![IFM PK6730 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/ifm/pk6730/pk6730_operating-instructions_620732005.webp)
5
UK
6 Setting / Operation
1:
locking ring
2: setting rings (manually adjustable after unlocking)
3: green LED: supply voltage O.K.
4:
process connection R¼ A; tightening torque 25 Nm
5:
setting marks
6: yellow LED: Set value reached, OUT1 = ON / OUT2 = OFF
7:
internal thread M5
•
Minimum distance between Set and Reset = 2% of the final value of the
measuring range�
•
To obtain the setting accuracy: Set the rings to the minimum value, then set the
requested value�
More information at www�ifm�com