5
UK
►
Install the units according to the applicable rules and regulations�
►
Ensure that the system is free of pressure during installation�
►
Protect the housing against contact with flammable substances and uninten-
tional contact� To do so, equip the units with suitable protection (e�g� protective
cover)�
►
Do not press the pushbuttons manually� instead use another object (e�g�
ballpoint pen)�
3 Functions and features
The unit monitors liquid media� It detects the 3 process categories volumetric flow,
consumed quantity, medium temperature�
Pressure Equipment Directive (PED)
The units comply with the Pressure Equipment Directive and are designed and
manufactured for group 2 fluids in accordance with the sound engineering prac-
tice� Use of group 1 fluids on request�
Application area
Conductive liquids with the following properties:
•
Conductivity: ≥ 20 µS/cm
• Viscosity: < 70 mm
2
/s at 40 °C; < 70 cSt at 104 °F
4 Function
• The unit detects the flow based on the magnetic-inductive volumetric flow
measuring principle�
• The unit also detects the medium temperature�
• It features an IO-Link interface�
• The unit displays the current process value�