ......

Страница 2: ...limits 8 4 5 Corrosion resistance 8 4 6 Identification plate Marking 8 5 Construction 9 6 Assembly 9 6 1 Version with flange 9 6 2 Version with welding end 10 6 3 Heat treatment of weldseams 10 6 4 Fl...

Страница 3: ...9 2 Tightening torques 14 10 Drain valve 14 10 1 Construction 14 10 2 Assembly 15 10 3 Commissioning 16 10 4 Maintenance 16 11 Spare parts 17 11 1 Magnetic level gauge 17 11 2 Drain valve 17 12 Decomm...

Страница 4: ...n passing the unit to a third party these mounting and operating instructions must be enclosed in the national language of this third party Only skilled and qualified personnel with special work order...

Страница 5: ...In case of opening and disassembling the unit residual medium can escape Further evaporation is also possible on pressureless plant Sharp edged interior parts can cause cutting damages on the hands A...

Страница 6: ...uipment also possible for existing devices Magnetic switch Primary element MRK Drain valve 3 2 System description The level gauge indicates the level in the boiler indirectly 3 3 Function The unit wor...

Страница 7: ...e Flange with vent flange Possible drain connections Flange with drain flange Flange with drain valve To indicate a range 2 6 m it is necessary to use 2 or more superposed indicating ledges For level...

Страница 8: ...ess steel for low medium density the float is made of titan 4 4 Application limits 4 5 Corrosion resistance The safety of the unit is not influenced by corrosion if it is used as intended 4 6 Identifi...

Страница 9: ...Check mating dimensions between instrument nozzle and boiler nozzle Make sure that there are no magnetic materials or magnetic field generators in close proximity of the standpipe within 100 mm 6 1 V...

Страница 10: ...h top heavy side upwards into standpipe top heavy side with colour marking Tighten cover flange 2 3 and associated gaskets 2 2 with standpipe using successively opposite diagonal tightening see chapte...

Страница 11: ...nologies and of the local network operators for the installation to be provided by the customer Only use cables that are suitable for the operating range Observe the switching time of the magnetic swi...

Страница 12: ...rating condition and adjust the height if necessary 8 3 Commissioning of unit if boiler is already in operating condition Close drain valve A plug 6 see sketch chapter 5 Open slowly shutoff valve W an...

Страница 13: ...valve A plug 6 unit is drained Caution When dismounting residual medium may escape and further evaporation is also possible Remove cover flange 2 3 Remove float and clean standpipe and float Insert fl...

Страница 14: ...m 10 Drain valve 10 1 Construction AV500 AV520 Male thread G on input side Output side with cutting ring connection 12 as per DIN 2353 DS12 AV540 AV550 Male thread G on input side Output side with wel...

Страница 15: ...ion 10 2 Assembly Ensure that drain piping has free outlet to atmosphere and is protected from pressure peaks Firmly screw on drain valve with sealing ring 2 on existing unit Cutting ring connection A...

Страница 16: ...ndle with cone 4 upwards Push out gland packing 6 with scraper rings 5 from top and clean packing space Assembly Grease spindle thread insert from top and firmly tighten screws Place new greased packi...

Страница 17: ...0128 7 Screw plug 40 03794 Sealing 40 00127 4 Magnetic switch 15 03037 5 Primary element MRK depending on the order 2 1 Float depending on the order Pos no Designation Allowable pressure PS bar Articl...

Страница 18: ...al regulations for waste disposal 13 Supplement Warranty We accord a warranty period of 24 month on our products A condition for that is the appropriate treatment according to these mounting and opera...

Страница 19: ...19 IGEMA GmbH Antwerpener Str 1 D 48163 Germany Tel 49 25 01 9 24 24 0 Fax 49 25 01 9 24 24 99 info igema com www igema com...

Отзывы: