ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
LED, buzzer, visualisation
Edit input fields in the visualisation
397
12.3.1
INPUT_INT
3220
Unit type = function block (FB)
Contained in the library:
ifm_PDM_INPUT_Vxxyyzz.Lib
Available for the following devices:
- PDM360: CR1050, CR1051, CR1060
- PDM360compact: CR1052, CR1053, CR1055, CR1056
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
3328
INPUT_INT supports up to 6 input fields which can be assigned to 6 different objects in the
visualisation. The input objects are parameterised with the internal variables FIELD1...FIELD6,
COLOR_FIELD1...COLOR_FIELD6 and VALUE_FIELD1...VALUE_FIELD6.
The FB is an alternative to the input function integrated in CoDeSys and more flexible compared to the
CoDeSys input function.
The FB contains no visualisation elements.